State-of-the-Art in Synchrophasor Measurement Technology Applications in Distribution Networks and Microgrids

被引:6
|
作者
Aminifar, Farrokh [1 ,2 ]
Rahmatian, Farnoosh [3 ]
Shahidehpour, Mohammad [1 ]
机构
[1] IIT, Robert W Galvin Ctr Elect Innovat, Chicago, IL 60616 USA
[2] Univ Tehran, Sch Elect & Comp Engn, Coll Engn, Tehran 113654563, Iran
[3] NuGrid Power Corp, Vancouver, BC V3N 4V1, Canada
关键词
State estimation; Phasor measurement units; Power measurement; Monitoring; Microgrids; Distribution networks; Power system stability; Synchrophasor measurement technology (SMT); distribution-level phasor measurement unit (DPMU); active distribution networks (ADNs); FAULTED LINE IDENTIFICATION; RELIABILITY-CENTERED MAINTENANCE; AUTO-RECLOSING SCHEME; OPTIMAL PMU PLACEMENT; DISTRIBUTION-SYSTEM; COMPREHENSIVE SCHEME; FREQUENCY CONTROL; MODEL SYNTHESIS; VOLTAGE; PROTECTION;
D O I
10.1109/ACCESS.2021.3127915
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Although synchrophasor measurement technology (SMT) has become a somewhat mature and operational tool used in transmission-level power networks, its use in active distribution networks (ADNs) is still in very early stages. Due to distinct features (such as unbalanced operation, very low phase angle differences, greater harmonics pollution, and lower signal-to-noise ratios in distribution networks), transmission-level devices and applications may not be fully effective at the distribution level. Extensive research and development efforts are in progress to bring distribution-level phasor measurement units (DPMUs) to an operational stage in ADNs. This essential work is made even more urgent by changing ADNs that are widely integrating distributed energy resources and enabling demand-side entities as active network players, in some cases considering authorizing them for peer-to-peer energy trading. This paper focuses on SMT/DPMU applications in ADNs and microgrids. We specifically elaborate on how SMT/DPMUs are enabling 1) effective situational awareness, 2) enhanced protection and fault location functions, 3) novel control algorithms and augmented energy management applications, and 4) long-term baselining and analysis. Various barriers and challenges that come with rapid and broad deployment of SMT/DPMUs and their associated applications are also discussed.
引用
收藏
页码:153875 / 153892
页数:18
相关论文
共 50 条
  • [41] A state-of-the-art report: Markets & technology
    Callari, JJ
    [J]. PLASTICS WORLD, 1996, 54 (09): : 36 - 40
  • [42] UNDERSEA CABLES - A STATE-OF-THE-ART TECHNOLOGY
    REINAUDO, C
    [J]. ELECTRICAL COMMUNICATION, 1994, (01): : 5 - 10
  • [43] Metrology requirements of state-of-the-art protection schemes for DC microgrids
    Li, Chunpeng
    Rakhra, Puran
    Norman, Patrick
    Burt, Graeme
    Clarkson, Paul
    [J]. JOURNAL OF ENGINEERING-JOE, 2018, (15): : 987 - 992
  • [44] COATER MEASUREMENT AND CONTROL - STATE-OF-THE-ART
    SHAPIRO, SI
    [J]. PULP & PAPER-CANADA, 1987, 88 (08) : 76 - 79
  • [45] Blood volume measurement - state-of-the-art
    Orth, VH
    Rehm, M
    Haller, M
    Thiel, M
    Finsterer, U
    [J]. ANAESTHESIST, 2001, 50 (08): : 562 - 568
  • [46] State-of-the-Art stock consistency measurement
    不详
    [J]. WOCHENBLATT FUR PAPIERFABRIKATION, 2005, 133 (20): : 1256 - 1256
  • [47] State-of-the-art review on energy management and control of networked microgrids
    Singh, Arvind R.
    Raju, D. Koteswara
    Raghav, L. Phani
    Kumar, R. Seshu
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2023, 57
  • [48] The state-of-the-art in performance measurement in Spain
    Heras, Miguel
    [J]. MEASURING BUSINESS EXCELLENCE, 2005, 9 (03) : 205 - 210
  • [49] NETWORKS FOR IMAGE COMMUNICATION - STATE-OF-THE-ART
    MEYEREBRECHT, D
    [J]. RADIOLOGE, 1994, 34 (06): : 309 - 316
  • [50] State-of-the-Art Duolingo Features and Applications
    Savvani, Stamatia
    [J]. CHALLENGES OF THE DIGITAL TRANSFORMATION IN EDUCATION, ICL2018, VOL 2, 2019, 917 : 139 - 148