Assessment of ankle plantar flexor neuromuscular properties: A reliability study

被引:2
|
作者
Oskouei, Sanam Tavakkoli [1 ]
Malliaras, Peter [1 ]
Hill, Keith D. [2 ]
Garofolini, Alessandro [3 ]
Clark, Ross [4 ]
Perraton, Luke [1 ]
机构
[1] Monash Univ, Sch Primary & Allied Hlth Care, Fac Med Nursing & Hlth Sci, Dept Physiotherapy, Clayton, Vic, Australia
[2] Monash Univ, Ageing & Independent Living RAIL Res Ctr, Clayton, Vic, Australia
[3] Victoria Univ, Inst Hlth & Sport IHES, Melbourne, Vic, Australia
[4] Univ Sunshine Coast, Sch Hlth & Behav Sci, Sippy Downs, Qld, Australia
关键词
Ankle joint; Muscle strength; Rate of force development; Neuromuscular performance; Reproducibility; MUSCLE-CONTRACTION; ELECTROMECHANICAL DELAY; TORQUE DEVELOPMENT; FORCE DEVELOPMENT; RATIO SCALE; STEADINESS; YOUNG; ASSOCIATION; VARIABILITY; PERFORMANCE;
D O I
10.1016/j.jelekin.2021.102603
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study aimed to determine test-retest reliability of ankle plantar flexor neuromuscular properties in healthy people to improve understanding of additional measurement and analysis procedures that may be used in outcome assessment. Ten healthy participants (age 29.60 +/- 5.36 years) volunteered. Isometric torque(max), rate of torque development (RTD), rate of electromyography rise (RER), impulse, electromechanical delay (EMD), torque steadiness, and torque sensing were obtained during two testing sessions 60 min apart. ICC values ranged from 0.81 to 0.99, indicating good to excellent test-retest reliability. Lower bands of the 95% CIs were all above 0.75 apart from the early phase measures (<= 50 ms) derived from explosive torque-time and EMG-time curves, which were between 0.32 and 0.73, indicating poor to moderate reliability. Heteroscedasticity was observed for RTD, impulse, and EMD. LOA as a function of the mean (X-) for these measures ranged from mean(difference) +/- 0.25X(-) to +/- 0.68X(-). EMD showed excellent reliability (ICC = 0.90; 95% CI [0.63, 0.98]). Torque sensing and torque steadiness showed good reliability (0.81 <= ICC <= 0.89). Thus, ankle plantar flexor neuromuscular properties showed good to excellent test-retest reliability. However, reliability of measures in the early phase of muscle contraction were consistently lower than the late phase.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Ankle and Plantar Flexor Muscle–Tendon Unit Function in Sprinters: A Narrative Review
    Evan D. Crotty
    Laura-Anne M. Furlong
    Andrew J. Harrison
    Sports Medicine, 2024, 54 : 585 - 606
  • [22] Eccentric plantar-flexor torque deficits in participants with functional ankle instability
    Fox, Jason
    Docherty, Carrie L.
    Schrader, John
    Applegate, Trent
    JOURNAL OF ATHLETIC TRAINING, 2008, 43 (01) : 51 - 54
  • [23] Effect of quadriceps and ankle plantar flexor muscle fatigue on balance of elderly women
    Islami, Fatemeh
    Fallah, Zynolabedin
    Mahdavi, Soolmaz
    Hesari, Amin Farzaneh
    Janani, Hamid
    HEALTHMED, 2012, 6 (03): : 875 - 878
  • [24] Effects of imagery motor training on torque production of ankle plantar flexor muscles
    Zijdewind, I
    Toering, ST
    Bessem, B
    van der Laan, O
    Diercks, RL
    MUSCLE & NERVE, 2003, 28 (02) : 168 - 173
  • [25] Effects of Age and Localized Muscle Fatigue on Ankle Plantar Flexor Torque Development
    King, Gregory W.
    Stylianou, Antonis P.
    Kluding, Patricia M.
    Jernigan, Stephen D.
    Luchies, Carl W.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2012, 35 (01) : 8 - 14
  • [26] Neuromuscular fatigue induced by alternating isometric contractions of the ankle plantar and dorsiflexors
    Kennedy, Ashleigh
    Hug, Francois
    Bilodeau, Martin
    Sveistrup, Heidi
    Guevel, Arnaud
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2011, 21 (03) : 471 - 477
  • [27] Reliability of isokinetic tests of velocity- and contraction intensity-dependent plantar flexor mechanical properties
    Pinto, Matheus D.
    Wilson, Cody J.
    Kay, Anthony D.
    Blazevich, Anthony J.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2021, 31 (05) : 1009 - 1025
  • [28] Assessment the reliability of ultrasonography in the imaging of the plantar fascia: a comparative study
    Wu, Jing
    Zhang, Yuan-zhi
    Gao, Yang
    Luo, Tian-you
    BMC MEDICAL IMAGING, 2019, 19 (01)
  • [29] Assessment the reliability of ultrasonography in the imaging of the plantar fascia: a comparative study
    Jing Wu
    Yuan-zhi Zhang
    Yang Gao
    Tian-you Luo
    BMC Medical Imaging, 19
  • [30] Validity and intrarater reliability of a novel device for assessing Plantar flexor strength
    O'Neill, Seth
    Weeks, Alice
    Norgaard, Jens Eg
    Jorgensen, Martin Gronbech
    PLOS ONE, 2023, 18 (03):