Development and performance assessment of a new integrated system for HVAC&R applications

被引:11
|
作者
Ghosh, Sayantan [1 ]
Dincer, Ibrahim [1 ,2 ]
机构
[1] Univ Ontario, Inst Technol, Fac Engn & Appl Sci, Oshawa, ON L1H 7K4, Canada
[2] KFUPM, Dept Mech Engn, Dhahran 31261, Saudi Arabia
基金
加拿大自然科学与工程研究理事会;
关键词
Psychrometrics; HVAC&R; Exergy; Energy; Efficiency; Integrated system; EXERGY ANALYSES; ENERGY;
D O I
10.1016/j.energy.2014.11.057
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents energy and exergy assessments of a new integrated system with different psychrometric processes for HVAC&R applications. The mass, energy, entropy and exergy balance equations for all system components and processes are developed for analysis and performance assessment purposes. In addition, a novel integrated system with psychrometric processes is proposed and thermodynamically analysed. Both energy and exergy efficiencies for individual components, sub-processes and the integrated system under different conditions and capacities are defined and determined. Parametric studies are conducted by varying dead state properties and operating conditions to investigate their effects on the system performance. The results show that the energy and exergy efficiencies of the integrated system become 18.6% and 33.31% respectively. (C) 2014 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:159 / 167
页数:9
相关论文
共 50 条
  • [1] New frontiers for HVAC&R
    Bullard, C. W.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 34 - 42
  • [2] CFD applications in the HVAC&R industry
    Ladeinde, F
    Nearon, MD
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1997, 39 (01): : 44 - 48
  • [3] CFD applications in the HVAC&R industry
    Ladeinde, Foluso
    Nearon, Michelle D.
    ASHRAE Journal, 1997, 39 (01):
  • [4] Exergy analysis of psychrometric processes for HVAC&R applications
    Kanoglu, Mehmet
    Dincer, Ibrahim
    Rosen, Marc A.
    ASHRAE TRANSACTIONS 2007 VOL 113, PT 2, 2007, 113 : 172 - 180
  • [5] Common Data Definitions for HVAC&R Industry Applications
    Glazer, Jason
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 2, 2009, 115 : 531 - 544
  • [6] A review on polymer heat exchangers for HVAC&R applications
    T'Joen, C.
    Park, Y.
    Wang, Q.
    Sommers, A.
    Han, X.
    Jacobi, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (05): : 763 - 779
  • [7] Performance assessment of integrated energy systems for HVAC applications
    Al Ali, M.
    Dincer, I.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2016, 13 (13) : 1342 - 1351
  • [8] Characterising the energy performance of centralised HVAC&R systems in the UK
    Shahrestani, Mehdi
    Yao, Runming
    Cook, Geoffrey K.
    ENERGY AND BUILDINGS, 2013, 62 : 239 - 247
  • [9] Measurement and Control System of HVAC&R Integration Testing Platform
    Zhang, Kai
    Zhang, Xiaosong
    Li, Shuhong
    Wang, Geng
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 351 - 359
  • [10] China's New Normal Energy Efficiency in HVAC&R
    不详
    ASHRAE JOURNAL, 2015, 57 (07) : 5 - +