Development of a biological ventricular assist device -: Preliminary data from a small animal model

被引:64
|
作者
Yildirim, Yalin
Naito, Hiroshi
Didie, Michael
Karikkineth, Bijoy Chandapillai
Biermann, Daniel
Eschenhagen, Thomas
Zimmermann, Wolfram-Hubertus
机构
[1] Univ Hamburg, Inst Expt, D-20246 Hamburg, Germany
[2] Univ Hamburg, Clin Pharmacol & Toxicol, D-20246 Hamburg, Germany
关键词
tissue engineering; myocardium; cardiomyocyte; regeneration; transplantation;
D O I
10.1161/CIRCULATIONAHA.106.679688
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Engineered heart tissue (EHT) can be generated from cardiomyocytes and extracellular matrix proteins and used to repair local heart muscle defects in vivo. Here, we hypothesized that pouch-like heart muscle constructs can be generated by using a novel EHT-casting technology and applied as heart-embracing cardiac grafts in vivo. Methods and Results - Pouch-like EHTs (inner/outer diameter: 10/12 mm) can be generated mainly from neonatal rat heart cells, collagen type I, and serum containing culture medium. They contain a dense network of connexin 43 interconnected cardiomyocytes and an endo-/epicardial surface lining composed of prolylhydroxylase positive cells. Pouch-like EHTs beat spontaneously and show contractile properties of native heart muscle including positive inotropic responses to calcium and isoprenaline. First implantation studies indicate that pouch-like EHTs can be slipped over uninjured adult rat hearts to completely cover the left and right ventricles. Fourteen days after implantation, EHT-grafts stably covered the epicardial surface of the respective hearts. Engrafted EHTs were composed of matrix and differentiated cardiac muscle as well as newly formed vessels which were partly donor-derived. Conclusions - Pouch-like EHTs can be generated with structural and functional properties of native myocardium. Implantation studies demonstrated their applicability as cardiac muscle grafts, setting the stage for an evaluation of EHT-pouches as biological ventricular assist devices in vivo.
引用
收藏
页码:I16 / I23
页数:8
相关论文
共 50 条
  • [41] The effect of left ventricular function and drive pressures on the filling and ejection of a pulsatile pediatric ventricular assist device in an acute animal model
    Lukic, Branka
    Zapanta, Conrad M.
    Khalapyan, Tigran
    Connell, John
    Pae, Walter E.
    Myers, John L.
    Wilson, Ronald P.
    Undar, Akif
    Rosenberg, Gerson
    Weiss, William J.
    ASAIO JOURNAL, 2007, 53 (03) : 379 - 384
  • [42] Development of a direct mechanical left ventricular assist device for left ventricular failure
    Hotei, H
    Koura, Y
    Orihashi, K
    Sueda, T
    Fukunaga, S
    Matsuura, Y
    ARTIFICIAL ORGANS, 1997, 21 (09) : 1026 - 1034
  • [43] Development of a direct mechanical left ventricular assist device for left ventricular failure
    Hotei, Hiroshi
    Koura, Yoshihiko
    Orihashi, Kazumasa
    Sueda, Taijiro
    Fukunaga, Sintaro
    Matsuura, Yuichiro
    1997, (21)
  • [44] Small Left Ventricular Size Is an Independent Risk Factor for Ventricular Assist Device Thrombosis
    Chivukula, Venkat Keshav
    Beckman, Jennifer A.
    Prisco, Anthony R.
    Lin, Shin
    Dardas, Todd F.
    Cheng, Richard K.
    Farris, Stephen D.
    Smith, Jason W.
    Mokadam, Nahush A.
    Mahr, Claudius
    Aliseda, Alberto
    ASAIO JOURNAL, 2019, 65 (02) : 152 - 159
  • [45] Animal survival experiments for ventricular assist device of "TongXin Demo4"
    Xu, Chuangye
    Lin, Changyan
    Liu, Xiujian
    Wu, Guanghui
    Hou, Xiaotong
    Li, Haiyang
    Yang, Peng
    CARDIOLOGY, 2013, 126 : 66 - 67
  • [46] A novel implantable electromechanical ventricular assist device - First acute animal testing
    Kaufmann, R
    Rakhorst, G
    Mihaylov, D
    Elstrodt, J
    Nix, C
    Reul, H
    Rau, G
    ASAIO JOURNAL, 1997, 43 (04) : 360 - 362
  • [47] Development of a ventricular assist device for out-of-hospital use
    Mussivand, T
    Hendry, PJ
    Masters, RG
    Keon, WJ
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1999, 18 (02): : 166 - 171
  • [48] Development of the DexAide right ventricular assist device inflow cannula
    Ootaki, Yoshio
    Saeed, Diyar
    Ootaki, Chiyo
    Akiyama, Masatoshi
    Fumoto, Hideyuki
    Horai, Tetsuya
    Dessoffy, Raymond
    Catanese, Jacquelyn
    Massiello, Alex
    Horvath, David
    Chen, Ji-Feng
    Benefit, Stephen
    Golding, Leonard A. R.
    Fukamachi, Kiyotaka
    ASAIO JOURNAL, 2008, 54 (01) : 31 - 36
  • [49] Development and Preclinical Testing of a Miniaturized Implantable Ventricular Assist Device
    Arndt, A.
    Graichen, K.
    Mueller, J.
    Erd, L.
    Krambeck, H.
    Goellner, M.
    Nuesser, P.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 26 - 26
  • [50] Development of a prototype magnetically suspended rotor ventricular assist device
    Bearnson, GB
    Maslen, EH
    Olsen, DB
    Allaire, PE
    Khanwilkar, PS
    Long, JW
    Kim, HC
    ASAIO JOURNAL, 1996, 42 (04) : 275 - 281