The Use of Infrared Thermography as a Rapid, Quantitative, and Noninvasive Method for Evaluation of Inflammation Response in Different Anatomical Regions of Rats

被引:23
|
作者
Calkosinski, Ireneusz [1 ]
Dobrzynski, Maciej [2 ]
Rosinczuk, Joanna [1 ]
Dudek, Krzysztof [3 ]
Chroszcz, Aleksander [4 ]
Fita, Katarzyna [2 ]
Dymarek, Robert [1 ]
机构
[1] Wroclaw Med Univ, Fac Hlth Sci, Dept Nervous Syst Dis, PL-51618 Wroclaw, Poland
[2] Wroclaw Med Univ, Fac Dent, Dept Conservat Dent & Pedodont, PL-50425 Wroclaw, Poland
[3] Tech Univ Wroclaw, Inst Machines Design & Operat, PL-50371 Wroclaw, Poland
[4] Wroclaw Univ Environm & Life Sci, Fac Vet Med, Dept Anim Physiol & Biostruct, PL-51631 Wroclaw, Poland
关键词
RECOMBINANT HUMAN INTERLEUKIN-6; TEMPERATURE; PARAMETERS; INDUCTION; PROTEIN;
D O I
10.1155/2015/972535
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. Thermographic assessment of temperature distribution within the examined tissues allows a quick, noncontact, noninvasive measurement of their temperature. The aim of the study was to evaluate the usefulness of digital infrared imaging in monitoring experimental inflammation of pleura (PL), lower lip (LL), and left paw (LP) and right paw (RP) of lower limbs in rats. Materials and Methods. The inflammatory reaction was induced by injection of 1% carrageenin solution into pleural cavity, lip, or paws. With the use of digital infrared imaging temperature measurement was conducted at 0 to 72 hours of the inflammatory reaction. Results. The temperature decrease was observed at the site of injection directly afterwards. Next, it was gradually increasing and it reached the maximum on the third day of the inflammatory reaction. Statistically significant changes were observed after 48-hour period in PL and LL regions, as well as after 72-hour period in LP and RP regions (P < 0.005). Conclusion. It was found that thermographic examination allows for indicating the presence of inflammatory reaction within examined tissues and determining the dynamics of this process. This method could be used as alternative procedure that allows using fewer animals for experiments.
引用
收藏
页数:9
相关论文
共 11 条
  • [1] Surface temperature in different anatomical regions of ewes measured by infrared thermography
    Barros de Freitas, Ana Carolina
    Quirino, Celia Raquel
    Bartholazzi Junior, Aylton
    Ortiz Vega, Wilder Hernando
    Gomes David, Caroline Marcal
    Geraldo, Andre Torres
    Silva Rua, Miguel Alejandro
    Cipagauta Rojas, Luisa Fernanda
    de Almeida Filho, Janeo Eustaquio
    Burla Dias, Angelo Jose
    [J]. LIVESTOCK SCIENCE, 2018, 216 : 84 - 87
  • [2] Evaluation of infrared thermography as a method for diagnosing inflammation of the leg joints in fattening pigs
    Savary, P.
    Hauser, R.
    Ossent, P.
    Jungbluth, T.
    Gygax, L.
    Wechsler, B.
    [J]. DEUTSCHE TIERARZTLICHE WOCHENSCHRIFT, 2008, 115 (09): : 324 - 329
  • [3] Evaluation of temperature on different wheelchair cushions using infrared thermography method
    He Thong Bui
    Quang Bang Tao
    Philippe Lestriez
    Karl Debray
    Redha Taiar
    Van Thanh Hoang
    [J]. Journal of Mechanical Science and Technology, 2023, 37 : 1455 - 1462
  • [4] Evaluation of temperature on different wheelchair cushions using infrared thermography method
    Bui, He Thong
    Tao, Quang Bang
    Lestriez, Philippe
    Debray, Karl
    Taiar, Redha
    Hoang, Van Thanh
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (03) : 1455 - 1462
  • [5] Use of infrared thermography for quantitative non-destructive evaluation in FRP strengthened bridge systems
    Ghosh, Kumar K.
    Karbhari, Vistasp M.
    [J]. MATERIALS AND STRUCTURES, 2011, 44 (01) : 169 - 185
  • [6] Use of infrared thermography for quantitative non-destructive evaluation in FRP strengthened bridge systems
    Kumar K. Ghosh
    Vistasp M. Karbhari
    [J]. Materials and Structures, 2011, 44 : 169 - 185
  • [7] An infrared thermography-based method for the evaluation of the thermal response of tooling for composites manufacturing
    Zobeiry, Navid
    Park, John
    Poursartip, Anoush
    [J]. JOURNAL OF COMPOSITE MATERIALS, 2019, 53 (10) : 1277 - 1290
  • [8] Evaluation of infrared thermography as a non-invasive method of measuring the autonomic nervous response in sheep
    Sutherland, Mhairi A.
    Worth, Gemma M.
    Dowling, Suzanne K.
    Lowe, Gemma L.
    Cave, Vanessa M.
    Stewart, Mairi
    [J]. PLOS ONE, 2020, 15 (05):
  • [9] Alternative data evaluation methodology for infrared thermography analogous to the Shock Response Spectrum analysis method
    Yagdjian, Harutyun
    Gurka, Martin
    [J]. NDT & E INTERNATIONAL, 2024, 146
  • [10] Eye surface infrared thermography usefulness as a noninvasive method of measuring stress response in sheep during shearing: Correlations with serum cortisol and rectal temperature values
    Arfuso, Francesca
    Acri, Giuseppe
    Piccione, Giuseppe
    Sansotta, Carlo
    Fazio, Francesco
    Giudice, Elisabetta
    Giannetto, Claudia
    [J]. PHYSIOLOGY & BEHAVIOR, 2022, 250