Comparative effectiveness of dried plasma HIV-1 viral load testing in Brazil using ViveST for sample collection

被引:11
|
作者
Zanoni, Michelle [2 ]
Cortes, Rodrigo [2 ]
Diaz, Ricardo S. [2 ,3 ]
Sucupira, M. Cecilia [2 ]
Ferreira, Denise
Inocencio, Lilian A.
Vilhena, Cintia [2 ,3 ]
Loveday, Clive [4 ]
Lloyd, R. M., Jr. [5 ]
Holodniy, M. [1 ,6 ]
机构
[1] VA Palo Alto Healthcare Syst, Palo Alto, CA 94304 USA
[2] Univ Fed Sao Paulo, Retrovirol Lab, Sao Paulo, Brazil
[3] Lab Ctr Genomas, Sao Paulo, Brazil
[4] ICVC Charitable Trust HQ, London, England
[5] Res Think Tank Inc, Buford, GA USA
[6] Stanford Univ, Div Infect Dis & Geog Med, Stanford, CA 94305 USA
关键词
HIV; Viral load; Sample collection; Dried blood; HUMAN-IMMUNODEFICIENCY-VIRUS; BLOOD SPOTS; STORAGE-CONDITIONS; TYPE-1; RNA; QUANTIFICATION; SPECIMENS; DIAGNOSIS; ASSAY;
D O I
10.1016/j.jcv.2010.08.017
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Utilization of dried plasma for HIV-1 viral load testing would significantly decrease sample shipping costs. Objectives: To describe the precision and reproducibility of ViveST (R) (ST) as a transportation method for shipping specimens for HIV-1 viral load (VL) testing. Study design: Thirty clinical plasma samples were used to generate replicate samples with HIV VL values of 4 log(10), 3 log(10) and 2 log(10) copies/mL for reproducibility testing and an additional 299 samples with HIV VL <50 copies/mL (99); 1.7 log(10) to 3.99 log(10) (100); and 4 log(10) to 5.99 log(10)/mL (100) were used to compare ViveST to frozen plasma samples using the VERSANT (R) HIV-1 RNA 3.0 Assay. Results were compared using Student t-test, Pearson correlation and Bland-Altman analyses. Results: Meanintra-assay variance among frozen and dried plasma triplicates was 0.15 log(10) and 0.09 log(10) copies/mL respectively (n = 10, P = NS). Compared to frozen plasma, there was a mean reduction of 0.3 log(10), 0.27 log(10), and 0.35 log(10) copies/mL at the 4 log(10), 3 log(10), and 2 log(10) copy/mL samples respectively (n = 30, all comparisons, P<0.01). Overall correlation between 299 frozen and ViveST samples was r = 0.97, where 12 of 99 undetectable frozen VL were positive with ST, and 12 of 200 frozen detectable VL were undetectable with ViveST (mean VL 2.1, 1.9 log(10) copies/mL respectively). Conclusions: HIV-1 viral load results using ViveST were reproducible, correlated well with frozen plasma, though yielding minimally lower values. Our data suggest that dried plasma for HIV-1 VL testing using ViveST has promise for use in HIV clinical practice. Published by Elsevier B.V.
引用
收藏
页码:245 / 248
页数:4
相关论文
共 50 条
  • [21] HIV-1 viral load testing and Roche diagnostics assay kits
    Yen-Lieberman, B
    INFECTIONS IN MEDICINE, 2001, 18 (09) : 417 - +
  • [22] Self-collected or staff-collected dried blood spot specimens for HIV-1 viral load testing
    Paraskevis, Dimitrios
    Masenga, Sepiso K.
    AIDS, 2024, 38 (15) : 2098 - 2099
  • [23] Genetic diversity of HIV-1 subtype F from Brazil: failure of HIV-1 viral load testing based on molecular biology amplification methods
    Mercado, JMM
    Di Dio, R
    Pradal, MG
    AIDS, 1999, 13 (15) : 2183 - 2185
  • [24] Comparative evaluation of the VERSANT® HIV-1 RNA 1.0 kinetic PCR molecular system (kPCR) for the quantification of HIV-1 plasma viral load
    Ruelle, Jean
    Jnaoui, Karima
    Lefevre, Isabelle
    Lamarti, Najet
    Goubau, Patrick
    JOURNAL OF CLINICAL VIROLOGY, 2009, 44 (04) : 297 - 301
  • [25] Feasibility of using dried blood spots for HIV viral load testing among HIV-infected individuals in Thailand using QIAGEN QIAsymphony-artus HIV-1 platform
    Thepbundit, Viraporn
    Ngo-Giang-Huong, Nicole
    Salvadori, Nicolas
    Laolue, Auswin
    Kunyanone, Naowarat
    Sata-un, Jaggrit
    Jourdain, Gonzague
    Sirirungsi, Wasna
    Khamduang, Woottichai
    JOURNAL OF MEDICAL VIROLOGY, 2019, 91 (09) : 1652 - 1659
  • [26] Quantification of infectious HIV-1 plasma viral load using a boosted in vitro infection protocol
    Rusert, P
    Fischer, M
    Joos, B
    Leemann, C
    Kuster, H
    Flepp, M
    Bonhoeffer, S
    Günthard, HF
    Trkola, A
    VIROLOGY, 2004, 326 (01) : 113 - 129
  • [27] Using Plasma Viral Load to Guide Antiretroviral Therapy Initiation to Prevent HIV-1 Transmission
    Murnane, Pamela M.
    Hughes, James P.
    Celum, Connie
    Lingappa, Jairam R.
    Mugo, Nelly
    Farquhar, Carey
    Kiarie, James
    Wald, Anna
    Baeten, Jared M.
    PLOS ONE, 2012, 7 (11):
  • [28] Performance of the Abbott Realtime HIV-1: An automated assay for quantification of HIV-1 viral load in plasma.
    Abravaya, K
    Tang, N
    Huang, S
    Cloherty, G
    Mak, W
    Salituro, J
    Robinson, J
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2005, 7 (05): : 670 - 670
  • [29] HIV-1 viral diversity and its implications for viral load testing: review of current platforms
    Luft, LeeAnne M.
    Gill, M. John
    Church, Deirdre L.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2011, 15 (10) : E661 - E670
  • [30] Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece
    Antigoni Katsoulidou
    Chrysoula Rokka
    Catherine Issaris
    Catherine Haida
    Kimon Tzannis
    Vana Sypsa
    Maria Detsika
    Dimitrios Paraskevis
    Angelos Hatzakis
    Virology Journal, 8