Development and validation of a liquid chromatography-tandem mass spectrometry method for determination of ibuprofen in human plasma

被引:8
|
作者
Puangpetch, Apichaya [1 ,2 ]
Limrungsikul, Anchalee [3 ]
Prommas, Santirhat [1 ,2 ]
Rukthong, Pattarawit [4 ]
Sukasem, Chonlaphat [1 ,2 ]
机构
[1] Mahidol Univ, Ramathibodi Hosp, Dept Pathol, Div Pharmacogen & Personalized Med,Fac Med, Bangkok 10400, Thailand
[2] Ramathibodi Hosp, Somdech Phra Debaratana Med Ctr SDMC, Lab Pharmacogen, Bangkok 10400, Thailand
[3] Mahidol Univ, Ramathibodi Hosp, Dept Pediat, Fac Med, Bangkok 10400, Thailand
[4] Srinakharinwirot Univ, Fac Pharm, Dept Pharmaceut Technol, Nakornnayok 26120, Thailand
关键词
Liquid chromatography-tandem mass spectrometry; Ibuprofen; Pharmacokinetics; Neonates; PATENT DUCTUS-ARTERIOSUS; PHARMACOLOGICAL DIFFERENCES; ORAL IBUPROFEN; MS/MS METHOD; PHARMACOKINETICS; INDOMETHACIN; ENANTIOMERS; VARIABILITY; DISPOSITION; INVERSION;
D O I
10.1016/j.clinms.2019.10.002
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Ibuprofen is widely used to reduce fever, pain, and inflammation and in the treatment of patent ductus arteriosus (PDA) in preterm infants. However, to study the impact of pharmacokinetics of ibuprofen on the rate of ductus arteriosus closure in humans, a quantitative method is required. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a highly sensitive, accurate, reliable, fast, and simple bioanalytical method. In this study, we developed and utilized an LC-MS/MS method to determine ibuprofen bioavailability. One of the novel aspects of this work is the small specimen volume required for the analysis (i.e., 50 mu L). The calibration curve was linear across a concentration range of 0.15-50 mu g/mL. The coefficient of variation for intra-day and inter-day precision was within 0.78%-7.21% and accuracy was within 97.52%-107.21% of the nominal values for low, medium, and high quality control (QC) concentration levels-QCL, QCM, and QCH (0.45, 9.0, and 40.0 mu g/mL, respectively). For ibuprofen concentrations at the lower limit of quantitation (LLOQ), intra-day and inter-day accuracy were 98.11% and 99.81%, respectively; however, the intra-day and inter-day precision were 1.89% and 5.37%, respectively. The pharmacokinetic study involved 18 neonatal subjects who were grouped into low- or high-dose ibuprofen groups. The median maximum concentration for low- and high-dose regimens were 16.05 (14.21-19.32) and 24.10 (20.63-32.03) mu g/mL, respectively, and the median elimination rate constant was 0.041 (0.026-0.047) and 0.071 (0.050-0.073) h(-1), respectively. Thus, the fully validated LC-MS/MS method was determined to be suitable for analyzing unknown plasma samples for ibuprofen pharmacokinetic, bioavailability, and bioequivalence studies. (C) 2019 The Association for Mass Spectrometry: Applications to the Clinical Lab (MSACL). Published by Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:6 / 12
页数:7
相关论文
共 50 条
  • [31] Determination of captopril in human plasma by liquid chromatography-tandem mass spectrometry
    Gu, Jingkai
    Cui, Yimin
    DRUG METABOLISM REVIEWS, 2006, 38 : 142 - 142
  • [32] Determination of cetirizine in human plasma by liquid chromatography-tandem mass spectrometry
    H. Eriksen
    R. Houghton
    R. Green
    J. Scarth
    Chromatographia, 2002, 55 : S145 - S149
  • [33] Determination of cetirizine in human plasma by liquid chromatography-tandem mass spectrometry
    Eriksen, H
    Houghton, R
    Green, R
    Scarth, J
    CHROMATOGRAPHIA, 2002, 55 (Suppl 1) : S145 - S149
  • [34] Liquid chromatography-tandem mass spectrometry method development and validation for the determination of erlotinib in human plasma and its application in pharmacokinetic study
    Ramarao, N. T.
    Vidyadhara, S.
    Rao, M. V. Basaveswara
    Sasidhar, R. L. C.
    Yadav, R. Surendra
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (12) : 1488 - 1494
  • [35] Determination of tropisetron in human plasma by liquid chromatography-tandem mass spectrometry
    Deng, Pan
    Zhong, Dafang
    Chen, Xiaoyan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) : 848 - 852
  • [36] Determination of voriconazole in human plasma by liquid chromatography-tandem mass spectrometry
    Teng, G-Sh.
    Zhao, L. -Z.
    Li, X.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 (01): : 147 - 152
  • [37] Validation of a chiral liquid chromatography-tandem mass spectrometry method for the determination of pantoprazole in dog plasma
    Chen, Meixia
    Xia, Yu
    Ma, Zhiyu
    Li, Liang
    Zhong, Dafang
    Chen, Xiaoyan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 906 : 85 - 90
  • [38] Development and validation of a liquid chromatography-tandem mass spectrometry assay for determination of raloxifene and its metabolites in human plasma
    Trontelj, Jurij
    Bogataj, Marija
    Marc, Janja
    Mrhar, Ales
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 855 (02): : 220 - 227
  • [39] Development and validation of a liquid chromatography/tandem mass spectrometry method for the determination of DMXAA in human and mouse plasma
    Zhang, Xiaosong
    Zhao, Ming
    Rudek, Michelle A.
    He, Ping
    Vogelstein, Bert
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 217 - 222
  • [40] Development and validation of a sensitive liquid chromatography/tandem mass spectrometry method for the determination of exemestane in human plasma
    Ksycinska, Hanna
    Bus-Kwasnik, Katarzyna
    Szlagowska, Anna
    Rudzki, Piotr J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (21): : 1905 - 1910