Spectrometric measurements of 131I and 99mTc activity in thyroid

被引:4
|
作者
Osko, J.
Golnik, N.
Pliszczynski, T.
机构
[1] Warsaw Univ Technol, Inst Precis & Biomed Engn, PL-02525 Warsaw, Poland
[2] Inst Atom Energy, PL-05400 Otwock, Poland
关键词
activity measurements; thyroid; iodine; technetium;
D O I
10.1016/j.nima.2007.05.238
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A modified method for calibration of the thyroid counter with I-131 was investigated in order to take into account the depth of the thyroid in human neck. The depth of the I-131 source was determined from the ratio of the counting rate in 364 keV peak to the counting rate in the energy band of 110-140 keV. Dependence of detector efficiency on the source depth was determined. The results were used for analysis of the energy spectra recorded for hospital patients. Similar method was investigated also for Tc-99m radiation source. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:578 / 581
页数:4
相关论文
共 50 条
  • [41] Comparison for quality assurance of 99mTc activity measurements with radionuclide calibrators
    Kossert, K.
    Thieme, K.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (07) : 866 - 871
  • [42] Shielding efficiency of novel tungsten rubber against radionuclides of 99mTc, 131I, 18F and 68Ga
    Kijima, Kenta
    Krisanachinda, Anchali
    Pasawang, Panya
    Hanaoka, Kohei
    Monzen, Hajime
    Nishimura, Yasumasa
    RADIATION PHYSICS AND CHEMISTRY, 2020, 172 (172)
  • [43] 99mTc reduces clonogenic survival after intracellular uptake in NIS-positive cells in vitro more than 131I
    Wendisch, M.
    Freudenberg, R.
    Drechsel, J.
    Runge, R.
    Wunderlich, G.
    Kotzerke, J.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2010, 49 (04): : 154 - 160
  • [44] USE OF 99MTC FOR THYROID SCANNING AND THYROID FUNCTION TESTING
    TOTHILL, P
    IRVINE, WJ
    BRITISH JOURNAL OF RADIOLOGY, 1967, 40 (469): : 78 - &
  • [45] The standardization methods of radioactive sources (125I, 131I, 99mTc, and 18F) for calibrating nuclear medicine equipment in Indonesia
    Wurdiyanto, G.
    Candra, H.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [46] Visualization and quantification of mouse thyroid gland 99mTc and 131I-uptake by a small animal SPECT/CT system
    Mathe, D.
    Foldes, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S398 - S398
  • [47] Measurements of 131I activity in thyroid of workers at the place of radioiodine therapy in 38 hospitals in China
    Li, Xiao-Liang
    Zhang, Jian-Feng
    Wang, Shuo
    Liu, Jian-Xiang
    Tuo, Fei
    Sun, Quan-Fu
    JOURNAL OF RADIATION RESEARCH, 2024, : 459 - 466
  • [48] Low activity treatment with 131I in differentiated thyroid cancer
    Olivan-Sasot, P.
    Prado-Wohlwend, S.
    Sanchez-Vano, R.
    Yepes-Agudelo, A.
    Agudelo-Cifuentes, M.
    Bernal-Vergara, J.
    Bello-Arques, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S608 - S609
  • [49] Prescribed Activity of 131I Therapy in Differentiated Thyroid Cancer
    Van Nostrand, Douglas
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (05) : 697 - 699
  • [50] 含碘食物对Graves病患者甲状腺131I与99mTc摄取的不同影响
    何国荣
    欧阳伟
    刘金华
    刘伟英
    第一军医大学学报, 2004, (11) : 1292 - 1294