Using a Multiport Pitot tube in circulating water flow measurements

被引:0
|
作者
Figueroa Ibarra, Luis R. [1 ]
Rodriguez Martinez, J. Hugo [1 ]
Santabarbara Botello, Marcelino [1 ]
机构
[1] Inst Invest Elect, Dept Proc Term, Cuernavaca 62490, Morelos, Mexico
关键词
Multiport Pitot tube; water flow rate measurement;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper details the design of a Pitot tube used for water flow rate measurements in large pipes. The paper describes first the nowadays commonly used device (simplex pitot), based on standard CTI Code ATC-105 from Cooling Tower Institute [1]. The disadvantages of the simplex pitot are pointed out, and the detailed description of the proposed device (multiport pitot) is explained. The Multiport Pitot, which design is also based on norm ATC-105, is able to perform real-time measurements. The paper also includes the results obtained from the water flow rate measurements made in the cooling system of a thermal power plant in Mexico. These measurement results were compared to simulation results obtained with a computational commercial simulation tool.
引用
收藏
页码:749 / 756
页数:8
相关论文
共 50 条
  • [21] Effect of the Pitot Tube on Measurements in Supersonic Axisymmetric Underexpanded Microjets
    Mironov, Sergey G.
    Aniskin, Vladimir M.
    Korotaeva, Tatiana A.
    Tsyryulnikov, Ivan S.
    MICROMACHINES, 2019, 10 (04)
  • [22] Application of Pitot-tube method in the flow field calibrations of low speed water tunnel
    Li, Yan
    Wang, Hai-Wen
    Guo, Hui
    Shiyan Liuti Lixue/Journal of Experiments in Fluid Mechanics, 2009, 23 (03): : 104 - 107
  • [23] CORRECTION OF PRANDTLS PITOT TUBE VALUES IN FREE TURBULENT FLOW
    HACKESCH.M
    MASCHINENBAU TECHNIK, 1968, 17 (04): : 197 - &
  • [24] Estimation of the correction term of pitot tube measurements in unsteady (gusty) flows
    Chevula, Sreenadh
    Sanz-Andres, Angel
    Franchini, Sebastian
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 46 : 179 - 188
  • [25] ANOMALOUS PITOT TUBE AND HOT FILM MEASUREMENTS IN DILUTE POLYMER SOLUTIONS
    SMITH, KA
    MERRILL, EW
    MICKLEY, HS
    VIRK, PS
    CHEMICAL ENGINEERING SCIENCE, 1967, 22 (04) : 619 - &
  • [26] Using a Smartphone Pressure Sensor as Pitot Tube Speedometer
    Dorsel, Dominik
    Staacks, Sebastian
    Heinke, Heidrun
    Stampfer, Christoph
    PHYSICS TEACHER, 2022, 60 (04): : 273 - 275
  • [27] The impact of geometric parameters of a S-type Pitot tube on the flow velocity measurements for greenhouse gas emission monitoring
    Doan Trang Nguyen
    Choi, Yong Moon
    Lee, Saeng Hee
    Kang, Woong
    FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 67 : 10 - 22
  • [28] Simulation research for modelling the calibration of the flow meter with averaging pitot tube
    Gondek, Antoni
    Niezgoda-Zelasko, Beata
    Zelasko, Jerzy
    Inzynieria Chemiczna i Procesowa, 2002, 22 (04): : 633 - 644
  • [29] Improving accuracy of averaging Pitot tube flow sensor at downstream of elbow
    Sun, Lijun
    Sun, Chao
    Qiu, Xiang
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2014, 47 (03): : 212 - 217
  • [30] 3D numerical simulation of flow and temperature on Pitot tube
    Wang Ying
    Li Dayong
    Li Wenbo
    PROCEEDINGS OF THE 5TH IASME/WSEAS INTERNATIONAL CONFERENCE ON FLUID MECHANICS AND AERODYNAMICS (FMA '07), 2007, : 306 - 309