Endovascular embolization of 150 basilar tip aneurysms with Guglielmi detachable coils: results of the Food and Drug Administration multicenter clinical trial

被引:202
|
作者
Eskridge, JM
Song, JK
机构
[1] Univ Washington, Dept Neurol Surg, Seattle, WA 98195 USA
[2] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
basilar artery; embolization; Guglielmi detachable coil; intracranial aneurysm;
D O I
10.3171/jns.1998.89.1.0081
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. To assess the safety and efficacy of aneurysm embolization performed using Guglielmi detachable coils (GDCs), the authors reviewed the results of a cohort of 150 patients with either ruptured (83 patients) or unruptured (67 patients) basilar tip aneurysms treated with these detachable platinum coil devices in the early part of the United States multicenter GDC clinical trial that led to Food and Drug Administration approval for the device. Methods. The most common presentation in this cohort of patients was headache (53%). All patients were entered into the trial after neurosurgical assessment excluded them as candidates for surgical clipping of their aneurysms. Greater than 90% coil packing was achieved in 75% of the patients. For those patients in whom follow-up information was available, the mean angiographic and clinical e:valuation follow-up time for 61 patients with ruptured aneurysms was 13.7 months (range 0-43 months) and that for the 49 patients with unruptured aneurysms was 9.8 (range 0-40 months). Conservative mortality rates included up to 23% for the ruptured aneurysm group and up to 12% for the unruptured aneurysm group; the rebleeding rate for treated ruptured aneurysms was up to 3.3% and the bleeding rate for unruptured aneurysms up to 4.1%. Permanent deficits due to stroke in patients with ruptured or unruptured aneurysms occurred in up to 5% and 9%, respectively. Vasospasm occurred in 8% of the patients; it was associated with two deaths. Periprocedural mortality was 2.7% (four patients with ruptured aneurysms). Conclusions. Detachable platinum coil embolization is a promising treatment for ruptured basilar tip aneurysms that are not surgically clippable: in selected patients it offers lower incidences of morbidity and mortality compared with conservative medical management. The role of this procedure in unruptured basilar tip aneurysms is unclear with less supportive results. More long-term follow-up evaluation is necessary and results are expected to improve.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [41] Evaluation of the EVO/EVO+ Sphere and Toric Visian ICL: Six Month Results from the United States Food and Drug Administration Clinical Trial
    Packer, Mark
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1541 - 1553
  • [43] Results of the U. S. Food and Drug Administration Continued Access Clinical Trial of the GORE HELEX Septal Occluder for Secundum Atrial Septal Defect
    Javois, Alexander J.
    Rome, Jonathan J.
    Jones, Thomas K.
    Zahn, Evan M.
    Fleishman, Craig E.
    Pignatelli, Ricardo H.
    Latson, Larry A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (08) : 905 - 912
  • [44] A Multicenter Study to Evaluate the Safety and Efficacy of a Stand-Alone Anterior Carbon I/F Cage for Anterior Lumbar Interbody Fusion Two-Year Results From a Food and Drug Administration Investigational Device Exemption Clinical Trial
    Li, Jingfeng
    Dumonski, Mark L.
    Liu, Qinyi
    Lipman, Adam
    Hong, Joseph
    Yang, Nuo
    Jin, Zhengshuai
    Ren, Yongxin
    Limthongkul, Worawat
    Bessey, Jason T.
    Thalgott, John
    Gebauer, Greg
    Albert, Todd J.
    Vaccaro, Alexander R.
    SPINE, 2010, 35 (26) : E1564 - E1570
  • [45] Reduced anticoagulation after mechanical aortic valve replacement: Interim results from the Prospective Randomized On-X Valve Anticoagulation Clinical Trial randomized Food and Drug Administration investigational device exemption trial
    Puskas, John
    Gerdisch, Marc
    Nichols, Dennis
    Quinn, Reed
    Anderson, Charles
    Rhenman, Birger
    Fermin, Lilibeth
    McGrath, Michael
    Kong, Bobby
    Hughes, Chad
    Sethi, Gulshan
    Wait, Michael
    Martin, Tomas
    Graeve, Allen
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (04): : 1202 - 1210
  • [46] Validation of the STA-Liatest DDi assay for exclusion of proximal deep vein thrombosis according to the latest Clinical and Laboratory Standards Institute/Food and Drug Administration guideline: results of a multicenter management study
    Aguilar, Carlos
    Sartori, Michelangelo
    D'Angelo, Armando
    Kabrhel, Christopher
    Groce, James
    de Maistre, Emmanuel
    Wasan, Suman M.
    Kassis, Jeannine
    Lazarchick, John
    Kaide, Colin
    Vera, Pascual Marco
    Kline, Jeffrey
    Courtney, D. Mark
    Rubin, Andrew
    Sharafuddin, Melhem
    Pernod, Gilles
    BLOOD COAGULATION & FIBRINOLYSIS, 2018, 29 (06) : 562 - 566
  • [47] Validation of STA-Liatest D-Di assay for exclusion of pulmonary embolism according to the latest Clinical and Laboratory Standard Institute/Food and Drug Administration guideline. Results of a multicenter management study
    Pernod, Gilles
    Wu, Haifeng
    de Maistre, Emmanuel
    Lazarchick, John
    Kassise, Jeannine
    Aguilar, Carlos
    Vera, Pascual M.
    Palareti, Gualtiero
    D'Angelo, Armando
    BLOOD COAGULATION & FIBRINOLYSIS, 2017, 28 (03) : 254 - 260
  • [48] Decompression and Coflex Interlaminar Stabilization Compared With Decompression and Instrumented Spinal Fusion for Spinal Stenosis and Low-Grade Degenerative Spondylolisthesis Two-Year Results From the Prospective, Randomized, Multicenter, Food and Drug Administration Investigational Device Exemption Trial
    Davis, Reginald J.
    Errico, Thomas J.
    Bae, Hyun
    Auerbach, Joshua D.
    SPINE, 2013, 38 (18) : 1529 - 1539
  • [49] Five-year results of the prospective, randomized, multicenter, Food and Drug Administration investigational device exemption study of the ProDisc-L total disc replacement versus circumferential arthrodesis for the treatment of single-level degenerative disc disease Clinical article
    Zigler, Jack E.
    Delamarter, Rick B.
    JOURNAL OF NEUROSURGERY-SPINE, 2012, 17 (06) : 493 - 501
  • [50] Lumbar interbody fusion using the Brantigan I/F Cage for posterior lumbar interbody fusion and the variable pedicle screw placement system - Two-year results from a Food and Drug Administration Investigational Device Exemption Clinical Trial
    Brantigan, JW
    Steffee, AD
    Lewis, ML
    Quinn, LM
    Persenaire, JM
    SPINE, 2000, 25 (11) : 1437 - 1446