This paper presents energy and exergy assessments of a new integrated system with different psychrometric processes for HVAC&R applications. The mass, energy, entropy and exergy balance equations for all system components and processes are developed for analysis and performance assessment purposes. In addition, a novel integrated system with psychrometric processes is proposed and thermodynamically analysed. Both energy and exergy efficiencies for individual components, sub-processes and the integrated system under different conditions and capacities are defined and determined. Parametric studies are conducted by varying dead state properties and operating conditions to investigate their effects on the system performance. The results show that the energy and exergy efficiencies of the integrated system become 18.6% and 33.31% respectively. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:159 / 167
页数:9
相关论文
共 50 条
  • [41] Development of building thermal environment emulator to evaluate the performance of the HVAC system operation
    Togashi, Eisuke
    Miyata, Masato
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2019, 12 (05) : 663 - 684
  • [42] The performance of the integrated rural development program in India: An assessment
    Paul, S
    DEVELOPING ECONOMIES, 1998, 36 (02): : 117 - 131
  • [43] Development of an integrated total quality management and performance measurement system for self-assessment: A method
    Pun, KF
    TOTAL QUALITY MANAGEMENT, 2002, 13 (06): : 759 - 777
  • [44] Energy conservation effect of new HVAC system for condominiums with solar collectors integrated with the balcony handrail
    Yoshie, Ryuichiro
    Satake, Akira
    Mochida, Akashi
    Kato, Shinsuke
    Yoshino, Hiroshi
    ENERGY AND BUILDINGS, 2006, 38 (11) : 1360 - 1367
  • [45] AN INTEGRATED PERFORMANCE MEASURE APPROACH FOR SYSTEM RELIABILITY ASSESSMENT
    Wang, Zequn
    Wang, Pingfeng
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2014, VOL 2B, 2014,
  • [46] Exergetic performance assessment of an integrated solar energy system
    Acar, Canan
    Dincer, Ibrahim
    INTERNATIONAL JOURNAL OF EXERGY, 2016, 19 (02) : 161 - 172
  • [47] ClassifyR: an R package for performance assessment of classification with applications to transcriptomics
    Strbenac, Dario
    Mann, Graham J.
    Ormerod, John T.
    Yang, Jean Y. H.
    BIOINFORMATICS, 2015, 31 (11) : 1851 - 1853
  • [48] The integrated development and environmental additionality assessment system (IDEAAS)
    Flamos, A
    Psarras, J
    Samouilidis, JE
    NEW AND RENEWABLE ENERGY TECHNOLOGIES FOR SUSTAINABLE DEVELOPMENT, 2004, : 3 - 24
  • [49] INTEGRATED SYSTEM ARCHITECTURE DEVELOPMENT FRAMEWORK AND COMPLEXITY ASSESSMENT
    Dalvi, Akshay S.
    El-Mounayri, Hazim
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 9, 2021,
  • [50] Integrated CO2 system with HVAC and hot water for hotels: Field measurements and performance evaluation
    Smitt, S.
    Tolstorebrov, I
    Hafner, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 116 : 59 - 69