Determination of parabens in water samples by cloud point extraction and aqueous two-phase extraction using high-performance liquid chromatography

被引:14
|
作者
Noorashikin, M. S. [1 ]
Mohamad, S. [2 ]
Abas, M. R. [2 ]
机构
[1] Univ Malaysia Terengganu, Sch Marine Sci & Environm, Kuala Terengganu 21030, Malaysia
[2] Univ Malaya, Fac Sci, Dept Chem, Environm Res Grp, Kuala Lumpur 50603, Malaysia
关键词
Cloud point extraction; Aqueous two-phase extraction; Paraben; High-performance liquid chromatography; -cyclodextrin; Ionic liquid functionalized -cyclodextrin; IONIC LIQUID; NONIONIC SURFACTANT; BETA-CYCLODEXTRIN; POLYETHYLENE-GLYCOL; ORGANIC POLLUTANTS; SYSTEM; PRECONCENTRATION; SEPARATION; MODIFIER; REMOVAL;
D O I
10.1080/19443994.2015.1131749
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Five methods have been successfully developed which are the ionic liquid-two-phase extraction (IL-ATPS), ionic liquid-two-phase extraction with addition of -cyclodextrin as modifier (IL-CD-ATPS), cloud point extraction (CPE-DC193C), cloud point extraction with addition of -cyclodextrin as modifier (CPE-DC193C-CD), and cloud point extraction with addition of ionic liquid functionalized -cyclodextrin as modifier (CPE-DC193C-CD-IL). These methods are new, green, and simple extraction technique to couple with a reversed-phase high-performance liquid chromatography to get the optimum conditions for phase separation of parabens in water samples. The parameters, i.e. pH of the solution, water content, distribution coefficient, and preconcentration factor, are evaluated to get the optimum conditions for phase separation of parabens. The CPE-DC193C-CD-IL method shows the highest losses of water content among other methods. It also produces the highest preconcentration factor and distribution coefficient. The lowest limit of detection of parabens in water samples is also demonstrated by the CPE-DC193C-CD-IL method. The CPE-DC193C-CD-IL method gives an excellent performance on the detection of parabens from water samples with limit of detections are in the range of 0.017-0.043g/L with the percentage recoveries 90.5-98.9%. To conclude, the CPE-DC193C-CD-IL method is a superior method in the determination of parabens from water samples among the developed methods. The use of -CD is an economically viable approach because it improves the performance of paraben extraction method dramatically. In addition, this surfactant is cheap and non-toxic to our environment.
引用
收藏
页码:22353 / 22361
页数:9
相关论文
共 50 条
  • [41] Use of cloud point extraction methodology for the determination of PAHs priority pollutants in water samples by high-performance liquid chromatography with fluorescence detection and wavelength programming
    Ferrer, R
    Beltran, JL
    Guiteras, J
    ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) : 199 - 206
  • [42] Simultaneous Determination of Six Parabens in Foods by Matrix Liquid-Phase Dispersion Extraction Combined with High-Performance Liquid Chromatography
    Yang, Jinling
    Li, Yongxin
    Gong, Weilei
    Wang, Changqin
    Liu, Bencheng
    Sun, Chengjun
    FOOD ANALYTICAL METHODS, 2014, 7 (08) : 1693 - 1702
  • [43] High-performance extraction of alkaloids using aqueous two-phase systems with ionic liquids
    Freire, Mara G.
    Neves, Catarina M. S. S.
    Marrucho, Isabel M.
    Lopes, Jose N. Canongia
    Rebelo, Luis Paulo N.
    Coutinho, Joao A. P.
    GREEN CHEMISTRY, 2010, 12 (10) : 1715 - 1718
  • [44] Cloud point extraction and high-performance liquid chromatographic determination of selected herbicides
    Halko, R
    Hutta, M
    FRESENIUS ENVIRONMENTAL BULLETIN, 2002, 11 (01): : 22 - 26
  • [45] Determination of four parabens in cosmetics by high-performance liquid chromatography with magnetic solid-phase and ionic dispersive liquid liquid extraction
    Gao, Xun
    Xu, Kai
    Chi, Miaomiao
    Li, Jiaojiao
    Suo, Lingzhe
    Zhu, Lin
    Chen, Kexin
    Mu, Jingqing
    REVIEWS IN ANALYTICAL CHEMISTRY, 2021, 40 (01) : 161 - 172
  • [46] Cloud-point extraction and reversed-phase high-performance liquid chromatography for the determination of carbamate insecticide residues in fruits
    Santalad, Apichai
    Srijaranai, Supalax
    Burakham, Rodjana
    Glennon, Jeremy D.
    Deming, Richard L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (05) : 1307 - 1317
  • [47] Cloud-point extraction and reversed-phase high-performance liquid chromatography for the determination of carbamate insecticide residues in fruits
    Apichai Santalad
    Supalax Srijaranai
    Rodjana Burakham
    Jeremy D. Glennon
    Richard L. Deming
    Analytical and Bioanalytical Chemistry, 2009, 394 : 1307 - 1317
  • [48] On-line preconcentration with solid-phase extraction for the determination of phenol and chlorophenols in aqueous samples by high-performance liquid chromatography
    Jung, MW
    Lee, DW
    Rhee, JS
    Paeng, KJ
    ANALYTICAL SCIENCES, 1996, 12 (06) : 981 - 984
  • [49] Co-precipitation assisted cloud point extraction coupled with high performance liquid chromatography for the determination of estrogens in water and cosmetic samples
    Xiao, Xiaohua
    Chen, Xiaoguang
    Xu, Xianfang
    Li, Gongke
    ANALYTICAL METHODS, 2013, 5 (22) : 6376 - 6381
  • [50] Quantification of the antifungal lipopeptide iturin A by high performance liquid chromatography coupled with aqueous two-phase extraction
    Yuan, Jun
    Raza, Waseem
    Huang, Qiwei
    Shen, Qirong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (26): : 2746 - 2750