摘要
Background: The primary goal of many computer-assisted surgical systems like robotics for total knee arthroplasty (TKA) is to accurately execute a preoperative plan. To assess whether the preoperative plan was executed accurately in 3D, one option is to compare the planned and postoperative implant placement using a preoperative and postoperative CT scan of the patient's limb. This comparison requires a 3D-to-3D surface registration between the preoperative and postoperative 3D bone models and between the planned and postoperative 3D implants. Hence, the present study aimed at validating this measurement technique by determining (I) the anatomical regions that result in the lowest 6-degree of freedom (DoF) errors for 3 D-to-3D surface registration of bone models, (II) the 6-DoF errors for 3D-to-3D surface registration of the implant models, and (III) the 6-DoF of the complete measurement technique. Methods: Four different regions of the femur were tested to determine which one would result in the most accurate 3D-to-3D registration of the bone models using 12 cadaveric lower limb specimens. Next, total knee arthroplasties were performed on six specimens, and the accuracy of the 3D-to-3D implant registration was evaluated against a gold standard registration performed using fiducial markers. Results: The most accurate 3D-to-3D bone registration was obtained when using the largest anatomical regions available after TKA, being the full 3D femur model or the femur model without the distal femur which resulted in root mean square errors within 0.2 mm for translations and 0.2 degrees for rotation. The accuracy of the 3D-to-3D femoral and tibial implant registration was within 0.7 mm for translations and 0.4 degrees-0.6 degrees for rotations, respectively. The accuracy for the overall procedure was within 0.9 mm and 0.6 degrees for both femur and tibia when using femoral regions resulting in accurate 3D-to-3D bone registration. Conclusions: In conclusion, this measurement technique can be used in applications where measurement errors up to 0.9 nun in translations and up to 0.6 degrees in rotations in component placement are acceptable.
引用
收藏
页码:475 / 484
页数:10
相关论文
共 50 条
  • [31] Accuracy of acetabular cup positioning in robotic-assisted total hip arthroplasty: a CT-based evaluation
    Singh, Ashish
    Kumar, Purushotam
    Kalyan, Kanukuntla
    Gundalli, Akash Chandrashekar
    Mane, Sudhir Shankar
    Swarnkar, Himanshu
    Singh, Lavanya
    SICOT-J, 2024, 10
  • [32] A novel CT-based permanent breast seed implant technique
    Kader, H.
    Pham, Y.
    Ansbacher, W.
    Gray, S.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S146 - S146
  • [33] TOTAL KNEE ARTHROPLASTY - TECHNIQUE
    MENDES, DS
    SOUDRY, M
    IUSIM, M
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1980, 16 (02): : 151 - 152
  • [34] Rigid fixation of pelvic tracker essential for accurate cup placement in CT-based navigation total hip arthroplasty
    Hamawaki, Makoto
    Hamada, Hidetoshi
    Uemura, Keisuke
    Takashima, Kazuma
    Mae, Hirokazu
    Nakamura, Nobuo
    Sugano, Nobuhiko
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (04) : 403 - 409
  • [35] Significant differences between manufacturer and surgeon in the accuracy of final component size prediction with CT-based patient-specific instrumentation for total knee arthroplasty
    Davide Cucchi
    Alessandra Menon
    Riccardo Compagnoni
    Paolo Ferrua
    Chiara Fossati
    Pietro Randelli
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 3317 - 3324
  • [36] Significant differences between manufacturer and surgeon in the accuracy of final component size prediction with CT-based patient-specific instrumentation for total knee arthroplasty
    Cucchi, Davide
    Menon, Alessandra
    Compagnoni, Riccardo
    Ferrua, Paolo
    Fossati, Chiara
    Randelli, Pietro
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (11) : 3317 - 3324
  • [37] CT-based and CT-free navigation in total knee arthroplasty - A prospective comparative study with respects to clinical and radiological results
    Martin, A
    von Strempel, A
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2005, 143 (03): : 323 - 328
  • [38] CT-based planning of a single-radius femoral component in total knee arthroplasty using the ROBODOC system
    Hananouchi, Takehito
    Nakamura, Nobuo
    Kakimoto, Akihiro
    Yohsikawa, Hideki
    Sugano, Nobuhiko
    COMPUTER AIDED SURGERY, 2008, 13 (01) : 23 - 29
  • [39] 3D CT-based analysis of the effect of an increasing posterior tibial slope in total knee arthroplasty
    Kamphausen, Marcus
    Geert, Pagenstert
    Valderrabano, I. Victor
    Mueller-Gerbl, Magdalena
    Nowakowski, Andrej M.
    SWISS MEDICAL WEEKLY, 2012, 142 : S2 - S3
  • [40] Relationship between the Accuracy of the Acetabular Cup Angle and BMI in Posterolateral Total Hip Arthroplasty with CT-Based Navigation
    Ishikura, Hisatoshi
    Nakamura, Masaki
    Nakamura, Shigeru
    Tanaka, Takeyuki
    Kawano, Hirotaka
    Tanaka, Sakae
    MEDICINA-LITHUANIA, 2022, 58 (07):