Pneumatic lower extremity compression during dobutamine stress echocardiography

被引:4
|
作者
Sohn, Dae-Won [1 ]
Kim, Hyung-Kwan [1 ]
Park, Jin-Shik [1 ]
Kim, Yong-Jin [1 ]
Zo, Joo-Hee [1 ]
Oh, Byung-Hee [1 ]
Park, Young-Bae [1 ]
Choi, Yun-Shik [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Internal Med, Div Cardiol, Seoul 110744, South Korea
关键词
diagnostic accuracy; dobutamine stress echocardiography; pneumatic compression;
D O I
10.1253/circj.72.251
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Afterload is expected to increase with pneumatic compression of the lower extremities. There are left ventricular (LV) wall stress, which is the most important factor determining myocardial oxygen demand, will also increase, leading to an increase in the sensitivity of dobutamine stress echocardiography (DSE) or a shortened time to a positive response. Methods and Results In 40 patients who underwent DSE and were anticipating undergoing coronary angiography (CAG), the imaging was repeated with pneumatic compression (100mmHg) of the lower extremities (DSEcomp) prior to CAG. The sensitivity and specificity of DSE and DSEcomp were determined based on the CAG findings. All patients tolerated pneumatic compression of the lower extremities during the tests. LV end-systolic volume (p=0.042) and end-systolic wall stress (p=0.036) were significantly greater with DSEcomp than with DSE. In 3 patients with false-negative results for DSE, DSEcomp gave a positive response, demonstrating a significant increase in sensitivity from 75% to 94% (p=0.045). Only 1 patient with a true negative result for DSE was interpreted as showing a positive response for DSEcomp, resulting in a decrease in specificity from 88% to 83% (p=NS). In 10 of 12 patients with true positive results for both DSE and DSEcomp, positive responses were seen at least 1 stage earlier with DSEcomp than with DSE. Conclusions Pneumatic compression of the lower extremities increases the sensitivity of DSE and shortens the time to a positive response.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 50 条
  • [31] Pneumatic Compression Improves Quality of Life in Patients with Lower-Extremity Lymphedema
    Blumberg, Sheila N.
    Berland, Todd
    Rockman, Caron
    Mussa, Firas
    Brooks, Allison
    Cayne, Neal
    Maldonado, Thomas
    ANNALS OF VASCULAR SURGERY, 2016, 30 : 40 - 44
  • [32] Intermittent pneumatic compression for the treatment of lower extremity arterial disease: a systematic review
    Labropoulos, N
    Wierks, C
    Suffoletto, B
    VASCULAR MEDICINE, 2002, 7 (02) : 141 - 148
  • [33] Hemodynamics of the lower extremity with pneumatic foot compression.: The effect of the position of the limb
    Pitto, RP
    Hamer, H
    Kühle, JW
    Radespiel-Tröoger, M
    Pietsch, M
    BIOMEDIZINISCHE TECHNIK, 2001, 46 (05): : 124 - 128
  • [34] The efficacy of intermittent pneumatic compression in the prevention of lower extremity deep venous thrombosis
    Sadaghianloo, Nirvana
    Dardik, Alan
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2016, 4 (02) : 248 - 256
  • [35] Prognostic value of the dose of dobutamine needed to induce ischemia during dobutamine stress echocardiography
    Xie, TR
    Khan, M
    Garza, J
    Adams, M
    EsquivelAvila, JG
    Ahmad, M
    CIRCULATION, 1997, 96 (08) : 1534 - 1534
  • [36] Dobutamine stress-echocardiography
    Sedov, VP
    Alekhin, MN
    Bozhiev, AM
    KARDIOLOGIYA, 1997, 37 (07) : 96 - 103
  • [37] Dobutamine stress echocardiography - Reply
    Pearson, AC
    Orsinelli, DA
    Latcham, AP
    AMERICAN HEART JOURNAL, 1996, 131 (06) : 1233 - 1233
  • [38] Dobutamine, dipyridamole, and stress echocardiography
    Bernardino, L
    CIRCULATION, 1996, 94 (11) : 2989 - 2989
  • [39] HYPOTENSION AND DOBUTAMINE STRESS ECHOCARDIOGRAPHY
    PONTILLO, D
    CAPEZZUTO, A
    ACHILLI, A
    CIRCULATION, 1994, 89 (05) : 2459 - 2459
  • [40] β-Adrenergic receptor gene polymorphisms and hemodynamic response to dobutamine during dobutamine stress echocardiography
    Aquilante, C. L.
    Yarandi, H. N.
    Cavallari, L. H.
    Andrisin, T. E.
    Terra, S. G.
    Lewis, J. F.
    Hamilton, K. H.
    Johnson, J. A.
    PHARMACOGENOMICS JOURNAL, 2008, 8 (06): : 408 - 415