An efficient Fourier method for 3-D radon inversion in exact cone-beam CT reconstruction

被引:31
|
作者
Schaller, S
Flohr, T
Steffen, P
机构
[1] Siemens AG, Med GT4, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Telecommun, D-91058 Erlangen, Germany
关键词
cone-beam computed tomography; Fourier reconstruction; gridding; radon transform;
D O I
10.1109/42.700736
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The radial derivative of the three-dimensional (3-D) radon transform of an object is an important intermediate result in many analytically exact cone-beam reconstruction algorithms. We briefly review Grangeat's approach for calculating radon derivative data from cone-beam projections and then present a new, efficient method for 3-D radon inversion, i.e., reconstruction of the image from the radial derivative of the 3-D radon transform, called direct Fourier inversion (DFI), The method is based directly on the 3-D Fourier slice theorem. From the 3-D radon derivative data, which is assumed to be sampled on a spherical grid, the 3-D Fourier transform of the object is calculated by performing fast Fourier transforms (FFT's) along radial lines in the radon space. Then, an interpolation is performed from the spherical to a Cartesian grid using a 3-D gridding step in the frequency domain. Finally, this 3-D Fourier transform is transformed back to the spatial domain via 3-D inverse FFT, The algorithm is computationally efficient with complexity in the order of N-3 log N. We have done reconstructions of simulated 3-D radon derivative data assuming sampling conditions and image quality requirements similar to those in medical computed tomography (CT).
引用
下载
收藏
页码:244 / 250
页数:7
相关论文
共 50 条
  • [11] The radon-split method for helical cone-beam CT and its application to nongated reconstruction
    Koehler, Thomas
    Bontus, Claas
    Koken, Peter
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 882 - 897
  • [12] Exact reconstruction of volumetric images in reverse helical cone-beam CT
    Cho, Seungryong
    Xia, Dan
    Pelizzari, Charles A.
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2008, 35 (07) : 3030 - 3040
  • [13] Motion artefact reduction for exact cone-beam CT reconstruction algorithms
    Koken, P
    Köhler, T
    Bontus, C
    Proksa, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2985 - 2988
  • [14] Exact image reconstruction for selected ROI in helical cone-beam CT
    Pan, XC
    Zou, Y
    Xia, D
    Sidky, E
    Jiang, TZ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3773 - 3776
  • [15] A parallel backprojection algorithm for spiral cone-beam ct exact reconstruction
    Xue G.
    Zhang Y.
    International Journal of Digital Content Technology and its Applications, 2010, 4 (06) : 134 - 143
  • [16] Physical phantom studies of helical cone-beam CT with exact reconstruction
    Tan, Jun
    Li, H. Harold
    Klein, Eric
    Li, Hua
    Parikh, Parag
    Yang, Deshan
    MEDICAL PHYSICS, 2012, 39 (08) : 4695 - 4704
  • [17] An efficient linogram sampling method for cone-beam reconstruction
    Kudo, H
    Saito, T
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1165 - 1169
  • [18] 3-D reconstruction of an axisymmetric flame based on cone-beam tomographic algorithms
    He, Yuting
    Lu, Gang
    Yan, Yong
    2016 10TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2016,
  • [19] Exact radon rebinning algorithm for the long object problem in helical cone-beam CT
    Schaller, S
    Noo, F
    Sauer, F
    Tam, KC
    Lauritsch, G
    Flohr, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 361 - 375
  • [20] 3D Analytic Cone-Beam Reconstruction for Multiaxial CT Acquisitions
    Yin, Zhye
    De Man, Bruno
    Pack, Jed
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2009, 2009