Flexible CMUT for Vibrating Mesh Nebulize

被引:0
|
作者
Certon, Dominique [1 ]
Barcella, Flavien [1 ]
Ben Messaoud, Jaweb [1 ]
Ladroue, Julien [2 ]
Vecellio, Laurent [3 ]
Heuze-Vourc'h, Nathalie [3 ]
Alquier, Daniel [1 ]
机构
[1] Univ Tours, GREMAN UMR CNRS 7347, INSA Ctr Val Loire, 16 Rue Pierre & Marie Curie,BP 7155, F-37071 Tours 2, France
[2] STMicroelectronics, Rue Thales Milet, Tours, France
[3] Univ Tours, INSERM, UMR 1100, Ctr Etude Pathol Respiratoires, Tours, France
关键词
capacitive micromachined ultrasonic transducers; drug delivery;
D O I
10.1109/ultsym.2019.8926308
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work is a feasibility study aiming to demonstrate that CMUT technology could be used as an actuator source for vibrating mesh nebulizer. Ring shape PZT materials are commonly used in commercial products but they suffer from technological limitations (for example significant self-heating) that could be overcome by CMUT technology. This paper shows experimental results obtained from a first prototype realized with a linear array. A thin disk membrane was locally etched below few elements, on the rear face of the Si substrate. It is demonstrated that the excitation of the CMUT elements, at low frequencies (in the kHz frequency range), enables the thin membrane actuation, in air and in water. Significant displacement (approximate to 1 mu m) were observed for the first and the second resonance mode of the membrane
引用
收藏
页码:742 / 745
页数:4
相关论文
共 50 条
  • [1] Reliability of Vibrating Mesh Technology
    Gowda, Ashwin A.
    Cuccia, Ann D.
    Smaldone, Gerald C.
    RESPIRATORY CARE, 2017, 62 (01) : 65 - 69
  • [2] Flexible transparent CMUT arrays for photoacoustic tomography
    Ghavami, Mahyar
    Ilkhechi, Afshin Kashani
    Zemp, Roger
    OPTICS EXPRESS, 2022, 30 (10) : 15877 - 15894
  • [3] CHARACTERIZATION OF VIBRATING MESH AEROSOL GENERATORS
    Huang, S. H.
    Chan, W. H.
    Lin, C. W.
    Wu, H. D.
    Chen, C. C.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (02) : A21 - A21
  • [4] Characterization of Vibrating Mesh Aerosol Generators
    Kuo, Yu-Mei
    Chan, Wei-Hsiang
    Lin, Chih-Wei
    Huang, Sheng-Hsiu
    Chen, Chih-Chieh
    AEROSOL AND AIR QUALITY RESEARCH, 2019, 19 (08) : 1678 - 1687
  • [5] IDENTIFICATION OF VIBRATING FLEXIBLE STRUCTURES
    RAJARAM, S
    JUNKINS, JL
    JOURNAL OF GUIDANCE CONTROL AND DYNAMICS, 1985, 8 (04) : 463 - 470
  • [6] Vibration analysis of MEMS vibrating mesh atomizer
    Sharma, Pallavi
    Jackson, Nathan
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2022, 32 (06)
  • [7] Use of a vibrating mesh nebulizer for allergen challenge
    Cockcroft, Donald W.
    Davis, Beth E.
    Blais, Christianne M.
    Boulet, Louis-Philippe
    Boulay, Marie-Eve
    Villeneuve, Helene
    Gauvreau, Gail M.
    O'Byrne, Paul M.
    Howie, Karen J.
    Obminski, Caitlin D.
    ALLERGY ASTHMA AND CLINICAL IMMUNOLOGY, 2019, 15 (01):
  • [8] Use of a vibrating mesh nebulizer for allergen challenge
    Donald W. Cockcroft
    Beth E. Davis
    Christianne M. Blais
    Louis-Philippe Boulet
    Marie-Éve Boulay
    Hélène Villeneuve
    Gail M. Gauvreau
    Paul M. O’Byrne
    Karen J. Howie
    Caitlin D. Obminski
    Allergy, Asthma & Clinical Immunology, 15
  • [9] A cost and environmental analysis of a vibrating mesh nebuliser
    Dymond, Amy
    Afonso, Daniela
    Mealing, Stuart
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [10] A flexible algorithm for layout-optimized sparse cMUT arrays
    Austeng, A
    Kirkebo, JE
    Holm, S
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 1266 - 1269