A Hysteresis Current Control based Shunt Current Compensation Scheme for Power Quality Improvement in High Power Radiology Applications

被引:0
|
作者
Angadi, Shridevi. R. [1 ]
Nanjundaswamy, R. [2 ]
Srinivas, N. R. [3 ]
Murthy, R. S. Ananda [1 ]
机构
[1] SJCE, Dept EEE, Mysore, Karnataka, India
[2] SIT, Dept EEE, Tumkur, Karnataka, India
[3] Skanray Technol, Mysore, Karnataka, India
关键词
Hysteresis Current Control; Active Power Filter; THD reduction;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, a shunt active power filter scheme is proposed for a three phase system feeding a non-linear load. The system represents the HV generator used in high power radiology equipment. Hysteresis current control is used, which controls the operation such that a sinusoidal current is drawn from the source. The proposed method also reduces the THD, thus improving the power quality. The compensating currents are injected in phase opposition at the point of common contact to cancel out the harmonic currents in ac lines. The Hysteresis current control is used because it is simple and easy to implement. The simulation is carried out using MATLAB-SIMULINK software, whose results are displayed.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [31] An adaptive hysteresis band current controlled shunt active power filter
    Jog, Amruta N.
    Apte, Narayan G.
    2007 COMPATIBILITY IN POWER ELECTRONICS, 2007, : 163 - 167
  • [32] An adaptive hysteresis band current controller for shunt active power filter
    Kale, M
    Ozdemir, E
    ELECTRIC POWER SYSTEMS RESEARCH, 2005, 73 (02) : 113 - 119
  • [33] Improving the Efficiency of the Shunt Active Power Filter Acting with the Use of the Hysteresis Current Control Technique
    Szromba, Andrzej
    ENERGIES, 2023, 16 (10)
  • [34] Instantaneous power-based current control scheme for VAR compensation in hybrid AC/DC networks for smart grid applications
    Shanthi, Pandurangan
    Govindarajan, Uma
    Parvathyshankar, Deivasundari
    IET POWER ELECTRONICS, 2014, 7 (05) : 1216 - 1226
  • [35] Modified double hysteresis current control method for unified power quality controller
    Cheng, Qi-Ming
    Wang, Ying-Fei
    Cheng, Yin-Man
    Wu, Kai
    Bai, Yuan-Fei
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (04): : 713 - 730
  • [36] Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
    Bielecka, Agata
    Wojciechowski, Daniel
    SCIENTIFIC JOURNALS OF THE MARITIME UNIVERSITY OF SZCZECIN-ZESZYTY NAUKOWE AKADEMII MORSKIEJ W SZCZECINIE, 2020, 61 (133): : 9 - 16
  • [37] Current sensors and power switches fault detection and compensation for shunt active power filters
    Karimi, S.
    Poure, P.
    Saadate, S.
    Ghohpour, E.
    2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 3157 - 3161
  • [38] A novel power factor control scheme for high power GTO current source converter
    Xiao, Y
    Wu, B
    Rizzo, S
    Sotudeh, R
    IAS '96 - CONFERENCE RECORD OF THE 1996 IEEE INDUSTRY APPLICATIONS CONFERENCE, THIRTY-FIRST IAS ANNUAL MEETING, VOLS 1-4, 1996, : 865 - 869
  • [39] Study on shunt active power filter with high quality grid current waveform
    Qiu, Zhiling
    Zhao, Wenqiang
    Chen, Guozhu
    APEC 2008: TWENTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-4, 2008, : 933 - 938
  • [40] Hysteresis current control of hybrid active power filters
    Lam, C. -S.
    Wong, M. -C.
    Han, Y. -D.
    IET POWER ELECTRONICS, 2012, 5 (07) : 1175 - 1187