Flexural and torsional properties of a glass fiber-reinforced composite diaphyseal bone model with multidirectional fiber orientation

被引:6
|
作者
Dahl, Kalle A. [1 ]
Moritz, Niko [1 ,3 ]
Vallittu, Pekka K. [1 ,2 ]
机构
[1] Univ Turku, Dept Biomat Sci & Biocity, Turku Biomat Res Program, Inst Dent,TCBC, Itainen Pitkakatu 4 B,2nd Floor, FIN-20520 Turku, Finland
[2] City Turku Welf Div, Turku, Finland
[3] Turku Biomat Res Program, Biomed Engn Res Grp, Turku, Finland
关键词
Fiber-reinforced composite; Implant; Mechanical testing; Segmental bone defect; DONOR-SITE MORBIDITY; IMPLANTS; RECONSTRUCTION; DEFECTS; SURGERY; FEMUR;
D O I
10.1016/j.jmbbm.2018.07.027
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although widely used, metallic implants have certain drawbacks in reconstructive bone surgery. Their high stiffness in respect to cortical bone can lead to complications which include periprosthetic fractures and aseptic loosening. In contrast to metallic alloys, fiber-reinforced composites (FRC) composed of a thermoset polymer matrix reinforced with continuous E-glass fibers have elastic properties matching those of bone. We investigated the mechanical properties of straight FRC tubes and FRC bone models representing the diaphysis of rabbit femur prepared from glass fiber/bisphenol A glycidyl methacrylate (BisGMA) - triethylene glycol dimethacrylate (TEGDMA) composite in three-point bending and torsion. Three groups of straight FRC tubes with different fiber orientations were mechanically tested to determine the best design for the FRC bone model. Tube 1 consisted most axially oriented unidirectional fiber roving and fewest bidirectional fiber sleevings. Fiber composition of tube 3 was the opposite. Tube 2 had moderate composition of both fiber types. Tube 2 resisted highest stresses in the mechanical tests and its fiber composition was selected for the FRC bone model. FRC bone model specimens were then prepared and the mechanical properties were compared with those of cadaver rabbit femora. In three-point bending, FRC bone models resisted 39-54% higher maximum load than rabbit femora with similar flexural stiffness. In torsion, FRC bone models resisted 31% higher maximum torque (p < 0.001) and were 38% more rigid (p = 0.001) than rabbit femora. Glass fiber-reinforced composites have good biocompatibility and from a biomechanical perspective, they could be used even in reconstruction of segmental diaphyseal defects. Development of an implant applicable for clinical use requires further studies.
引用
收藏
页码:143 / 147
页数:5
相关论文
共 50 条
  • [41] CRACK FIBER INTERACTION IN SIC FIBER-REINFORCED GLASS MATRIX COMPOSITE
    SEKINE, K
    KAGAWA, Y
    NIPPON SERAMIKKUSU KYOKAI GAKUJUTSU RONBUNSHI-JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 1992, 100 (04): : 621 - 624
  • [42] The evaluation of the mechanical properties of glass, kenaf, and honeycomb fiber-reinforced composite
    Abidin, Nur Marini Zainal
    Sultan, Mohamed Thariq Hameed
    Shah, Ain Umaira Md
    Shahar, Farah Syazwani
    Najeeb, Muhammad Imran
    Ali, Mohd Radzi
    Basri, Adi Azriff
    Baloor, Satish Shenoy
    Gaff, Milan
    Hui, David
    REVIEWS ON ADVANCED MATERIALS SCIENCE, 2023, 62 (01)
  • [43] MICROSTRUCTURE AND PROPERTIES OF SIC FIBER-REINFORCED GLASS-CERAMIC COMPOSITE
    ZHU, PN
    GUO, JK
    YANG, HM
    ZHANG, YF
    HUANG, SZ
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1993, 12 (08) : 526 - 529
  • [44] The effect of high fiber fraction on some mechanical properties of unidirectional glass fiber-reinforced composite
    Abdulmajeed, Aous A.
    Narhi, Timo O.
    Vallittu, Pekka K.
    Lassila, Lippo V.
    DENTAL MATERIALS, 2011, 27 (04) : 313 - 321
  • [45] Bone tissue responses to glass fiber-reinforced composite implants - a histomorphometric study
    Ballo, A. M.
    Akca, E. A.
    Ozen, T.
    Lassila, L.
    Vallittu, P. K.
    Narhi, T. O.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (06) : 608 - 615
  • [46] Flexural Behavior of Fiber-Reinforced SCC for Monolithic and Composite Beams
    Kassimi, Fodhil
    El-Sayed, Ahmed Kamal
    Khayat, Kamal Henri
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2021, 19 (08) : 937 - 949
  • [47] Effect of fiber content on flexural properties of glass fiber-reinforced polyamide-6 prepared by injection molding
    Nagakura, Manamu
    Tanimoto, Yasuhiro
    Nishiyama, Norihiro
    DENTAL MATERIALS JOURNAL, 2017, 36 (04) : 415 - 421
  • [48] Acoustic emission analysis of fiber-reinforced composite in flexural testing
    Alander, P
    Lassila, LVJ
    Tezvergil, A
    Vallittu, PK
    DENTAL MATERIALS, 2004, 20 (04) : 305 - 312
  • [49] Effect of short glass fiber/filler particle proportion on flexural and diametral tensile strength of a novel fiber-reinforced composite
    Fonseca, Rodrigo Borges
    de Almeida, Leticia Nunes
    Martins Mendes, Gustavo Adolfo
    Barbosa Kasuya, Amanda Vessoni
    Favarao, Isabella Negro
    de Paula, Marcella Silva
    JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (01) : 47 - 53
  • [50] Evaluation of flexural properties and dynamic mechanical analysis of glass fiber-reinforced polyamide resin
    Unver, Senem
    Yildirim, Arzu Zeynep
    EUROPEAN ORAL RESEARCH, 2021, 55 (03) : 116 - 123