On-site H2O2 electro-generation process combined with ultraviolet: A promising approach for odorous compounds purification in drinking water system

被引:30
|
作者
Zhao, Yiying [1 ]
Deng, Ning [1 ]
Fan, Zhiheng [1 ]
Hu, Zhong-Ting [2 ]
Fan, Lili [1 ]
Zhou, Jizhi [3 ]
Huang, Xin [1 ]
机构
[1] Shanghai Univ, Sch Environm & Chem Engn, Shanghai 200444, Peoples R China
[2] Shanghai Univ, Sch Econ, Shanghai 200444, Peoples R China
[3] Zhejiang Univ Technol ZJUT, Coll Environm, Hangzhou 310014, Peoples R China
基金
美国国家科学基金会;
关键词
Hydrogen peroxide; On-site generation; Advanced oxidation process; Taste and odor (T&O) compounds; Trichloroanisoles; HYDROGEN-PEROXIDE; OXYGEN REDUCTION; ELECTROSYNTHESIS; CARBON; OXIDATION; DEGRADATION; HYDROXYL; REMOVAL; QUALITY; YIELD;
D O I
10.1016/j.cej.2021.132829
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The on-site generation of hydrogen peroxide (H2O2) attracts much attention for advanced oxidation processes (AOPs) in water treatment. In this work, we reported a novel on-site H2O2 generation reactor combined with ultraviolet (UV) for taste and odor (T&O) compounds removal in drinking water purification systems. The reactor is equipped with a gas diffusion electrode (GDE) accompanied by a proton-conducting solid electrolyte. In this reactor, GDE is used to improve the oxygen transfer efficiency. The porous solid electrolyte is selected for the proton and electron conduction instead of an electrolyte solution, which is crucial for producing pure H2O2 solution. The production rate and concentration of H2O2 can be controlled through adjusting the applied current efficiency and the flow rate of deionized water in a solid chamber. Meanwhile, this system exhibits long-term stability during a continuous operation for 96 h. For the application of the system, the single-cell was assembled into cell stacks, which improved the H2O2 concentration from 780.9 to 2301.3 mg.L-1, along with the energy consumption reduced from 23.81 to 6.67 kWh.kg(-1) under the applied current density of 30 mA.cm(-2). To evaluate the water purification performance of this system, the oxidation degradation of 2,4,6-trichlomanisoles (TCA) was conducted using the on-site H2O2 generation process under both static and dynamic flow conditions combined with UV light. The degradation rate of TCA was >95% with its initial concentration of 1 mu g.L-1 under the hydraulic retention time from 10 to 40 min(-1) and H2O2 dosage from 10 to 100 mg.L-1. Meanwhile, almost no residual H2O2 was detected after the degradation process. This study proposed a promising device for drinking water purification.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] On-site electro-generation of H2O2 combined with UV process: Multiple pharmaceutically active compounds degradation for drinking water systems
    Guimaraes, Raissa Engroff
    Albornoz, Louidi Lauer
    Beltrame, Thiago Favarini
    Gabaldon, Montserrat Garcia
    Borba, Fernando Henrique
    da Silva, Salatiel Wohlmuth
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 361
  • [2] Electro-generation of H2O2 and abatement of organic pollutant in water by an electro-Fenton process in a microfluidic reactor
    Scialdone, Onofrio
    Galia, Alessandro
    Sabatino, Simona
    ELECTROCHEMISTRY COMMUNICATIONS, 2013, 26 : 45 - 47
  • [3] Effect of air pressure on the electro-generation of H2O2 and the abatement of organic pollutants in water by electro-Fenton process
    Scialdone, Onofrio
    Galia, Alessandro
    Gattuso, Carolina
    Sabatino, Simona
    Schiavo, Benedetto
    ELECTROCHIMICA ACTA, 2015, 182 : 775 - 780
  • [4] New insights into the surface-dependent activity of graphitic felts for the electro-generation of H2O2
    Zhou, Jing
    An, Xiaoqiang
    Lan, Huachun
    Liu, Huijuan
    Qu, Jiuhui
    APPLIED SURFACE SCIENCE, 2020, 509
  • [5] Drastic enhancement of H2O2 electro-generation by pulsed current for ibuprofen degradation: Strategy based on decoupling study on H2O2 decomposition pathways
    Zhou, Wei
    Gao, Jihui
    Ding, Yani
    Zhao, Haiqian
    Meng, Xiaoxiao
    Wang, Yan
    Kou, Kaikai
    Xu, Yiqun
    Wu, Shaohua
    Qin, Yukun
    CHEMICAL ENGINEERING JOURNAL, 2018, 338 : 709 - 718
  • [7] Organic Pollutant Degradation in Water by the Vacuum-Ultraviolet/Ultraviolet/H2O2 Process: Inhibition and Enhancement Roles of H2O2
    Li, Mengkai
    Li, Wentao
    Bolton, James R.
    Blatchley, Ernest R., III
    Qang, Zhimin
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (02) : 912 - 918
  • [8] The UV/H2O2 process based on H2O2 in-situ generation for water disinfection
    Zhao, Qian
    Li, Nan
    Liao, Chengmei
    Tian, Lili
    An, Jingkun
    Wang, Xin
    JOURNAL OF HAZARDOUS MATERIALS LETTERS, 2021, 2
  • [9] Melamine-derived carbon electrode for efficient H2O2 electro-generation (vol 261, pg 375, 2018)
    Zhu, Yingshi
    Qiu, Shan
    Ma, Fang
    Li, Guojun
    Deng, Fengxia
    Zheng, Yanshi
    ELECTROCHIMICA ACTA, 2019, 305 : 64 - 64
  • [10] Generation of H2O2 by on-site activation of molecular dioxygen for environmental remediation applications: A review
    Pi, Liu
    Cai, Jianhua
    Xiong, Lili
    Cui, Jiaxin
    Hua, Helin
    Tang, Dingding
    Mao, Xuhui
    CHEMICAL ENGINEERING JOURNAL, 2020, 389