First X-ray test of the Icarus nanosecond-gated camera

被引:14
|
作者
Hart, Philip A. [1 ]
Carpenter, Andrew [2 ]
Claus, Liam [3 ]
Damiani, Daniel [1 ]
Dayton, Matthew [2 ]
Decker, Franz-Josef [1 ]
Gleason, Arianna [1 ]
Heimann, Philip [1 ]
Hurd, Emily [2 ]
McBride, Emma [1 ]
Nelson, Silke [1 ]
Sanchez, Marcos [3 ]
Song, Sanghoon [1 ]
Zhu, Diwen [1 ]
机构
[1] SLAC Natl Accelerator Lab, LCLS, Stanford, CA 94025 USA
[2] NIF, Lawrance Livermore Natl Lab, Livermore, CA USA
[3] Sandia Natl Labs, POB 5800, Albuquerque, NM 87185 USA
关键词
UXI; LCLS; Icarus; X-ray imager; FEL detectors; XPCS; shock; plasma;
D O I
10.1117/12.2520974
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Icarus camera system, combining a sensor developed by Sandia and readout electronics by LLNL, provides 0.5 Hz bursts of four frames with 3 ns separation. The sensor has 1024x512 25 mu m pixels and is 25 mu m thick. The system was developed for single line-of-sight measurements at the ns time scale for electrons and X-rays at facilities such as NIF. We report on initial tests of the Icarus system with hard X-rays pulse pairs with nanosecond time spacings at the LCLS, a newly available beam mode. We describe noise, gate profiles, gain, cross-talk, persistence, linearity, and quantum efficiency for the first version of the sensor. We present evidence of the suitability of the system for science measurements at a free electron laser with an X-ray pump X-ray probe experiment. We expect further developments of the technology to allow use of 350 ps bunch separation from the LCLS accelerator and, with a pulsed delay tube like DIXIE, to eventually reach sub-25 ps time-resolved X-ray imaging of processes such as plasma evolution.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [21] X-RAY TOPOGRAPHIC CAMERA
    CARRON, GJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (05): : 628 - &
  • [22] Spatially resolved research of picosecond X-ray multiframes camera with gated microchannel plate
    State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China
    不详
    不详
    Guangzi Xuebao, 2007, 12 (2209-2214):
  • [23] Gated X-ray framing camera image of a direct-drive cylindrical implosion
    Voss, SA
    Barnes, CW
    Oertel, JA
    Watt, RG
    Boehly, TR
    Bradley, DK
    Knauer, JP
    Pien, G
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1999, 27 (01) : 132 - 133
  • [24] Gated X-ray framing camera image of a direct-drive cylindrical implosion
    Los Alamos National Laboratory, Los Alamos, NM 87545, United States
    不详
    IEEE Trans Plasma Sci, 1 (132-133):
  • [25] The cooling test platform design for iter radial x-ray camera
    Zhang, Bin
    Zhang, Sheng
    Chen, Yebin
    Hu, Liqun
    Li, Shi
    Wu, Keping
    Zhu, Zhigang
    Zhao, Jinlong
    FUSION ENGINEERING AND DESIGN, 2018, 128 : 163 - 167
  • [26] First Demonstration of Compton Camera Used for X-Ray Fluorescence Imaging
    Wu, Chuanpeng
    Li, Liang
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (05) : 1314 - 1324
  • [27] Vacuum Design of An X-Ray Camera Using Triboelectric X-Ray
    Moya-Sanchez, Spectra E. Ulises
    Romo-Espejel, J. A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [28] Research on coupling of an X-ray mirror to an X-ray framing camera
    Miao, Wen-Yong
    Chen, Jin-Xiu
    Hu, Xin
    Wang, Yao-Mei
    Cao, Zhu-Rong
    Dong, Jian-Jun
    Chen, Ming
    Tang, Chang-Huan
    Guangzi Xuebao/Acta Photonica Sinica, 2007, 36 (04): : 750 - 753
  • [29] A hybrid X-ray camera for the next generation X-ray satellite
    Tsuru, TG
    Bamba, A
    Imanishi, K
    Kohno, M
    Koyama, K
    Murakami, H
    Tsujimoto, M
    Tanimori, T
    Ueno, M
    NEW CENTURY OF X-RAY ASTRONOMY, 2001, 251 : 596 - 597
  • [30] X-ray focusing test and x-ray imaging test by a microcapillary x-ray lens at an undulator beamline
    Kohmura, Y
    Awaji, M
    Suzuki, Y
    Ishikawa, T
    Dudchik, YI
    Kolchevsky, NN
    Komarov, FF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (11): : 4161 - 4167