Molecularly imprinted coated graphene oxide solid-phase extraction monolithic capillary column for selective extraction and sensitive determination of phloxine B in coffee bean

被引:36
|
作者
Zhai, Haiyun [1 ]
Su, Zihao [1 ]
Chen, Zuanguang [2 ]
Liu, Zhenping [1 ]
Yuan, Kaisong [1 ]
Huang, Lu [1 ]
机构
[1] Guangdong Pharmaceut Univ, Coll Pharm, Guangzhou 510006, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Sch Pharmaceut Sci, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Phloxine B; Graphene oxide-molecularly imprinted polymers; Solid-phase extraction; In situ polymerization; Monolithic capillary column; LIQUID-CHROMATOGRAPHY; POLYMER; URANINE; SAMPLES; WATER; MICROEXTRACTION; RECOGNITION; URINE;
D O I
10.1016/j.aca.2015.01.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed to sensitively determine phloxine B in coffee bean by molecularly imprinted polymers (MIPs) coated graphene oxide (GO) solid-phase extraction (GO-MISPE) coupled with high-performance liquid chromatography and laser-induced fluorescence detection (HPLC-LIF). The GO-MISPE capillary monolithic column was prepared by water-bath in situ polymerization, using GO as supporting material, phloxine B, methacrylic acid (MAA), and ethylene dimethacrylate (EDMA) as template, functional monomer, and cross-linker, respectively. The properties of the homemade GO-MISPE capillary monolithic column, including capacity and specificity, were investigated under optimized conditions. The GO-MIPs were characterized by scanning electron microscopy (SEM) and Fourier transform-infrared spectroscopy (FT-IR). The mean recoveries of phloxine B in coffee bean ranged from 89.5% to 91.4% and the intra-day and inter-day relative standard deviation (RSD) values all ranged from 3.6% to 4.7%. Good linearity was obtained over 0.001-2.0 mg mL (1) (r = 0.9995) with the detection limit (S/N = 3) of 0.075 ng mL (1). Under the selected conditions, enrichment factors of over 90-fold were obtained and extraction on the monolithic column effectively cleaned up the coffee bean matrix. The results demonstrated that the proposed GO-MISPE HPLC-LIF method can be applied to sensitively determine phloxine B in coffee bean. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 21
页数:6
相关论文
共 50 条
  • [41] Selective Determination of Chloramphenicol in Milk Samples by the Solid-Phase Extraction Based on Dummy Molecularly Imprinted Polymer
    Fengnian Zhao
    Yongxin She
    Chao Zhang
    Shanshan Wang
    Xinwei Du
    Fen Jin
    Maojun Jin
    Hua Shao
    Lufei Zheng
    Jing Wang
    Food Analytical Methods, 2017, 10 : 2566 - 2575
  • [42] Dummy molecularly imprinted microbeads as solid-phase extraction material for selective determination of phthalate esters in water
    Ozer, Elif Tumay
    Osman, Bilgen
    Yazici, Tugce
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1500 : 53 - 60
  • [43] Molecularly imprinted solid-phase extraction for the selective determination of valnemulin in feeds with high performance liquid chromatography
    Guo, Hongbin
    Liu, Kaiyong
    Liu, Yahong
    Fang, Binghu
    Liu, Min
    He, Limin
    Zeng, Zhenling
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (02): : 181 - 185
  • [44] Synthesis and application of molecularly imprinted polymer on selective solid-phase extraction for the determination of monosulfuron residue in soil
    Dong, XC
    Wang, N
    Wang, SL
    Zhang, XW
    Fan, ZJ
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1057 (1-2) : 13 - 19
  • [45] Molecularly imprinted solid-phase extraction coupled with HPLC for the selective determination of monobutyl phthalate in bottled water
    Qi, Peipei
    Wang, Jincheng
    Li, Yun
    Su, Fan
    Jin, Jing
    Chen, Jiping
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (19) : 2712 - 2718
  • [46] PREPARATION AND CHARACTERIZATION OF MOLECULARLY IMPRINTED MONOLITHIC COLUMN FOR ON-LINE SOLID-PHASE EXTRACTION COUPLED WITH HPLC FOR DETERMINATION OF THE FLUOROQUINOLONE RESIDUES IN HONEY SAMPLES
    Lv, Yun-Kai
    Jia, Cui-Ling
    Zhang, Jing-Qi
    Li, Pan
    Sun, Han-Wen
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (02) : 249 - 260
  • [47] A new molecularly imprinted polymer for selective extraction of cotinine from urine samples by solid-phase extraction
    Jun Yang
    Yan Hu
    Ji-Bao Cai
    Xiao-Lan Zhu
    Qing-De Su
    Analytical and Bioanalytical Chemistry, 2006, 384 : 761 - 768
  • [48] A new molecularly imprinted polymer for the selective extraction of naproxen from urine samples by solid-phase extraction
    Caro, E
    Marcé, RM
    Cormack, PAG
    Sherrington, DC
    Borrull, F
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 137 - 143
  • [49] Selective Determination of Melamine in Aqueous Medium by Molecularly Imprinted Solid Phase Extraction
    Curcio, Manuela
    Puoci, Francesco
    Cirillo, Giuseppe
    Iemma, Francesca
    Spizzirri, Umile Gianfranco
    Picci, Nevio
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (22) : 11883 - 11887
  • [50] Development of a molecularly imprinted solid-phase extraction sorbent for the selective extraction of telmisartan from human urine
    Yilmaz, Huma
    Basan, Hasan
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (08) : 1433 - 1439