Luciferase-based GloSensor™ cAMP assay: Temperature optimization and application to cell-based kinetic studies

被引:12
|
作者
Wang, Fang, I [1 ]
Ding, Gucci [1 ]
Ng, Garmen S. [1 ]
Dixon, S. Jeffrey [1 ]
Chidiac, Peter [1 ]
机构
[1] Univ Western Ontario, Schulich Sch Med & Dent, Dept Physiol & Pharmacol, London, ON N6A 5C1, Canada
基金
加拿大健康研究院;
关键词
GloSensor; GPCRs; Drug discovery; Optimization; High-throughput screening; LINKED-IMMUNOSORBENT-ASSAY; CYCLIC-AMP; ADENOSINE; BIOLUMINESCENCE; RECEPTOR; IDENTIFICATION; BIOSENSORS; TOOLS;
D O I
10.1016/j.ymeth.2021.10.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
G protein-coupled receptors (GPCRs) are an important receptor superfamily and common therapeutic targets. The second messenger cyclic adenosine monophosphate (cAMP) is a key mediator in many GPCR signaling pathways. Monitoring intracellular cAMP levels can help identify orthosteric agonists and antagonists, as well as allosteric modulators. In this regard, luminescence-based biosensors have revolutionized our ability to monitor GPCR signaling kinetics. The GloSensor (TM) cAMP assay enables real-time monitoring of signaling downstream of many GPCRs. However, it is crucial to optimize assay conditions such as temperature. As well, it has not been reported whether the effects of temperature on biosensor activity are reversible. Here, we describe the temperature sensitivity and reversibility of the GloSensor (TM) cAMP assay, and which GloSensor (TM) version is optimal for measuring cytosolic cAMP. We also present a detailed protocol for monitoring cAMP levels in live cells expressing endogenous or exogenous GPCRs. Temperature optimization studies were carried out using HEK293H cells transiently transfected with the adenosine receptor Ala and the GloSensor (TM) plasmid (pGloSensor-20F or -22F). We found that preincubation and luminescence reading at room temperature were optimal as compared to higher temperatures. As well, the GloSensor-22F biosensor had a superior signal-to-background ratio and the effect of temperature on biosensor activity was reversible. However, thermal instability of the biosensor may pose a problem for in vivo studies. Nevertheless, the GloSensor (TM) cAMP assay can be applied to analyze signaling by a wide range of GPCRs for drug discovery purposes.
引用
收藏
页码:249 / 258
页数:10
相关论文
共 50 条
  • [41] Validating a Firefly Luciferase-Based High-Throughput Screening Assay for Antimalarial Drug Discovery
    Che, Pulin
    Cui, Long
    Kutsch, Olaf
    Cui, Liwang
    Li, Qianjun
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2012, 10 (01) : 61 - 68
  • [42] Quantitative analysis of organophosphorus pesticides in freshwater using an optimized firefly luciferase-based coupled bioluminescent assay
    Marques, S. M.
    Esteves da Silva, J. C. G.
    LUMINESCENCE, 2014, 29 (04) : 378 - 385
  • [43] Split luciferase-based assay to detect botulinum neurotoxins using hiPSC-derived motor neurons
    Laurent Cotter
    Feifan Yu
    Sylvain Roqueviere
    Juliette Duchesne de Lamotte
    Johannes Krupp
    Min Dong
    Camille Nicoleau
    Communications Biology, 6
  • [44] Cell-based assay for β-secretase activity
    Oh, M
    Kim, SY
    Oh, YS
    Choi, DY
    Sin, HJ
    Jung, IM
    Park, WJ
    ANALYTICAL BIOCHEMISTRY, 2003, 323 (01) : 7 - 11
  • [45] Allergan and Cell-Based Assay for BOTOX
    不详
    JOURNAL OF DRUGS IN DERMATOLOGY, 2011, 10 (08) : 938 - 938
  • [46] Rapid and sensitive detection of retrovirus entry by using a novel luciferase-based content-mixing assay
    Kolokoltsov, AA
    Davey, RA
    JOURNAL OF VIROLOGY, 2004, 78 (10) : 5124 - 5132
  • [47] A self-assembling split Nano luciferase-based assay for investigating Pseudomonas syringae effector secretion
    Pei Miao
    Jian-Min Zhou
    Wei Wang
    Stress Biology, 4
  • [48] A cell-based assay for mouse prions
    Weissmann, C
    Vaccine Cell Substrates 2004, 2006, 123 : 181 - 181
  • [49] Development of a cell-based corin assay
    Wunder, F.
    Lambertz, P.
    Theisen, L.
    Garvie, C.
    MacDonald, B.
    Elowe, N.
    Zubov, D.
    Kaushik, V.
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2018, 391 : S40 - S40
  • [50] Cell-based assay utilization is on the upswing
    Sellappan, Shankar
    GENETIC ENGINEERING & BIOTECHNOLOGY NEWS, 2008, 28 (08): : 18 - 18