A New Stray-Load Loss Formula for Small and Medium-Sized Induction Motors

被引:41
|
作者
Pillay, Pragasen [1 ,2 ]
Al-Badri, Maher [1 ]
Angers, Pierre [3 ]
Desai, Chirag [1 ]
机构
[1] Concordia Univ, Dept Elect & Comp Engn, Montreal, PQ H3G 1M8, Canada
[2] Univ Cape Town, ZA-7701 Rondebosch, South Africa
[3] Inst Rech Hydro Quebec, Lab Technol Energie, Shawinigan, PQ G9N 7N5, Canada
关键词
BC Hydro; copper loss; core loss; efficiency; friction and windage losses; hydro-Quebec; IEC; 60034-2-1; IEEE Std 112-B; induction motor; stray-load loss; STANDARDS; VOLTAGE;
D O I
10.1109/TEC.2016.2539959
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a new stray-load loss (SLL) formula for small and medium induction motors (IMs) based on tests data of a 182, 60 Hz IMs in the range of 1-500 hp (0.75-375 kW). They are all tested in accordance with IEEE Std 112-Method B. The proposed formula is validated by recalculating the efficiency of the same number of motors by using the proposed formula, as well as the IEEE Std 112 and the IEC 60034-2-1 standards. Another validation was done on testing 17 additional IMs that are independent of the 182-motor data. In both validations, the new formula demonstrates better accuracy. This formula shows the potential to replace the existing SLL estimation formula for this horsepower range.
引用
收藏
页码:1221 / 1227
页数:7
相关论文
共 50 条
  • [31] Entrepreneurship in small and medium-sized towns
    Mayer, Heike
    Motoyama, Yasuyuki
    ENTREPRENEURSHIP AND REGIONAL DEVELOPMENT, 2020, 32 (7-8): : 467 - 472
  • [32] The Internationalization of Small and Medium-Sized Firms
    Dirk De Clercq
    Harry J. Sapienza
    Hans Crijns
    Small Business Economics, 2005, 24 : 409 - 419
  • [33] Evaluation of stray load loss in induction motors with a comparison of input-output and calorimetric methods
    Bradley, Keith J.
    Cao, Wenping
    Arellano-Padilla, Jesus
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (03) : 682 - 689
  • [34] Role of small and medium-sized reactors
    Kupitz, J.
    Mourogov, V.
    Nuclear Energy, 1999, 38 (04): : 239 - 247
  • [35] The role of small and medium-sized reactors
    Kupitz, J
    Mourogov, V
    NUCLEAR ENERGY-JOURNAL OF THE BRITISH NUCLEAR ENERGY SOCIETY, 1999, 38 (04): : 239 - 247
  • [36] Electric load shape benchmarking for small- and medium-sized commercial buildings
    Luo, Xuan
    Hong, Tianzhen
    Chen, Yixing
    Piette, Mary Ann
    APPLIED ENERGY, 2017, 204 : 715 - 725
  • [37] Stray load loss analysis of induction motors due to harmonic electromagnetic fields of stator and rotor
    Yamazaki, K
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2005, 15 (03): : 299 - 310
  • [38] Evaluation of stray load loss in induction motors, A comparison of input-output and calorimetric methods
    Bradley, KJ
    Cao, WP
    CONFERENCE RECORD OF THE 2001 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2001, : 754 - 761