Design and testing of a low-cost sensor and sampling platform for indoor air quality

被引:37
|
作者
Tryner, Jessica [1 ,2 ]
Phillips, Mollie [2 ]
Quinn, Casey [3 ]
Neymark, Gabe [2 ]
Wilson, Ander [4 ]
Jathar, Shantanu H. [1 ]
Carter, Ellison [5 ]
Volckens, John [1 ]
机构
[1] Colorado State Univ, Dept Mech Engn, 1374 Campus Delivery, Ft Collins, CO 80523 USA
[2] Access Sensor Technol, 320 East Vine Dr,Suite 221, Ft Collins, CO 80524 USA
[3] NSG Engn Solut, 227 Cent St NE, Olympia, WA 98506 USA
[4] Colorado State Univ, Dept Stat, 1801 Campus Delivery, Ft Collins, CO 80523 USA
[5] Colorado State Univ, Dept Civil & Environm Engn, 1372 Campus Delivery, Ft Collins, CO 80523 USA
基金
美国国家卫生研究院;
关键词
Electrochemical gas sensors; Gas cooking burners; Particulate matter; Nitrogen dioxide; NO2; Wildfire smoke; GAS COOKING BURNERS; ELECTROCHEMICAL SENSORS; CALIBRATION MODEL; PERSONAL EXPOSURE; PERFORMANCE; PM2.5;
D O I
10.1016/j.buildenv.2021.108398
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Americans spend most of their time indoors at home, but comprehensive characterization of in-home air pollution is limited by the cost and size of reference-quality monitors. We assembled small "Home Health Boxes" (HHBs) to measure indoor PM2.5, PM10, CO2, CO, NO2, and O-3 concentrations using filter samplers and low-cost sensors. Nine HHBs were collocated with reference monitors in the kitchen of an occupied home in Fort Collins, Colorado, USA for 168 h while wildfire smoke impacted local air quality. When HHB data were interpreted using gas sensor manufacturers' calibrations, HHBs and reference monitors (a) categorized the level of each gaseous pollutant similarly (as either low, elevated, or high relative to air quality standards) and (b) both indicated that gas cooking burners were the dominant source of CO and NO2 pollution; however, HHB and reference O-3 data were not correlated. When HHB gas sensor data were interpreted using linear mixed calibration models derived via collocation with reference monitors, root-mean-square error decreased for CO2 (from 408 to 58 ppm), CO (645 to 572 ppb), NO2 (22 to 14 ppb), and O-3 (21 to 7 ppb); additionally, correlation between HHB and reference O-3 data improved (Pearson's r increased from 0.02 to 0.75). Mean 168-h PM2.5 and PM10 concentrations derived from nine filter samples were 19.4 mu g m(-3) (6.1% relative standard deviation [RSD]) and 40.1 mu g m(-3) (7.6% RSD). The 168-h PM2.5 concentration was overestimated by PMS5003 sensors (median sensor/filter ratio = 1.7) and underestimated slightly by SPS30 sensors (median sensor/filter ratio = 0.91).
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [41] Low-Cost Sensor Network for Air Quality Assessment in Cabo Verde Islands
    da Costa, Anedito Zico
    Aniceto, José P. S.
    Lopes, Myriam
    Sensors, 2024, 24 (23)
  • [42] Analysis and Improvement of Two Low-Cost Air Quality Sensor Measurements' Uncertainty
    Panourgias, Marios
    Karatzas, Kostas
    ADVANCES AND NEW TRENDS IN ENVIRONMENTAL INFORMATICS, 2023, : 73 - 89
  • [43] Deployment and Evaluation of a Network of Open Low-Cost Air Quality Sensor Systems
    Schneider, Philipp
    Vogt, Matthias
    Haugen, Rolf
    Hassani, Amirhossein
    Castell, Nuria
    Dauge, Franck R.
    Bartonova, Alena
    ATMOSPHERE, 2023, 14 (03)
  • [44] Application of low-cost sensor system to measure air quality on the university campus
    Tatarczak, Jaroslaw
    PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (12): : 241 - 245
  • [45] Low-cost stabilized platform for airborne sensor positioning
    Gonzalez-Castano, F. J.
    Gil-Castineira, F.
    Pousada-Carballo, J. M.
    Rodriguez-Hernandez, P. S.
    Burguillo-Rial, J. C.
    Dosil-Outes, I.
    KNOWLEDGE-BASED INTELLIGENT INFORMATION AND ENGINEERING SYSTEMS, PT 3, PROCEEDINGS, 2006, 4253 : 263 - 268
  • [46] Sensor "Bottleneck" and a Design of Low-Cost Pressure Sensor
    Wu, Zeqiu
    2010 INTERNATIONAL CONFERENCE ON INFORMATION, ELECTRONIC AND COMPUTER SCIENCE, VOLS 1-3, 2010, : 936 - 939
  • [47] Development of a low-cost sensing platform for air quality monitoring: application in the city of Rome
    Shindler, Luca
    Environmental Technology (United Kingdom), 2021, 42 (04): : 618 - 631
  • [48] Development of a low-cost sensing platform for air quality monitoring: application in the city of Rome
    Shindler, Luca
    ENVIRONMENTAL TECHNOLOGY, 2021, 42 (04) : 618 - 631