Compressive performance of RAC filled GFRP tube-profile steel composite columns under axial loads

被引:2
|
作者
Ma, Hui [1 ,2 ]
Bai, Hengyu [1 ]
Zhao, Yanli [3 ]
Liu, Yunhe [1 ,2 ]
Zhang, Peng [1 ]
机构
[1] Xian Univ Technol, Sch Civil Engn & Architecture, Xian 710048, Peoples R China
[2] Xian Univ Technol, State Key Lab Ecohydraul Northwest Arid Reg, Xian 710048, Peoples R China
[3] Changan Univ, Sch Architecture, Xian 710064, Peoples R China
基金
中国国家自然科学基金;
关键词
recycled aggregate concrete; GFRP tube; profiles steel; composite column; axial compression behavior; RECYCLED AGGREGATE CONCRETE; FRP-CONFINED CONCRETE; STRESS-STRAIN MODEL; BEHAVIOR; CONSTRUCTION; DURABILITY;
D O I
10.12989/acc.2019.8.4.335
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To investigate the axial compressive performance of the recycled aggregate concrete (RAC) filled glass fiber reinforced polymer (GFRP) tube and profile steel composite columns, static loading tests were carried out on 18 specimens under axial loads in this study, including 7 RAC filled GFRP tube columns and 11 RAC filled GFRP tube-profile steel composite columns. The design parameters include recycled coarse aggregate (RCA) replacement percentage, profile steel ratio, slenderness ratio and RAC strength. The failure process, failure modes, axial stress-strain curves, strain development and axial bearing capacity of all specimens were mainly analyzed in detail. The experimental results show that the GFRP tube had strong restraint ability to RAC material and the profile steel could improve the axial compressive performance of the columns. The failure modes of the columns can be summarized as follow: the profile steel in the composite columns yielded first, then the internal RAC material was crushed, and finally the fiberglass of the external GFRP tube was seriously torn, resulting in the final failure of columns. The axial bearing capacity of the columns decreased with the increase of RCA replacement percentage and the maximum decreasing amplitude was 11.10%. In addition, the slenderness ratio had an adverse effect on the axial bearing capacity of the columns. However, the strength of the RAC material could effectively improve the axial bearing capacity of the columns, but their deformability decreased. In addition, the increasing profile steel ratio contributed to the axial compressive capacity of the composite columns. Based on the above analysis, a formula for calculating the bearing capacity of composite columns under axial compression load is proposed, and the adverse effects of slenderness ratio and RCA replacement percentage are considered.
引用
收藏
页码:335 / 349
页数:15
相关论文
共 50 条
  • [41] Structural behavior of UHPC filled steel tube columns under axial loading
    Chen, Shiming
    Zhang, Rui
    Jia, Liang-Jiu
    Wang, Jun-Yan
    Gu, Ping
    THIN-WALLED STRUCTURES, 2018, 130 : 550 - 563
  • [42] Axial compressive behaviour of ultra-high performance concrete filled steel tube stub columns at elevated temperatures
    Xue, Congcong
    Yu, Min
    Wu, Mingyang
    Cheng, Shanshan
    STRUCTURES, 2023, 57
  • [43] Axial Compressive Behavior of CFRP-UHPC-Steel Tube Composite Short Columns
    Deng Z.
    Li W.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2021, 54 (10): : 1008 - 1016
  • [44] Strengthening of deficient steel SHS columns under axial compressive loads using CFRP
    Shahraki, Mehdi
    Sohrabi, Mohammad Reza
    Azizyan, Gholamreza
    Narmashiri, Kambiz
    STEEL AND COMPOSITE STRUCTURES, 2019, 30 (01): : 69 - 79
  • [45] Strengthening of corroded steel CHS columns under axial compressive loads using CFRP
    Youse, Omid
    Narmashiri, Kambiz
    Hedayat, Amir Ahmad
    Karbakhsh, Ali
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 178
  • [46] Performance of circular concrete-filled fiber-reinforced polymer-steel composite tube columns under axial compression
    Wei, Yang
    Wu, Gang
    Li, Guofen
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2014, 33 (20) : 1911 - 1928
  • [47] Axial compressive behavior of steel fiber reinforced concrete-filled square steel tube stub columns
    Liu, Zhenzhen
    Huang, Dongming
    Wu, Haozhou
    Lu, Yiyan
    Luo, Xi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 203
  • [48] Experimental and computational study of concrete filled steel tubular columns under axial loads
    Gupta, P. K.
    Sarda, S. M.
    Kumar, M. S.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (02) : 182 - 193
  • [49] Research on eccentric compressive behavior of steel fiber reinforced recycled concrete-filled GFRP tube columns
    Huang, Dongming
    Liu, Zhenzhen
    Liu, Peng
    Lu, Yiyan
    Li, Shan
    COMPOSITE STRUCTURES, 2022, 301
  • [50] Axial Compressive Behavior and Bearing Capacity Calculation of Marine Concrete Filled Stainless Steel Tube Columns with Built-in Carbon Steel Under Axial Compression
    Chen, Zongping
    Li, Jiancheng
    Zhou, Ji
    Cailiao Daobao/Materials Reports, 2024, 38 (12):