Spectral imaging with dual-layer spectral detector computed tomography for the detection of perfusion defects in acute coronary syndrome

被引:8
|
作者
Mochizuki, Junji [1 ]
Nakaura, Takeshi [2 ]
Yoshida, Naofumi [2 ]
Nagayama, Yasunori [2 ]
Kidoh, Masafumi [2 ]
Uetani, Hiroyuki [2 ]
Funama, Yoshinori [3 ]
Hata, Yoshiki [1 ]
Azuma, Minako [3 ]
Hirai, Toshinori [2 ]
机构
[1] Minamino Cardiovasc Hosp, 1-25-1 Hyoue, Hachioji, Tokyo 1920918, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, 1-1-1 Honjo, Kumamoto, Kumamoto 8608556, Japan
[3] Kumamoto Univ, Fac Life Sci, Dept Med Phys, Kumamoto, Japan
关键词
Dual-energy scanned projection; Multidetector computed tomography; Acute coronary syndrome; Myocardial perfusion; MYOCARDIAL-PERFUSION; DIAGNOSTIC-ACCURACY; CT; RECONSTRUCTIONS; PATHOPHYSIOLOGY; ANGIOGRAPHY;
D O I
10.1007/s00380-021-02019-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the feasibility of spectral imaging with dual-layer spectral detector computed tomography (CT) for the diagnosis of acute coronary syndrome. We identified 30 consecutive patients who underwent cardiac CT using dual-layer spectral detector CT and were diagnosed with acute ischemic syndrome by an invasive coronary angiography. We reconstructed 120 kVp images and generated virtual monochromatic images (VMIs; 40-200 keV in 10 keV increments), iodine concentration maps, and effective atomic number (Z) maps. We calculated the contrast and contrast-to-noise ratio (CNR) between myocardial normal and hypo-perfusion and chose the VMIs with the best CNR for quantitative analysis. We compared the image noise, contrast, and CNR of 120 kVp images and the best VMIs, CT value, iodine concentration, and effective Z between myocardial normal and hypo-perfusion with the paired t test. As the X-ray energy decreased, venous attenuation, contrast, and CNR gradually increased. The 40 keV image yielded the best CNR. The contrast and CNR between myocardial normal and hypo-perfusion were significantly higher in 40 keV images than those in 120 kVp images. The iodine concentration and the effective Z were significantly higher in normal myocardium than those in hypo-perfused myocardium. Spectral imaging with dual-layer spectral detector CT is a feasible technique to detect the hypo-perfused area of acute ischemic syndrome.
引用
收藏
页码:1115 / 1124
页数:10
相关论文
共 50 条
  • [21] Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading
    Mu, Ronghua
    Meng, Zhuoni
    Guo, Zixuan
    Qin, Xiaoyan
    Huang, Guangyi
    Yang, Xuri
    Jin, Hui
    Yang, Peng
    Zhang, Xiaodi
    Zhu, Xiqi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, : 4601 - 4611
  • [22] A Retrospectively Study: Diagnosis of Pathological Types of Malignant Lung Tumors by Dual-layer Detector Spectral Computed Tomography
    Ma, Xia
    Xu, Ming
    Tian, Xiao-Juan
    Liu, Yong-Li
    Zhang, Xin-Ri
    Qiao, Ying
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [23] Detection of axillary lymph node metastasis in breast cancer using dual-layer spectral computed tomography
    Li, Huijun
    Wang, Huan
    Chen, Fangfang
    Gao, Lei
    Zhou, Yurong
    Zhou, Zhou
    Huang, Jinbai
    Xu, Liying
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [24] Usefulness and limitations of dual-layer spectral detector computed tomography for diagnosing biliary stones not detected by conventional computed tomography: a report of three cases
    Saito H.
    Noda K.
    Ogasawara K.
    Atsuji S.
    Takaoka H.
    Kajihara H.
    Nasu J.
    Morishita S.
    Matsushita I.
    Katahira K.
    Clinical Journal of Gastroenterology, 2018, 11 (2) : 172 - 177
  • [25] Dual-layer spectral computed tomography aortography using a seventy-five-percent-reduced iodine dose protocol and multiparameter spectral imaging: comparison with conventional computed tomography imaging
    Wang, Aijie
    Li, Wanjiang
    Huang, Wenyu
    Luo, Mao
    Xiao, Wendan
    Qin, Chaoyi
    Dong, Shushan
    Liu, Haiwei
    Li, Zhenlin
    Diao, Kaiyue
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (10) : 6456 - +
  • [26] Association of liver multi-parameter quantitative metrics determined by dual-layer spectral detector computed tomography (SDCT) with coronary plaque scores
    Wang, Min
    Ma, Yue
    Lan, Yu
    Bai, Ruobing
    Yang, Linlin
    Hou, Yang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (10) : 7392 - 7405
  • [27] Evaluation of Virtual Monoenergetic Images on Pulmonary Vasculature Using the Dual-Layer Detector-Based Spectral Computed Tomography
    Ghandour, Abed
    Sher, Andrew
    Rassouli, Negin
    Dhanantwari, Amar
    Rajiah, Prabhakar
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 858 - 865
  • [28] Pericoronary adipose tissue attenuation assessed by dual-layer spectral detector computed tomography is a sensitive imaging marker of high-risk plaques
    Chen, Xujiao
    Dang, Yuxue
    Hu, Hong
    Ma, Shaowei
    Ma, Yue
    Wang, Kunhua
    Liu, Ting
    Lu, Xiaomei
    Hou, Yang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (05) : 2093 - 2103
  • [29] Non-Invasive Imaging in Pulmonary Hypertension - Comprehensive Assessment Using Dual-Layer Spectral Computed Tomography -
    Oda, Seitaro
    Kidoh, Masafumi
    Nagayama, Yasunori
    Nakaura, Takeshi
    Hirakawa, Kyoko
    Yamamoto, Eiichiro
    Tsujita, Kenichi
    Hirai, Toshinori
    CIRCULATION JOURNAL, 2021, 85 (03) : 316 - +
  • [30] Predicting coronary atherosclerosis heart disease with pericoronary adipose tissue attenuation parameters based on dual-layer spectral detector computed tomography: a preliminary exploration
    Zou, Lei
    Xiao, Xigang
    Jia, Yulin
    Yin, Feng
    Zhu, Jing
    Gao, Qi
    Xue, Ming
    Dong, Shushan
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (05) : 2975 - 2988