Monoenergetic extrapolation of cardiac dual energy CT for artifact reduction

被引:59
|
作者
Secchi, Francesco [1 ,2 ]
De Cecco, Carlo Nicola [1 ,3 ]
Spearman, James Vance [1 ]
Silverman, Justin Robert [1 ]
Ebersberger, Ullrich [1 ,4 ]
Sardanelli, Francesco [2 ,5 ]
Schoepf, U. Joseph [1 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[2] IRCCS, Policlin San Donato, Radiol Unit, San Donato Milanese, Italy
[3] Univ Roma La Sapienza, Dept Radiol Sci Oncol & Pathol, Latina, Italy
[4] Heart Ctr Munich Bogenhausen, Dept Cardiol & Intens Care Med, Munich, Germany
[5] Univ Milan, Dipartimento Sci Biomed Salute, Milan, Italy
关键词
Dual energy CT (DECT); artifact; monoenergetic extrapolation; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; ABDOMEN; HEART;
D O I
10.1177/0284185114527867
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Monoenergetic extrapolation of cardiac dual-energy computed tomography (DECT) could be useful in artifact reduction in clinical practice. Purpose: To evaluate the potential of monoenergetic extrapolation of cardiac DECT data for reducing artifacts from metal and high iodine contrast concentration. Material and Methods: With IRB approval and in HIPAA compliance, 35 patients (22 men, 61 +/- 12 years) underwent cardiac DECT with dual-source CT (100 kVp and 140 kVp). Contrast material injection protocols were adapted to the patient's weight using non-ionic low-osmolar 370 mgI/mL iopromide. Datasets were transferred to a stand-alone workstation and dedicated monoenergetic analysis software was used for postprocessing. Reconstructions with the following five photon energies were generated: 40 keV, 60 keV, 80 keV, 100 keV, and 120 keV. Artifact severity was graded on a 5-point Likert scale (0, massive artifact; 5, absence of artifact). The size of artifact and image noise (expressed as HU) in anatomic structures adjacent to the artifact were measured. Quantitative and subjective image quality was compared using Friedman and Wilcoxon tests. Results: We observed artifacts arising from densely concentrated contrast material in the superior vena cava (SVC) in 18 patients, from sternal wires in 14, from bypass clips in eight, and from coronary artery stents in seven. Artifact size in monoenergetic reconstructions from 40 to 120 keV decreased from 21.3 to 19mm for the SVC (P < 0.001), from 8.4 to 2.6mm for sternal wires (P < 0.001), from 6.4 to 2.2mm for bypass clips (P < 0.001), and from 5.9 to 2.7mm for stents (P < 0.001), respectively. The quality score changed from 0.2 to 3.8 for the SVC (P < 0.001), from 0.1 to 4 for sternal wires (P < 0.001), from 0 to 3.9 for bypass clips (P < 0.001), and from 0 to 3.9 for stents (P < 0.001). Lowest noise in adjacent structures was found at 80 keV for the SVC (39.1 HU), for sternal wires (33.3), for bypass clips (26.9), and for stents (33.9). Conclusion: A significant reduction of high-attenuation artifacts can be achieved by use of higher monoenergetic energy levels with cardiac DECT. However, image noise in anatomic structures affected by artifacts is lowest at 80 keV, which suggests an evaluation approach that makes use of multiple energy levels for a complete diagnosis.
引用
收藏
页码:413 / 418
页数:6
相关论文
共 50 条
  • [1] Metal artifact reduction by monoenergetic extrapolation of dual-energy CT in patients with metallic implants
    Lee, Ka Yin Gregory
    Cheng, Hei Man Joyce
    Chu, Chi Yeung
    Tam, Chi Wai Annie
    Kan, Wai Kuen
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [2] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Fabian Bamberg
    Alexander Dierks
    Konstantin Nikolaou
    Maximilian F. Reiser
    Christoph R. Becker
    Thorsten R. C. Johnson
    European Radiology, 2011, 21 : 1424 - 1429
  • [3] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Bamberg, Fabian
    Dierks, Alexander
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    EUROPEAN RADIOLOGY, 2011, 21 (07) : 1424 - 1429
  • [4] The application of metal artifact reduction (MAR) in CT scans for radiation oncology by monoenergetic extrapolation with a DECT scanner
    Schwahofer, Andrea
    Baer, Esther
    Kuchenbecker, Stefan
    Grossmann, J. Guenter
    Kachelriess, Marc
    Sterzing, Florian
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2015, 25 (04): : 314 - 325
  • [5] Optimization of Monoenergetic Extrapolations in Dual-Energy CT for Metal Artifact Reduction in Different Body Regions and Orthopedic Implants
    Horat, Lukas
    Hamie, Mustafa Q.
    Huber, Florian A.
    Guggenberger, Roman
    ACADEMIC RADIOLOGY, 2019, 26 (05) : E67 - E74
  • [6] Evaluation of metal artefacts reduction by application of monoenergetic extrapolation of dual-energy CT: A phantom study with different metal implants
    Saidun, H. A.
    Shuaib, I. L.
    Daud, N. M.
    Sobri, N. F. M.
    Osman, N. D.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [7] Metal Artifact Reduction in Virtual Monoenergetic Spectral Dual-Energy CT of Patients With Metallic Orthopedic Implants in the Distal Radius
    Yoo, Hye Jin
    Hong, Sung Hwan
    Chung, Bo Mi
    Moon, Sun Jeong
    Choi, Ja-Young
    Chae, Hee Dong
    Chang, Min-Yung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (05) : 1083 - 1091
  • [8] Single energy metal artifact reduction performs better than virtual monoenergetic dual-energy reconstruction in CT of the equine proximal phalanx
    Faulkner, Josephine E.
    Broeckx, Bart J. G.
    Martens, Ann
    Raes, Els
    Haardt, Hanna
    Vanderperren, Katrien
    VETERINARY RADIOLOGY & ULTRASOUND, 2023, 64 (04) : 677 - 685
  • [9] Combination of Iterative Metal Artifact Reduction and Virtual Monoenergetic Reconstruction Using Split-Filter Dual-Energy CT in Patients With Dental Artifact on Head and Neck CT
    Schmidt, Alexander Marcel Alfred
    Grunz, Jan-Peter
    Petritsch, Bernhard
    Gruschwitz, Philipp
    Knarr, Jonas
    Huflage, Henner
    Bley, Thorsten Alexander
    Kosmala, Aleksander
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (04) : 716 - 727
  • [10] Metal Artifact Reduction Algorithm for Single Energy and Dual Energy CT Scans
    Chang, Yu-Bing
    Xu, Dan
    Zamyatin, Alexander A.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3426 - 3429