In this paper, a shunt active power filter scheme is proposed for a three phase system feeding a non-linear load. The system represents the HV generator used in high power radiology equipment. Hysteresis current control is used, which controls the operation such that a sinusoidal current is drawn from the source. The proposed method also reduces the THD, thus improving the power quality. The compensating currents are injected in phase opposition at the point of common contact to cancel out the harmonic currents in ac lines. The Hysteresis current control is used because it is simple and easy to implement. The simulation is carried out using MATLAB-SIMULINK software, whose results are displayed.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [1] A Vector Control based Shunt Current Compensation Scheme for Power Quality Improvement in High Power Radiology Applications
    Nanjundaswamy, R.
    Angadi, Shridevi. R.
    Srinivas, N. R.
    Vinayaka, K. U.
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON POWER AND ADVANCED CONTROL ENGINEERING (ICPACE), 2015, : 48 - 52
  • [2] Adaptive Hysteresis Current Control of Active Power Filters for Power Quality Improvement
    Bouzid, Allal El Moubarek
    Sicard, Pierre
    Cheriti, Ahmed
    Chaoui, Hicham
    Koumba, Paul Makanga
    2017 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2017, : 557 - 564
  • [3] Adaptive Hysteresis Current Controlled Shunt Active Power Filter for Power Quality Enhancement
    Thekkath, Preethi
    Prabha, S. U.
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2013), 2013, : 31 - 36
  • [5] Indirect current controlled shunt active power filter for power quality improvement
    Mahanty, R.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 : 441 - 449
  • [6] Fuzzy logic PWM current controller based shunt active power filter for power quality compensation
    Bayindir, K. Cagatay
    Tuemay, Mehmet
    Cuma, M. Ugras
    ENGINEERING INTELLIGENT SYSTEMS FOR ELECTRICAL ENGINEERING AND COMMUNICATIONS, 2008, 16 (01): : 5 - 16
  • [7] Power quality improvement with two compensation control strategies for Shunt Active Power Filter based on SMC
    Kaddari, Faiza
    Mazari, Benyounes
    Mihoub, Youcef
    Safa, Ahmed
    3RD INTERNATIONAL SYMPOSIUM ON ENVIRONMENTAL FRIENDLY ENERGIES AND APPLICATIONS (EFEA 2014), 2014,
  • [8] Double hysteresis current control strategy for shunt active power filter
    Electric Power College, South China University of Technology, Guangzhou 510640, China
    不详
    Dianli Xitong Baohu yu Kongzhi, 2009, 9 (60-64):
  • [9] Phase current estimation based shunt active power compensation
    Greber, Marton
    Fodor, Attila
    Magyar, Attila
    IFAC PAPERSONLINE, 2022, 55 (09): : 48 - 53
  • [10] Improved Quality of Compensation in Three-Level Shunt Active Power Filter Using Fractal Approach Based Current Hysteresis Controller
    Chauhan, Siddharthsingh K.
    Shah, M. T.
    Tekwani, P. N.
    IECON 2021 - 47TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2021,