Ultrasonography and Fine-Needle Aspiration in Indeterminate Thyroid Nodules: A Systematic Review of Diagnostic Test Accuracy

被引:13
|
作者
Staibano, Phillip [1 ,2 ]
Forner, David [3 ,4 ]
Noel, Christopher W. [1 ,2 ,4 ]
Zhang, Han [5 ]
Gupta, Michael [5 ]
Monteiro, Eric [6 ]
Sawka, Anna M. [7 ,8 ]
Pasternak, Jesse D. [2 ,9 ,10 ]
Goldstein, David P. [1 ,2 ]
de Almeida, John R. [1 ,2 ,4 ]
机构
[1] Univ Hlth Network, Dept Otolaryngol Head & Neck Surg, Toronto, ON, Canada
[2] Univ Toronto, Toronto, ON, Canada
[3] Dalhousie Univ, Div Otolaryngol Head & Neck Surg, Halifax, NS, Canada
[4] Univ Toronto, Inst Hlth Policy Management & Evaluat, Toronto, ON, Canada
[5] McMaster Univ, Dept Otolaryngol Head & Neck Surg, Hamilton, ON, Canada
[6] Univ Toronto, Dept Otolaryngol Head & Neck Surg, Div Rhinol, Toronto, ON, Canada
[7] Univ Toronto, Dept Med, Div Endocrinol, Toronto, ON, Canada
[8] Univ Hlth Network, Dept Med, Div Endocrinol, Toronto, ON, Canada
[9] Univ Toronto, Dept Surg, Toronto, ON, Canada
[10] Univ Hlth Network, Toronto Gen Hosp, Res Inst, Toronto, ON, Canada
来源
LARYNGOSCOPE | 2022年 / 132卷 / 01期
关键词
Thyroid cancer; ultrasonography; fine-needle aspiration biopsy; meta-analysis; thyroid nodules; systematic review; UNDETERMINED SIGNIFICANCE/FOLLICULAR LESION; BETHESDA CATEGORY; RISK STRATIFICATION; SONOGRAPHIC FEATURES; WHITE PAPER; US FEATURES; MALIGNANCY; CANCER; METAANALYSIS; ATYPIA;
D O I
10.1002/lary.29778
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis Sonographic risk criteria may assist in further prognostication of indeterminate thyroid nodules (ITNs). Our aim was to determine whether sonographic criteria could further delineate the post-test probability of malignancy in ITNs. Study Design Meta-analysis of diagnostic test accuracy. Methods A systematic review of Web of Science, MEDLINE, EMBASE, and CINAHL was performed from inception to April 15, 2021. Eligible studies included those which reported ultrasonographic evaluations with the American Thyroid Association (ATA) or the Thyroid Imaging Reporting and Data System (TIRADS) in adult patients with ITNs. ATA or TIRADS were scored as low (negative) or high (positive) malignancy risk using a previously validated binary classification. Primary outcomes included pooled sensitivity, specificity, likelihood ratios, and diagnostic odds ratio for all sonographic criteria. Studies were appraised using Quality Assessment of Diagnostic Accuracy Studies and the data were pooled using bivariate random-effects models. Results Seventeen studies were included in the analysis. For Bethesda III, ATA had a specificity (0.90, 95% confidence interval (CI): 0.74-0.94), but a sensitivity of 0.52 (95% CI: 0.25-0.77). Conversely, K-TIRADS had the highest sensitivity (0.78, 95% CI: 0.62-0.89) with a specificity of 0.53 (95% CI: 0.31-0.74). Furthermore, American College of Radiology and EU TIRADS had specificities of 0.60 (95% CI: 0.36-0.80) and 0.81 (95% CI: 0.73-0.87) with sensitivities of 0.70 (95% CI: 0.37-0.90) and 0.38 (95% CI: 0.20-0.60), respectively. There were few studies with Bethesda IV nodules. Conclusions Though dependent on malignancy rates, Bethesda III nodules with low-suspicion TIRADS features may benefit from clinical observation, whereas nodules with high-suspicion ATA features may require molecular testing and/or surgery. Level of Evidence NA Laryngoscope, 2021
引用
下载
收藏
页码:242 / 251
页数:10
相关论文
共 50 条
  • [41] Factors affecting the false negativity of fine-needle aspiration biopsy in thyroid nodules with indeterminate cytology
    Ozemir, Ibrahim Ali
    CUKUROVA MEDICAL JOURNAL, 2023, 48 (02): : 499 - 512
  • [42] FINE-NEEDLE ASPIRATION BIOPSY OF THYROID-NODULES
    RUBENFELD, S
    WHEELER, TM
    SPJUT, HJ
    TEXAS MEDICINE, 1982, 78 (09) : 41 - 44
  • [43] FINE-NEEDLE ASPIRATION (FNA) OF THYROID COLD NODULES
    GAHAM, N
    ROCMANS, P
    KETELBANTBALASSE, P
    VERELST, J
    MOCKEL, J
    GLINOER, D
    ANNALES D ENDOCRINOLOGIE, 1981, 42 (06) : 543 - 544
  • [44] Fine-needle aspiration cytology of solitary thyroid nodules
    Ersöz, C
    Firat, P
    Uguz, A
    Kuzey, GM
    CANCER CYTOPATHOLOGY, 2004, 102 (05) : 302 - 307
  • [45] Fine-needle Aspiration of Thyroid Nodules: Is it Worth Repeating?
    Fernandes, Vera
    Pereira, Tania
    Eloy, Catarina
    ACTA MEDICA PORTUGUESA, 2017, 30 (06) : 472 - 478
  • [46] Role of fine-needle aspiration in the management of thyroid nodules
    Mofid, Ali R.
    Yazdani, Tahereh
    Shahrzad, Maryam
    SeyedAlinaghi, SeyedAhmad
    Zandieh, Saeed
    SAUDI MEDICAL JOURNAL, 2009, 30 (04) : 515 - 518
  • [47] Fine-needle aspiration biopsy in the management of thyroid nodules
    Rizvi, AA
    Selgrath, C
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 110 (03) : 407 - 408
  • [48] Fine-needle aspiration biopsy versus ultrasoundguided fine-needle aspiration biopsy: Costeffectiveness as a frontline diagnostic modality for solitary thyroid nodules
    Khalid, Ayesha N.
    Quraishi, Sadeq A.
    Hollenbeak, Christopher S.
    Stack, Brendan C., Jr.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2008, 30 (08): : 1035 - 1039
  • [49] PEDIATRIC THYROID-NODULES - DIAGNOSTIC-ACCURACY AND DISEASE DEMOGRAPHICS AS DETERMINED BY FINE-NEEDLE ASPIRATION BIOPSY
    RAAB, SS
    SILVERMAN, JF
    ELSHEIKH, TM
    WAKELY, P
    LABORATORY INVESTIGATION, 1994, 70 (01) : A147 - A147
  • [50] DIAGNOSTIC-ACCURACY OF FINE-NEEDLE ASPIRATION BIOPSY VERSUS FROZEN SECTION IN SOLITARY THYROID-NODULES
    BUGIS, SP
    YOUNG, JEM
    ARCHIBALD, SD
    CHEN, VSM
    AMERICAN JOURNAL OF SURGERY, 1986, 152 (04): : 411 - 416