Comparison between non-destructive evaluation techniques and integrated fiber optic health monitoring systems for composite sandwich structures

被引:1
|
作者
Balageas, D
Bourasseau, S
Dupont, M
Bocherens, E
Dewynter-Marty, V
Ferdinand, P
机构
[1] Off Natl Etud & Rech Aerosp, Dept Mecan Solide & Endommagement, F-92322 Chatillon, France
[2] AIA Cuers Pierrefeu, F-83800 Toulon Naval, France
[3] Ctr Etud Saclay, CEA Technol Avancees, LETI, Dept Electron & Instrumentat Nucl SPE, F-91191 Gif Sur Yvette, France
关键词
D O I
10.1177/104538900772664594
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Non-Destructive Evaluation (NDE) methods have been adapted to composite sandwich structures in order to detect damage, in particular impact induced damage. Using three coupons representative of radome structures, several techniques were tested: ultrasonics, the Electromagnetic/InfraRed method (EMIR), stimulated shearography and stimulated infrared thermography. The extension of the measured damaged area was taken as a criterion, showing that stimulated shearography and ultrasound are the most sensitive methods. Moreover, two integrated Health Monitoring Systems (HMS) were tested, based on the one hand on microbending sensitive fibres and Optical Time Domain Reflectometry (OTDR), and on the other hand on Fibre Bragg Grating (FBG) sensors. The experiments demonstrated that HMS can detect damage with sensitivity comparable to that of the external NDE techniques.
引用
收藏
页码:426 / 437
页数:12
相关论文
共 50 条
  • [32] Structural Health Monitoring in Composite Structures by Fiber-Optic Sensors
    Guemes, Alfredo
    Fernandez-Lopez, Antonio
    Diaz-Maroto, Patricia F.
    Lozano, Angel
    Sierra-Perez, Julian
    SENSORS, 2018, 18 (04)
  • [33] Non-destructive Evaluation of GFRP-Wood Sandwich Structure Composite using Terahertz Imaging
    Harikrishnan
    Devi, Nirmala
    Ray, Shaumik
    Rajagopal, Prabhu
    Balasubramanian, Krishnan
    Pesala, Bala
    TERAHERTZ, RF, MILLIMETER, AND SUBMILLIMETER-WAVE TECHNOLOGY AND APPLICATIONS XI, 2018, 10531
  • [34] Development of a health monitoring system for civil structures using a level IV non-destructive damage evaluation method
    Sikorsky, C
    STRUCTURAL HEALTH MONTORING 2000, 1999, : 68 - 81
  • [35] Quantitative non-destructive evaluation of advanced composite panels using optical interferometric techniques
    Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
    不详
    Insight Non Destr Test Cond Monit, 4 (244-249):
  • [36] Garisenda Tower in Bologna (Italy): health monitoring by different non-destructive testing techniques
    Di Tommaso, Angelo
    Olivetti, Gian Carlo
    Lacidogna, Giuseppe
    Invernizzi, Stefano
    Borla, Oscar
    Carpinteri, Alberto
    INTERNATIONAL JOURNAL OF MASONRY RESEARCH AND INNOVATION, 2024, 9 (1-2) : 54 - 66
  • [37] Quantitative non-destructive evaluation of advanced composite panels using optical interferometric techniques
    Lam, CL
    Lalor, MJ
    Burton, DR
    Leung, TP
    INSIGHT, 1999, 41 (04) : 244 - 249
  • [38] Industrial Age non-destructive evaluation to Information Age structural health monitoring
    Derriso, Mark M.
    DeSimio, Martin P.
    McCurry, Charles D.
    Kabban, Christine M. Schubert
    Olson, Steven E.
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2014, 13 (06): : 591 - 600
  • [39] Application of optical interferometric techniques for non-destructive evaluation of novel "green" composite materials
    Russo, Pietro
    Simeoli, Giorgio
    Cimino, Francesca
    Pagliarulo, Vito
    Bianco, Vittorio
    Ruggiero, Berardo
    Ferraro, Pietro
    NONDESTRUCTIVE CHARACTERIZATION AND MONITORING OF ADVANCED MATERIALS, AEROSPACE, CIVIL INFRASTRUCTURE, AND TRANSPORTATION XII, 2018, 10599
  • [40] Non-destructive evaluation of stacking sequence in textile composite: different techniques and experimental verification
    Saboktakin, A.
    Vu-Khanh, T.
    Bonnefon, Y.
    ASSEMBLY AUTOMATION, 2014, 34 (03) : 264 - 274