The accuracy of a commercial spectrophotometer with single integrating sphere for measuring optical properties of turbid sample

被引:4
|
作者
Zhang, Yang [1 ]
Wen, Xiang [1 ]
Xu, ZhuDi [1 ]
Zhu, Dan [1 ]
机构
[1] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Britton Chance Ctr Biomed Photon, Sch Life Sci & Technol, Wuhan 430074, Peoples R China
关键词
Single Integrating-sphere; Optical Properties; Turbid Medium; Inverse Adding-doubling Method; WAVELENGTH RANGE; SCATTERING; TISSUES;
D O I
10.1117/12.841821
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A commercial spectrophotometer with an integrating sphere is widely used to measure the spectra of transmittance and reflectance of turbid sample, and then the optical properties can be deduced by inverse adding-doubling algorithm. Unfortunately, the accuracy of the measurement is not been elucidated completely. What's more, for the system, there still exists some other limits, i.e., the incident light is not collimated and size of light spot is too large compared with the sample port. Thus, the purpose of our study is to evaluate the accuracy of the commercial spectrophotometer with an integrating sphere for measuring optical properties of tissue phantom. Two phantom materials, Intralipid and Evans blue, and the mixture of these two, were chosen for the experiments. Mie theory was also introduced to calculate the reduced scattering coefficient according to the particle size distribution. The results show that the phantom measurement in conjunction with IAD algorithm enable the determination of scattering coefficient mu s' to be better than 5% accuracy, absorption coefficient mu a to be better than 10% accuracy when the optical depth of sample is between 1 and 10, and the albedo is bigger than 0.4. For scattering of samples during 1-5 mm(-1), the error of mu s' is smaller than 4%; whereas for absorbing of samples >0.4 mm(-1), the maximum error is smaller than 8.3%. Therefore, spectrophotometer with an integrating sphere technique combined IAD algorithm is applicable for the measurements of optical properties for most tissue, and its repeatability and accuracy is good in proper scope of the optical depth and albedo.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Polystyrene Microsphere Optical Properties by Kubelka-Munk and Diffusion Approximation with a Single Integrating Sphere System: A Comparative Study
    Shahin, Ali
    Bachir, Wesam
    El-Daher, Moustafa Sayem
    JOURNAL OF SPECTROSCOPY, 2019, 2019
  • [42] Determination of the optical properties of turbid media from a single Monte Carlo simulation
    Kienle, A
    Patterson, MS
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (10): : 2221 - 2227
  • [43] Characterization and optimization of an integrating sphere based detector for the estimation of tissue optical properties
    Moscu, Diana F.
    Hayward, Joseph E.
    Farrell, Thomas J.
    Patterson, Michael S.
    NOVEL OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS III, 2007, 6631
  • [44] High-accuracy measurement of linearity of optical detectors based on flux addition of LEDs in an integrating sphere
    Shin, Dong-Joo
    Park, Seongchong
    Jeong, Ki-Lyong
    Park, Seung-Nam
    Lee, Dong-Hoon
    METROLOGIA, 2014, 51 (01) : 25 - 32
  • [45] Estimation of optical parameters and fluence rate distribution in biological tissues via a single integrating sphere optical setup
    Hamdy, Omnia
    Fathy, Mahmoud
    Al-Saeed, Tarek A.
    El-Azab, Jala
    Solouma, Nahed H.
    OPTIK, 2017, 140 : 1004 - 1009
  • [46] Double integrating sphere measurements for estimating optical properties of pig subcutaneous adipose tissue
    Zamora-Rojas, Eduardo
    Aernouts, Ben
    Garrido-Varo, Ana
    Perez-Marin, Dolores
    Emilio Guerrero-Ginel, Jose
    Saeys, Wouter
    INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2013, 19 : 218 - 226
  • [47] Alternative Measurement Configurations for Extracting Bulk Optical Properties Using an Integrating Sphere Setup
    Thennadil, Suresh N.
    Chen, Yi-chieh
    APPLIED SPECTROSCOPY, 2017, 71 (02) : 224 - 237
  • [48] Estimation of Optical Parameters of Chicken Liver Tissue via Single Integrating-Sphere System
    Pehlivanoz, Bahar
    Arslan, Halil
    2018 MEDICAL TECHNOLOGIES NATIONAL CONGRESS (TIPTEKNO), 2018,
  • [49] Single-beam integrating sphere spectrophotometer for reflectance and transmittance measurements versus angle of incidence in the solar wavelength range on diffuse and specular samples
    Nostell, Per
    Roos, Arne
    Ronnow, Daniel
    Review of Scientific Instruments, 70 (05): : 2481 - 2494
  • [50] Single-beam integrating sphere spectrophotometer for reflectance and transmittance measurements versus angle of incidence in the solar wavelength range on diffuse and specular samples
    Nostell, P
    Roos, A
    Rönnow, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (05): : 2481 - 2494