In Vivo Dosimetry in Total Body Irradiation

被引:1
|
作者
Llanes Veiga, Eilen [1 ]
Alfonso Laguardia, Rodolfo [2 ]
Caballero Pinelo, Roberto [3 ]
机构
[1] Inst Oncol & Radiobiol, Havana, Cuba
[2] Super Inst Technol & Appl Sci, Havana, Cuba
[3] Hermanos Ameijeiras Hosp, Havana, Cuba
关键词
In vivo dosimetry; Total body irradiation; Semiconductor diodes; Radiochromic films;
D O I
10.1007/978-981-10-9038-7_12
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total Body Irradiation (TBI) is a radiotherapy technique that consists of irradiating homogeneously the whole patients body and it is characterized by extended source to surface distances and the use of large irradiation fields. The limitations of the available input data and inherent problems with the calculation procedures make it very difficult to accurately determine the dose distributions in TBI. For these reasons, it is highly recommended to use In Vivo Dosimetry (IVD), to guarantee the quality of TBI treatments as a direct measurement of the delivered dose. An IVD QA system was implemented based on semiconductor diodes and radiochromic films. For the commissioning of the system, both detector types were calibrated independently. This guarantees the traceability of the measurements. An assessment was made on the sources of uncertainties. A tolerance level of +/- 10% was established for the combined contribution of both computational and experimental uncertainties. An experiment to a phantom was carried out to simulate a clinical TBI procedure. In this way, the calibration of the dosimetry system was corroborated. Finally, the IVD system was applied in TBI of three real patients. The discrepancies obtained between the prescribed and measured doses were below the established tolerance level of +/- 10%.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 50 条
  • [31] Robustness and In Vivo Dosimetry for Total Marrow Irradiation With VMAT
    Mancosu, P.
    Scorsetti, M.
    Navarria, P.
    Castagna, L.
    Gaudino, A.
    Sarina, B.
    Reggiori, G.
    Palumbo, V.
    Stravato, A.
    Lobefalo, F.
    Maggi, G.
    Tomatis, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S936 - S937
  • [32] Evaluation of Total Body Irradiation Technique Using 20 Diodes In-Vivo Dosimetry System
    Zhou, P.
    Kiszka, D.
    Zhang, H.
    Jia, Y.
    Desrosiers, C.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [33] Clinical use of Gafchromic EBT4 film for in vivo dosimetry for total body irradiation
    Draeger, Emily
    Guan, Fada
    Lee, Min-Young
    Han, Dae Yup
    Donahue, William
    Chen, Zhe
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (03):
  • [34] Total body irradiation with an arc and a gravity-oriented compensator: Clinical implementation and in vivo dosimetry
    Fontenla, DP
    Kapulsky, A
    Mullokandov, E
    Lai, PP
    Vikram, B
    RADIOLOGY, 1997, 205 : 694 - 694
  • [35] In-vivo dosimetry from total body irradiation patients (2000–2006): results and analysis
    C. M. Lancaster
    J. C. Crosbie
    S. R. Davis
    Australasian Physics & Engineering Sciences in Medicine, 2008, 31 : 191 - 195
  • [36] Pediatric Total Body Irradiation Calculations and In-Vivo Dosimetry Using Diodes and OSLD's
    Chungbin, S.
    Fatyga, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 283 - 283
  • [37] Patterns of Patient Specific Dosimetry in Total Body Irradiation
    Akino, Y.
    McMullen, K.
    Das, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3769 - 3769
  • [38] Patterns of patient specific dosimetry in total body irradiation
    Akino, Yuichi
    McMullen, Kevin P.
    Das, Indra J.
    MEDICAL PHYSICS, 2013, 40 (04)
  • [39] INVIVO DOSIMETRY DURING TOTAL-BODY IRRADIATION
    FAUSER, L
    CHRIST, G
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1985, 143 (06): : 701 - 704
  • [40] TECHNIQUE AND DOSIMETRY OF TOTAL-BODY IRRADIATION IN BASEL
    ROTH, J
    STRAHLENTHERAPIE UND ONKOLOGIE, 1987, 163 (04): : 233 - 234