A Standalone and Portable Microfluidic Imaging Detection System With Embedded Computing for Point-of-Care Diagnostics

被引:8
|
作者
Wang, Renjie [1 ]
Huang, Xiwei [1 ]
Xu, Xuefeng [1 ]
Sun, Jingjing [1 ]
Zheng, Sikai [1 ]
Ke, Xiang [1 ]
Yao, Jiangfan [1 ]
Han, Wentao [1 ]
Wei, Maoyu [1 ]
Chen, Jin [1 ]
Gao, Haijun [1 ]
Guo, Jinhong [2 ]
Sun, Lingling [1 ]
机构
[1] Hangzhou Dianzi Univ, Key Lab RF Circuits & Syst, Minist Educ, Hangzhou 310018, Peoples R China
[2] Univ Elect Sci & Technol China, Sch Informat & Commun Engn, Chengdu 611731, Peoples R China
基金
中国国家自然科学基金;
关键词
Standalone; microfluidic imaging; cell counting; POCT; LABEL-FREE; HIGH-THROUGHPUT; MICROSCOPY; DEVICE; TUMOR;
D O I
10.1109/JSEN.2022.3148768
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The existing imaging flow cytometers for cell detection usually require special optical microscope systems, high-speed cameras, and precision injection pumps, which are not applicable for point-of-care (POC) diagnostics. Recently, there are some portable cell imaging detection systems proposed, however, most of them just miniaturize the imaging part yet still rely on external personal computers to realize the system control, image storage, processing, and display. To address these challenges, we propose a standalone and portable microfluidic imaging detection system with embedded computing. The fully self-contained system integrates a portable microfluidic image acquisition module, a light source module, an embedded computing and control module, a micropump module, a touch control panel module, and a power supply module to realize bio-sample detection, processing, and result display functions with 1.9 kg weight and 20(L) x 10(W) x 15(H) cm(3) size. Experimental results showed that the system could clearly image human blood cells, tumor cells, and microspheres of different sizes. Under the flow rate of 1 mu L/min, the classification and counting accuracy of the system can reach over 99.7% for 10 mu m and 15 mu m particles in either single or mixed microbead sample solution, and reach 95.96% for HepG2 (Human hepatocellular carcinomas) cells in mixed cell and microbead sample solution. This system can automatically collect and analyze cells without being in the laboratory, which enables a shortened time-to-result cell detection approach. Therefore, we believe that the portable cell analysis equipment could provide a promising solution for future POC diagnostics.
引用
收藏
页码:6116 / 6123
页数:8
相关论文
共 50 条
  • [21] Advances in microfluidic PCR for point-of-care infectious disease diagnostics
    Park, Seungkyung
    Zhang, Yi
    Lin, Shin
    Wang, Tza-Huei
    Yang, Samuel
    BIOTECHNOLOGY ADVANCES, 2011, 29 (06) : 830 - 839
  • [22] FINGER-POWERED BEAD-IN-DROPLET MICROFLUIDIC SYSTEM FOR POINT-OF-CARE DIAGNOSTICS
    Iwai, K.
    Sochol, R. D.
    Lee, L. P.
    Lin, L.
    2012 IEEE 25TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2012,
  • [23] Microfluidic system for rapid detection of contagious bovine pleuropneumonia at the point-of-care
    Nepper, Julia F.
    Liljander, Anne
    Irizarry, Pedro J. Resto
    Zan, Jindong
    Jores, Joeerg
    Weibel, Douglas B.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [24] Microfluidic Point-of-Care Diagnostics for Multi-Disease Detection Using Optical Techniques: A Review
    Ahmadsaidulu, Shaik
    Banik, Oindrila
    Kumar, Prasoon
    Kumar, Santosh
    Banoth, Earu
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2024, 23 (01) : 140 - 147
  • [25] Compact point-of-care system for clinical diagnostics
    Kemmler, Manuel
    Koger, Birgit
    Sulz, Gerd
    Sauer, Ursula
    Schleicher, Erwin
    Preininger, Claudia
    Brandenburg, Albrecht
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (01) : 44 - 51
  • [26] Portable biosensing devices for point-of-care diagnostics: Recent developments and applications
    Zarei, Mohammad
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 91 : 26 - 41
  • [27] Picoliter droplet microfluidic immunosorbent platform for point-of-care diagnostics of tetanus
    Golberg, Alexander
    Yarmush, Martin L.
    Konry, Tania
    MICROCHIMICA ACTA, 2013, 180 (9-10) : 855 - 860
  • [28] Direct hemoglobin measurement on a centrifugal microfluidic platform for point-of-care diagnostics
    Steigert, J.
    Grumann, M.
    Dube, M.
    Streule, W.
    Riegger, L.
    Brenner, T.
    Koltay, P.
    Mittmann, K.
    Zengerle, R.
    Ducree, J.
    SENSORS AND ACTUATORS A-PHYSICAL, 2006, 130 (SPEC. ISS.) : 228 - 233
  • [29] Reagent storage and delivery on integrated microfluidic chips for point-of-care diagnostics
    Rasekh, Manoochehr
    Harrison, Sam
    Schobesberger, Silvia
    Ertl, Peter
    Balachandran, Wamadeva
    BIOMEDICAL MICRODEVICES, 2024, 26 (03)
  • [30] Picoliter droplet microfluidic immunosorbent platform for point-of-care diagnostics of tetanus
    Alexander Golberg
    Martin L. Yarmush
    Tania Konry
    Microchimica Acta, 2013, 180 : 855 - 860