Analysis and detection of turn-to-turn short circuit fault in a permanent magnet Vernier generator based on modified winding function

被引:8
|
作者
Arianborna, MohammadHossein [1 ]
Faiz, Jawad [1 ]
Ghods, Mehrage [1 ]
Bazrafshan, Mohammad [1 ]
机构
[1] Univ Tehran, Sch Elect & Comp Engn, Coll Engn, Ctr Excellence Appl Electromagnet Syst, Tehran, Iran
关键词
linear machines; modified winding function generator; permanent magnet Vernier turn-turn short circuit fault; Vernier generator; SYNCHRONOUS MACHINE; MOTORS; PMSM; ECCENTRICITY;
D O I
10.1049/elp2.12127
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Operation of Vernier machines is based on flux modulation. They have some advantages including maintaining the rated torque in motor applications and the rated output power in generator applications at low speeds, high torque density and relatively low torque ripple due to their magnetic gear property and fault-tolerance. In recent years, the motor with various topologies has been developed for different applications. Therefore, analysing and monitoring different faults is essential in the design and implementation stages. This study has two main purposes. First, to introduce an accurate frequency index independent of load variations for detecting the turn-to-turn short circuit (TTSC) faults in the stator windings of a permanent magnet Vernier machine. Second, modelling the machine in a healthy condition and in the presence of TTSC faults to investigate its effect on machine performance and output characteristics. An analytical model is presented using the modified winding function theory under the TTSC fault by taking into account the effect of stator slots which enhances the accuracy of the air-gap permeance function estimation. In the process of calculating the fault index, frequency components of the output characteristics of the machine are obtained from the mathematical equations of the magnetic field. It is shown that the proposed indicators are robust against load variations.
引用
下载
收藏
页码:1630 / 1647
页数:18
相关论文
共 50 条
  • [41] Feasibility Study on the Detection of Turn-to-Turn Fault Severity in the Transformer Winding by Frequency Response Analysis and Numerical Indices
    Samimi, Mohammad Hamed
    Faiz, Jawad
    Parchini, Jafar Ghasemi
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023, 51 (09) : 856 - 870
  • [42] A virtual instrument for the rotor winding inter-turn short circuit fault of generator
    Wan Shuting
    Lv Luyong
    Liu Qing
    Xv Yan
    Li Heming
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 270 - +
  • [43] Localization of Turn-to-Turn Fault in Transformers Using Artificial Neural Networks and Winding Transfer Function
    Faridi, Mohsen
    Kharezi, Mohammad
    Rahimpour, Ebrahim
    Mirzaei, Hasan Reza
    Akbari, Asghar
    PROCEEDINGS OF THE 2010 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2010), 2010,
  • [44] Analysis of Stator Winding Inter-turn Short-circuit Fault in Interior and Surface Mounted Permanent Magnet Traction Machines
    Lai, Chunyan
    Balamurali, Aiswarya
    Bousaba, Vicki
    Iyer, K. Lakshmi Varaha
    Kar, Narayan C.
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC), 2014,
  • [45] Analysis on unbalanced magnetic pull generated by turn-to-turn short circuit of rotor windings within turbine generator
    Wu, Yu-Cai
    Li, Yong-Gang
    Feng, Wen-Zong
    Zhang, Wen-Jing
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2015, 19 (03): : 37 - 44
  • [46] Analysis of Stator Winding Inter-turn Short-circuit Fault in Interior and Surface Mounted Permanent Magnet Traction Machines
    Lai, Chunyan
    Balamurali, Aiswarya
    Bousaba, Vicki
    Iyer, K. Lakshmi Varaha
    Kar, Narayan C.
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC), 2014,
  • [47] Intern-turn fault modeling and diagnosis in permanent magnet vernier machine using modified magnetic equivalent circuit method
    Rostami, Mohsen
    Naderi, Peyman
    Shiri, Abbas
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2022, 41 (01) : 410 - 426
  • [48] Winding turn-to-turn short-circuit diagnosis using FRA method: sensitivity of measurement configuration
    Devadiga, Anurag A.
    Harid, Noureddine
    Griffiths, Huw
    Al Sayari, Naji
    Barkat, Braham
    Jayaram, Sheshakamal
    Ikeda, Hisatoshi
    Koshizuka, Tadashi
    Taniguchi, Yasuhiko
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (01) : 17 - 24
  • [49] Anti-Interference and Location Performance for Turn-to-Turn Short Circuit Detection in Turbo-Generator Rotor Windings
    Wu, Yucai
    Ma, Guanhua
    ENERGIES, 2019, 12 (07)
  • [50] Permanent Magnet Synchronous Machines Inter-Turn Short Circuit Fault Detection by Means of Model-Based Residual Analysis
    Alvarez-Gonzalez, Fernando
    Griffo, Antonio
    Wang, Bo
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 647 - 652