Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation

被引:61
|
作者
Zderic, Ivan [1 ]
Stoffel, Karl [2 ,3 ]
Sommer, Christoph [4 ]
Hoentzsch, Dankward [5 ]
Gueorguiev, Boyko [1 ]
机构
[1] AO Res Inst Davos, Clavadelerstr 8, CH-7270 Davos, Switzerland
[2] Cantonal Hosp Baselland, Bruderholz, Switzerland
[3] Univ Basel, Basel, Switzerland
[4] Cantonal Hosp Graubuenden, Chur, Switzerland
[5] BG Klin Tubingen, Tubingen, Germany
关键词
Transverse patella fracture; Tension band wiring; Kirschner wire; Cannulated screw; Biomechanics; Interfragmentary pressure; OLECRANON FRACTURES; OSTEOSYNTHESIS;
D O I
10.1016/j.injury.2017.05.037
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: The aim of this study was to investigate the validity of the dynamic compression principle of tension band wiring in two techniques for patella fracture treatment. Methods: Twelve human cadaveric knees with simulated transverse patella fractures were assigned to two groups for treatment with tension band wiring using either Kirschner (K-) wires or cannulated screws. Biomechanical testing was performed over three knee movement cycles between 90 degrees flexion and 0 degrees full extension. Pressure distribution in the fracture gap and fracture site displacement were evaluated at the 3rd cycle in 15 degrees steps, namely 90 degrees -75 degrees -60 degrees -45 degrees -30 degrees -15 degrees -0 degrees extension phase and 0 degrees -15 degrees -30 degrees -45 degrees 60 degrees -75 degrees -90 degrees flexion phase. Results: Mean anterior / posterior interfragmentary pressure in the groups with K-wires and cannulated screws ranged within 0.16-0.40 MPa / 0.12-0.35 MPa and 0.37-0.59 MPa / 0.10-0.30 MPa, respectively. These changes remained non-significant for both groups and loading phases (P >= 0.171). Mean anterior / posterior fracture site displacement for K-wires and cannulated screws ranged within -0.01-0.53 mm / 0.11-0.74 mm and 0.11-0.55 mm / -0.10-0.50 mm, respectively. Anterior displacement remained without significant changes for both groups and loading phases (P >= 0.112). However, posterior displacement underwent a significant increase in the course of knee extension for K-wires (P <= 0.047), but not for cannulated screws (P >= 0.202). Significantly smaller displacement at the posterior fracture site was detected in the group with cannulated screws compared to K-wires at 60 degrees and 75 degrees extension phase (P <= 0.017), as well as at 45 degrees, 60 degrees and 75 degrees flexion phase (P <= 0.018). The critical value of 2 mm displacement at the posterior fracture site was not reached for any specimen and fixation technique. Knee extension was accompanied by synchronous increase in quadriceps pulling force. Conclusions: Tension band wiring fulfills from a biomechanical perspective the requirements for sufficient stability of transverse patella fracture fixation. It should, however, rather be considered as a static fixation principle than a dynamic one. Tension band wiring with cannulated screws was found advantageous over Kirschner wires in terms of interfragmentary movements at the posterior fracture site. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1749 / 1757
页数:9
相关论文
共 50 条
  • [1] Biomechanical comparison of a novel tensioned cable construct versus tension band wiring for transverse patella fracture fixation
    Benjamin D. Kagan
    Alec D. Sundet
    Mack Gardner-Morse
    Pirapon L. Chaidarun
    Bruce D. Beynnon
    Patrick C. Schottel
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 1573 - 1580
  • [2] Biomechanical comparison of a novel tensioned cable construct versus tension band wiring for transverse patella fracture fixation
    Kagan, Benjamin D.
    Sundet, Alec D.
    Gardner-Morse, Mack
    Chaidarun, Pirapon L.
    Beynnon, Bruce D.
    Schottel, Patrick C.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (05): : 1573 - 1580
  • [3] Biomechanical comparison of three tension band wiring techniques for transverse fracture of patella: Kirschner wires, cannulated screws, and ring pins
    Lee, Kyung-Hag
    Lee, Yohan
    Lee, Young Ho
    Cho, Bong Wan
    Kim, Min Bom
    Baek, Goo Hyun
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (03)
  • [4] Biomechanical Evaluation of Transverse Patella Fracture Fixation Using Headless Screws: A Comparison of Suture Versus Cable as a Tension Band
    Bric, Justin D.
    Martin, Jill M.
    McGrady, Linda M.
    Wang, Mei
    Schmeling, Gregory J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (06) : E253 - E257
  • [5] A comparison of EFECE systems with tension band wiring for patella fracture fixation in cadavers
    Karadeniz, Emre
    Keskinoz, Elif Nedret
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [6] Biomechanical comparison of a new staple technique with tension band wiring for transverse patella fractures
    Schnabel, Bernd
    Scharf, Martin
    Schwieger, Karsten
    Windolf, Markus
    van der Pol, Bas
    Braunstein, Volker
    Appelt, Andreas
    CLINICAL BIOMECHANICS, 2009, 24 (10) : 855 - 859
  • [7] A comparison of EFECE systems with tension band wiring for patella fracture fixation in cadavers
    Emre Karadeniz
    Elif Nedret Keskinoz
    Journal of Orthopaedic Surgery and Research, 15
  • [8] Biomechanical comparison for different configurations of tension band wiring techniques in treating an olecranon fracture
    Wu, CC
    Tai, CL
    Shih, CH
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 48 (06): : 1063 - 1067
  • [9] Biomechanical Comparison of Tension Band Fixation of Patella Transverse Fracture: Headless Screws Versus Headed Screws
    Martin, Jill M.
    Applin, Dylan T.
    McGrady, Linda M.
    Wang, Mei
    Schmeling, Gregory J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (06) : E240 - E245
  • [10] Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella
    Ali, Mohammed
    Kuiper, Jan
    John, Joby
    CHINESE JOURNAL OF TRAUMATOLOGY, 2016, 19 (05) : 255 - 258