Zero-crossing distortion in grid-connected PV inverters

被引:29
|
作者
Kotsopoulos, A
Heskes, PJM
Jansen, MJ
机构
[1] Tech Univ Eindhoven, Dept Elect Engn, NL-5600 MB Eindhoven, Netherlands
[2] Netherlands Energy Res Ctr, PV Syst Technol, NL-1755 ZG Petten, Netherlands
关键词
distortion; inverters; photovoltaic power systems; power system harmonics;
D O I
10.1109/TIE.2005.844254
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Zero-crossing distortion has been observed in the ac output current produced by some grid-connected photovoltaic inverters and this can cause a resonant response between the grid impedance and the inverter filter capacitor. In some cases, particularly with large numbers of parallel-connected inverters and with weak grids, the resonance can cause voltage distortion that may be large enough to disturb other nearby equipment. A number of commercially available inverters were tested to investigate the mechanisms of this distortion. A model was then developed to allow further simulations with different numbers of inverters and varying levels of distortion to be performed.
引用
收藏
页码:558 / 565
页数:8
相关论文
共 50 条
  • [21] Fault Current of PV Inverters Under Grid-Connected Operation: A Review
    Ricardo Fonseca Buzo
    Henrique Molina Barradas
    Fábio Bertequini Leão
    [J]. Journal of Control, Automation and Electrical Systems, 2021, 32 : 1053 - 1062
  • [22] Predictive Control Based on Analytic Model for PV Grid-connected Inverters
    Wu Jianhua
    Zhong Jing
    Li Longfei
    Tang Cong
    Yu Le
    [J]. PROCEEDINGS OF THE 2012 24TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2012, : 4295 - 4299
  • [23] Design Optimization of Transformerless Grid-Connected PV Inverters Including Reliability
    Koutroulis, Eftichios
    Blaabjerg, Frede
    [J]. 2012 TWENTY-SEVENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2012, : 1959 - 1966
  • [24] Adaptive control technique for suppression of resonance in grid-connected PV inverters
    Goh, Hongsoo
    Armstrong, Matthew
    Zahawi, Bashar
    [J]. IET POWER ELECTRONICS, 2019, 12 (06) : 1479 - 1486
  • [25] A Min-communication Control for Grid-connected Cascaded PV Inverters
    Liu, Hongyi
    Han, Hua
    Liu, Yao
    Su, Mei
    Hou, Xiaochao
    Zhang, Xin
    [J]. 2018 IEEE 4TH SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2018,
  • [26] Review on single-phase PV inverters for grid-connected applications
    Attanasio, R.
    Cacciato, M.
    Gennaro, F.
    Scarcella, G.
    [J]. NEW ASPECTS OF ENERGY, ENVIRONMENT, ECOSYSTEMS AND SUSTAINABLE DEVELOPMENT, PT 1, 2008, : 233 - +
  • [27] Fault Current of PV Inverters Under Grid-Connected Operation: A Review
    Buzo, Ricardo Fonseca
    Barradas, Henrique Molina
    Leao, Fabio Bertequini
    [J]. JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2021, 32 (04) : 1053 - 1062
  • [28] Power Loss Analysis for Single Phase Grid-Connected PV Inverters
    Nge, Chee Lim
    Midtgard, Ole-Morten
    Norum, Lars
    Saetre, Tor Oskar
    [J]. INTELEC 09 - 31ST INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, 2009, : 493 - +
  • [29] Design Optimization of Transformerless Grid-Connected PV Inverters Including Reliability
    Koutroulis, Eftichios
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (01) : 325 - 335
  • [30] Delta Power Control Strategy for Multistring Grid-Connected PV Inverters
    Sangwongwanich, Ariya
    Yang, Yongheng
    Blaabjerg, Frede
    Sera, Dezso
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (04) : 3862 - 3870