On-site H2O2 electro-generation process combined with ultraviolet: A promising approach for odorous compounds purification in drinking water system

被引:30
|
作者
Zhao, Yiying [1 ]
Deng, Ning [1 ]
Fan, Zhiheng [1 ]
Hu, Zhong-Ting [2 ]
Fan, Lili [1 ]
Zhou, Jizhi [3 ]
Huang, Xin [1 ]
机构
[1] Shanghai Univ, Sch Environm & Chem Engn, Shanghai 200444, Peoples R China
[2] Shanghai Univ, Sch Econ, Shanghai 200444, Peoples R China
[3] Zhejiang Univ Technol ZJUT, Coll Environm, Hangzhou 310014, Peoples R China
基金
美国国家科学基金会;
关键词
Hydrogen peroxide; On-site generation; Advanced oxidation process; Taste and odor (T&O) compounds; Trichloroanisoles; HYDROGEN-PEROXIDE; OXYGEN REDUCTION; ELECTROSYNTHESIS; CARBON; OXIDATION; DEGRADATION; HYDROXYL; REMOVAL; QUALITY; YIELD;
D O I
10.1016/j.cej.2021.132829
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The on-site generation of hydrogen peroxide (H2O2) attracts much attention for advanced oxidation processes (AOPs) in water treatment. In this work, we reported a novel on-site H2O2 generation reactor combined with ultraviolet (UV) for taste and odor (T&O) compounds removal in drinking water purification systems. The reactor is equipped with a gas diffusion electrode (GDE) accompanied by a proton-conducting solid electrolyte. In this reactor, GDE is used to improve the oxygen transfer efficiency. The porous solid electrolyte is selected for the proton and electron conduction instead of an electrolyte solution, which is crucial for producing pure H2O2 solution. The production rate and concentration of H2O2 can be controlled through adjusting the applied current efficiency and the flow rate of deionized water in a solid chamber. Meanwhile, this system exhibits long-term stability during a continuous operation for 96 h. For the application of the system, the single-cell was assembled into cell stacks, which improved the H2O2 concentration from 780.9 to 2301.3 mg.L-1, along with the energy consumption reduced from 23.81 to 6.67 kWh.kg(-1) under the applied current density of 30 mA.cm(-2). To evaluate the water purification performance of this system, the oxidation degradation of 2,4,6-trichlomanisoles (TCA) was conducted using the on-site H2O2 generation process under both static and dynamic flow conditions combined with UV light. The degradation rate of TCA was >95% with its initial concentration of 1 mu g.L-1 under the hydraulic retention time from 10 to 40 min(-1) and H2O2 dosage from 10 to 100 mg.L-1. Meanwhile, almost no residual H2O2 was detected after the degradation process. This study proposed a promising device for drinking water purification.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Lignin combined with polypyrrole as a renewable cathode material for H2O2 generation and its application in the electro-Fenton process for azo dye removal
    Huang, Hailan
    Han, Chunlei
    Wang, Guanwen
    Feng, Chunhua
    ELECTROCHIMICA ACTA, 2018, 259 : 637 - 646
  • [22] Catalytic degradation of amoxicillin from water by a combined system of ultrasound/H2O2/KI
    Zhang, Yan
    Gao, Wenning
    Li, Dongmin
    Peng, Yingying
    Yuan, Honglei
    Sun, Xianke
    ENVIRONMENTAL TECHNOLOGY, 2024, 45 (04) : 695 - 704
  • [23] Fabrication of sandwich-like super-hydrophobic cathode for the electro-Fenton degradation of cefepime: H2O2 electro-generation, degradation performance, pathway and biodegradability improvement
    Chu, Yanyang
    Su, Hongzhao
    Liu, Chang
    Zheng, Xianglei
    CHEMOSPHERE, 2022, 286
  • [24] A Novel Electro-Fenton Process with H2O2 Generation in a Rotating Disk Reactor for Organic Pollutant Degradation
    Yu, Fangke
    Zhou, Minghua
    Zhou, Lei
    Peng, Rudan
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2014, 1 (07): : 320 - 324
  • [25] Electro-Fenton process for wastewater treatment: From selective H2O2 generation to efficient •OH conversion
    Yin, Jialong
    Zhang, Heng
    Luo, Mengfan
    Zhao, Jia
    Zhou, Xin
    Wang, Fengchen
    Zhou, Hongyu
    Yuan, Yue
    Liu, Yang
    Shi, Yanbiao
    Xiong, Zhaokun
    Lai, Bo
    CHEMICAL ENGINEERING JOURNAL, 2025, 507
  • [26] Organic Contaminant Abatement in Reclaimed Water by UV/H2O2 and a Combined Process Consisting of O3/H2O2 Followed by UV/H2O2: Prediction of Abatement Efficiency, Energy Consumption, and Byproduct Formation
    Lee, Yunho
    Gerrity, Daniel
    Lee, Minju
    Gamage, Sujanie
    Pisarenko, Aleksey
    Trenholm, Rebecca A.
    Canonica, Silvio
    Snyder, Shane A.
    von Gunten, Urs
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2016, 50 (07) : 3809 - 3819
  • [27] Coupling effect of nitrogen-doped carbon black and carbon nanotube in assembly gas diffusion electrode for H2O2 electro-generation and recalcitrant pollutant degradation
    Lu, Jun
    Liu, Xiaochen
    Chen, Quanyuan
    Zhou, Juan
    SEPARATION AND PURIFICATION TECHNOLOGY, 2021, 265 (265)
  • [28] Performance of A Combination Process of UV/H2O2/Micro-Aeration for Oxidation of Dichloroacetic Acid in Drinking Water
    Chu, WenHai
    Gao, N. Y.
    Deng, Y.
    CLEAN-SOIL AIR WATER, 2009, 37 (03) : 233 - 238
  • [29] Degradation of sulfamethoxazole in water by a combined system of ultrasound/PW12/KI/H2O2
    Zhang, Xin
    Wang, Jing
    Duan, Baorong
    Jiang, Song
    SEPARATION AND PURIFICATION TECHNOLOGY, 2021, 270
  • [30] Electrochemical generation of H2O2: Development of a reactor with carbon catalysts for portable low-cost water purification
    Chen, Zhihua
    Chen, Shucheng
    Siahrostami, Samira
    Chakthranont, Pongkarn
    Hahn, Christopher
    Nordlund, Dennis
    Sokaras, Dimosthenis
    Norskov, Jens
    Bao, Zhenan
    Jaramillo, Thomas
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253