Design and testing of a low-cost sensor and sampling platform for indoor air quality

被引:37
|
作者
Tryner, Jessica [1 ,2 ]
Phillips, Mollie [2 ]
Quinn, Casey [3 ]
Neymark, Gabe [2 ]
Wilson, Ander [4 ]
Jathar, Shantanu H. [1 ]
Carter, Ellison [5 ]
Volckens, John [1 ]
机构
[1] Colorado State Univ, Dept Mech Engn, 1374 Campus Delivery, Ft Collins, CO 80523 USA
[2] Access Sensor Technol, 320 East Vine Dr,Suite 221, Ft Collins, CO 80524 USA
[3] NSG Engn Solut, 227 Cent St NE, Olympia, WA 98506 USA
[4] Colorado State Univ, Dept Stat, 1801 Campus Delivery, Ft Collins, CO 80523 USA
[5] Colorado State Univ, Dept Civil & Environm Engn, 1372 Campus Delivery, Ft Collins, CO 80523 USA
基金
美国国家卫生研究院;
关键词
Electrochemical gas sensors; Gas cooking burners; Particulate matter; Nitrogen dioxide; NO2; Wildfire smoke; GAS COOKING BURNERS; ELECTROCHEMICAL SENSORS; CALIBRATION MODEL; PERSONAL EXPOSURE; PERFORMANCE; PM2.5;
D O I
10.1016/j.buildenv.2021.108398
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Americans spend most of their time indoors at home, but comprehensive characterization of in-home air pollution is limited by the cost and size of reference-quality monitors. We assembled small "Home Health Boxes" (HHBs) to measure indoor PM2.5, PM10, CO2, CO, NO2, and O-3 concentrations using filter samplers and low-cost sensors. Nine HHBs were collocated with reference monitors in the kitchen of an occupied home in Fort Collins, Colorado, USA for 168 h while wildfire smoke impacted local air quality. When HHB data were interpreted using gas sensor manufacturers' calibrations, HHBs and reference monitors (a) categorized the level of each gaseous pollutant similarly (as either low, elevated, or high relative to air quality standards) and (b) both indicated that gas cooking burners were the dominant source of CO and NO2 pollution; however, HHB and reference O-3 data were not correlated. When HHB gas sensor data were interpreted using linear mixed calibration models derived via collocation with reference monitors, root-mean-square error decreased for CO2 (from 408 to 58 ppm), CO (645 to 572 ppb), NO2 (22 to 14 ppb), and O-3 (21 to 7 ppb); additionally, correlation between HHB and reference O-3 data improved (Pearson's r increased from 0.02 to 0.75). Mean 168-h PM2.5 and PM10 concentrations derived from nine filter samples were 19.4 mu g m(-3) (6.1% relative standard deviation [RSD]) and 40.1 mu g m(-3) (7.6% RSD). The 168-h PM2.5 concentration was overestimated by PMS5003 sensors (median sensor/filter ratio = 1.7) and underestimated slightly by SPS30 sensors (median sensor/filter ratio = 0.91).
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [1] Design of A Low-Cost Wireless Indoor Air Quality Sensor Network System
    Abraham, Sherin
    Li, Xinrong
    INTERNATIONAL JOURNAL OF WIRELESS INFORMATION NETWORKS, 2016, 23 (01) : 57 - 65
  • [2] Evaluation of a low-cost multi-channel monitor for indoor air quality through a novel, low-cost, and reproducible platform
    Baldelli A.
    1600, Elsevier Ltd (17):
  • [3] Low-cost multispecies air quality sensor
    Wang, C. M.
    Esse, B. D.
    Lewis, A. C.
    AIR POLLUTION XXIII, 2015, 198 : 105 - 116
  • [4] Design and Development of Low-cost Wireless Sensor Device for Air Quality Networks
    Sharma, Anamika
    Mishra, Brijesh
    Sutaria, Ronak
    Zele, Rajesh
    PROCEEDINGS OF THE 2019 IEEE REGION 10 CONFERENCE (TENCON 2019): TECHNOLOGY, KNOWLEDGE, AND SOCIETY, 2019, : 2345 - 2350
  • [5] Evaluation of sensor-based low-cost devices for Indoor Air Quality (IAQ) measurement
    Schuldt, T.
    Schmidt, F.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2019, 79 (1-2): : 7 - 12
  • [6] Low-cost Indoor Air Quality (IAQ) Platform for Healthier Classrooms in New Zealand: Engineering Issues
    Weyers, Ryan
    Jang-Jaccard, Julian
    Moses, Alfred
    Wang, Yu
    Boulic, Mikael
    Chitty, Chris
    Phipps, Robyn
    Cunningham, Chris
    Olivares, Gustavo
    Arif, Khalid
    Page, Wyatt
    Shekar, Aruna
    Botes, Carli
    Cresswell, Georgie
    Chilcott, Kate
    Withers, Emma
    Delhumeau, Antoine
    Hue, Corentin
    Plagmann, Manfred
    Trompetter, Bill
    Bennett, Julie
    Pierse, Nevil
    Theobald, Chris
    Mansell, Alishia
    Kaua, Doris
    Ponder-Sutton, Agathe
    2017 4TH ASIA-PACIFIC WORLD CONGRESS ON COMPUTER SCIENCE AND ENGINEERING (APWCONCSE 2017), 2017, : 208 - 215
  • [7] Review of low-cost sensors for indoor air quality: Features and applications
    Rodenas Garcia, Milagros
    Spinazze, Andrea
    Branco, Pedro T. B. S.
    Borghi, Francesca
    Villena, Guillermo
    Cattaneo, Andrea
    Di Gilio, Alessia
    Mihucz, Victor G.
    Gomez Alvarez, Elena
    Lopes, Sergio Ivan
    Bergmans, Benjamin
    Orlowski, Cezary
    Karatzas, Kostas
    Marques, Goncalo
    Saffell, John
    Sousa, Sofia I. V.
    APPLIED SPECTROSCOPY REVIEWS, 2022, 57 (9-10) : 747 - 779
  • [8] The Relocation Problem of Field Calibrated Low-Cost Sensor Systems in Air Quality Monitoring: A Sampling Bias
    Tancev, Georgi
    Pascale, Celine
    SENSORS, 2020, 20 (21) : 1 - 14
  • [9] Development of indoor environmental quality index using a low-cost monitoring platform
    Mujan, Igor
    Licina, Dusan
    Kljajic, Miroslav
    Culic, Ana
    Andelkovic, Aleksandar S.
    JOURNAL OF CLEANER PRODUCTION, 2021, 312
  • [10] Design and implementation of a low-cost and multi-parameter indoor air quality detector based on IoT
    Zhao, Liang
    Yao, Yujun
    Huang, Shuai
    Xu, Jieru
    INTERNATIONAL JOURNAL OF COMPUTER APPLICATIONS IN TECHNOLOGY, 2023, 72 (04) : 296 - 307