Assessment of ECG Signal Quality After Compression

被引:2
|
作者
Nemcova, Andrea [1 ]
Vitek, Martin [1 ]
Marsanova, Lucie [1 ]
Smisek, Radovan [1 ,2 ]
Smital, Lukas [1 ]
机构
[1] Brno Univ Technol, Dept Biomed Engn, Fac Elect Engn & Commun, Tech 12, Brno 61600, Czech Republic
[2] Czech Acad Sci, Inst Sci Instruments, Kralovopolska 147, Brno 61264, Czech Republic
关键词
Compression; ECG; Electrocardiogram; Quality assessment; Quality evaluation; SPIHT; CSE database;
D O I
10.1007/978-981-10-9038-7_31
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Highly efficient lossy compression algorithms for ECG signals are connected with distortion of the signals; lossy compression is a compromise between compression efficiency and signal quality. It is recommended to express this relation using rate-distortion curve. To decide whether the signal is suitable for further analysis, it is necessary to assess its quality after reconstruction. Although there exist many methods for quality assessment, neither of them is standardized or unified. The methods usually do not offer any information about their acceptable values. This paper introduces 10 new methods for signal quality assessment and their limits. Four methods are simple (entropy, mean, median, spectra similarity), two are based on delineation of ECG (SiP, SiPA), and four combine dynamic time warping, delineation, and calculation of distance (DTWdist, DTWpmfp1, DTWpmfp2, pmfp). These methods are tested on the whole standard CSE database using compression algorithm based on wavelet transform and set partitioning in hierarchical trees. The signals were compressed with various efficiency expressed by average value length (avL). Two ECG experts divided the compressed signals into three quality groups: perfect quality, good quality, not evaluable ECG. Owing to the experts' ECG classification, we set the range of avL for each quality group. Based on this, we determined corresponding ranges of new methods' values. Based on the trend of rate-distortion curve, its sensitivity, variability, their ratio at important boundary avL = 0.8 bps, and computational demand of the methods, we recommend four methods for further use.
引用
收藏
页码:169 / 173
页数:5
相关论文
共 50 条
  • [31] Modified SPIHT wavelet compression for ECG signal
    Singh, M.
    Kumar, V.
    Saxena, S.C.
    Journal of Medical Engineering and Technology, 2007, 31 (01): : 29 - 35
  • [32] ECG compression with retrieved quality guaranteed
    Blanco-Velasco, M
    Cruz-Roldán, E
    Godino-Llorente, JI
    Barner, KE
    ELECTRONICS LETTERS, 2004, 40 (23) : 1466 - 1467
  • [33] Signal Quality Assessment and Lightweight QRS Detection for Wearable ECG SmartVest System
    Liu, Chengyu
    Zhang, Xiangyu
    Zhao, Lina
    Liu, Feifei
    Chen, Xingwen
    Yao, Yingjia
    Li, Jianqing
    IEEE INTERNET OF THINGS JOURNAL, 2019, 6 (02) : 1363 - 1374
  • [34] Diagnostic quality assured ECG signal compression with selection of appropriate mother wavelet for minimal distortion
    Jha, Chandan Kumar
    Kolekar, Maheskumar H.
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (04) : 500 - 508
  • [35] A low computational complexity algorithm for ECG signal compression
    Blanco-Velasco, M
    Cruz-Roldán, F
    López-Ferreras, F
    Bravo-Santos, A
    Martínez-Muñoz, D
    MEDICAL ENGINEERING & PHYSICS, 2004, 26 (07) : 553 - 568
  • [36] FPGA custom DSP for ECG signal analysis and compression
    Peiró, MM
    Ballester, F
    Paya, G
    Belenguer, J
    Colom, R
    Gadea, R
    FIELD-PROGRAMMABLE LOGIC AND APPLICATIONS, PROCEEDINGS, 2004, 3203 : 954 - 958
  • [38] ECG signal compression using analysis by synthesis coding
    Zigel, Y
    Cohen, A
    Katz, A
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (10) : 1308 - 1316
  • [39] ECG Signal Compression Using Adaptive Hermite Functions
    Dozsa, Tamas
    Kovacs, Peter
    ICT INNOVATIONS 2015: EMERGING TECHNOLOGIES FOR BETTER LIVING, 2016, 399 : 245 - 254
  • [40] Vector quantization neural network for ECG signal compression
    Bhatt, NS
    Shah, SK
    2002 IEEE REGION 10 CONFERENCE ON COMPUTERS, COMMUNICATIONS, CONTROL AND POWER ENGINEERING, VOLS I-III, PROCEEDINGS, 2002, : 625 - 628