Development of a real-time reverse transcription loop-mediated isothermal amplification method for the rapid detection of porcine epidemic diarrhea virus

被引:38
|
作者
Yu, Xuewu [1 ,2 ]
Shi, Lin [1 ,2 ]
Lv, Xiaoping [1 ]
Yao, Wei [2 ]
Cao, Minghui [3 ]
Yu, Hanxun [4 ]
Wang, Xiurong [5 ,6 ]
Zheng, Shimin [1 ]
机构
[1] Northeast Agr Univ, Coll Vet Med, Harbin 150030, Peoples R China
[2] Anim Epidem Dis Control & Prevent Ctr Liaoning Pr, Shenyang, Peoples R China
[3] China Inst Vet Drugs Control, Beijing, Peoples R China
[4] Anim Epidem Dis Control & Prevent Ctr Dalian City, Dalian, Peoples R China
[5] Chinese Acad Agr Sci, Harbin Vet Res Inst, Animal Influenza Lab, Minist Agr, Harbin, Peoples R China
[6] Chinese Acad Agr Sci, Harbin Vet Res Inst, State Key Lab Vet Biotechnol, Harbin, Peoples R China
来源
VIROLOGY JOURNAL | 2015年 / 12卷
关键词
PEDV; RT-LAMP; Detection; TRANSMISSIBLE GASTROENTERITIS VIRUS; CELL-CULTURE; RT-PCR; VARIANT; CHINA; STRAINS; PROTEIN; SWINE; GENE;
D O I
10.1186/s12985-015-0297-1
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Porcine epidemic diarrhea (PED) is an acute and highly contagious enteric disease characterized by severe enteritis, vomiting and watery diarrhea in swine. Recently, the outbreak of the epidemic disease has been a serious problem in swine industry. The objective of this study is to develop a rapid, sensitive, and real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the detection of porcine epidemic diarrhea virus (PEDV) in less equipped laboratories. Results: The optimal reaction condition of the current real-time RT-LAMP for PEDV was 62 degrees C for 45 min. It was capable of detecting PEDV from clinical samples and differentiating PEDV from several related porcine viruses, while it did not require additional expensive equipment. The minimum detection limit of the real-time RT-LAMP assay was 0.07PFU per reaction for PEDV RNA, making this assay approximately 100-fold more sensitive than that of one-step RT-PCR. By screening a panel of clinical specimens, the results showed that this method presented a similar sensitivity with real-time RT-PCR and was somewhat sensitive than one-step RT-PCR in detection of clinical samples. Conclusions: In this study, we have developed a new real-time RT-LAMP method, which is rapid, sensitive and efficient to detect PEDV. This method holds great promises not only in laboratory detection and discrimination of PEDV but also in large scale field and clinical studies.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Development of real-time fluorescent reverse transcription loop-mediated isothermal amplification assays for rhinovirus detection
    Nakauchi, Mina
    Takayama, Ikuyo
    Takahashi, Hitoshi
    Semba, Shohei
    Saito, Shinji
    Kubo, Hideyuki
    Kaida, Atsushi
    Oba, Kunihiro
    Nagata, Shiho
    Odagiri, Takato
    Kageyama, Tsutomu
    JOURNAL OF MEDICAL VIROLOGY, 2019, 91 (07) : 1232 - 1238
  • [22] Rapid Detection of Porcine Reproductive and Respiratory Syndrome Virus by Reverse Transcription Loop-Mediated Isothermal Amplification
    Qin, Chen
    Jian, Li
    Xue-En, Fang
    Wei, Xiong
    INTERVIROLOGY, 2009, 52 (02) : 86 - 91
  • [23] Real-time reverse transcription recombinase polymerase amplification assay for rapid detection of porcine epidemic diarrhea virus
    Wang, Jianchang
    Zhang, Ruoxi
    Wang, Jinfeng
    Han, Qingan
    Liu, Libing
    Li, Yanan
    Yuan, Wanzhe
    JOURNAL OF VIROLOGICAL METHODS, 2018, 253 : 49 - 52
  • [24] Rapid detection of porcine kobuvirus in feces by reverse transcription loop-mediated isothermal amplification
    Changlong Li
    Jianfei Chen
    Hongyan Shi
    Xin Zhang
    Da Shi
    Xiao Han
    Yanbin Chi
    Li Feng
    Virology Journal, 11
  • [25] Rapid detection of porcine kobuvirus in feces by reverse transcription loop-mediated isothermal amplification
    Li, Changlong
    Chen, Jianfei
    Shi, Hongyan
    Zhang, Xin
    Shi, Da
    Han, Xiao
    Chi, Yanbin
    Feng, Li
    VIROLOGY JOURNAL, 2014, 11
  • [26] Rapid and reliable diagnostic method to detect Zika virus by real-time fluorescence reverse transcription loop-mediated isothermal amplification
    Xu-Guang Guo
    Yong-Zhuo Zhou
    Qin Li
    Wei Wang
    Jin-Zhou Wen
    Lei Zheng
    Qian Wang
    AMB Express, 8
  • [27] Rapid and reliable diagnostic method to detect Zika virus by real-time fluorescence reverse transcription loop-mediated isothermal amplification
    Guo, Xu-Guang
    Zhou, Yong-Zhuo
    Li, Qin
    Wang, Wei
    Wen, Jin-Zhou
    Zheng, Lei
    Wang, Qian
    AMB EXPRESS, 2018, 8
  • [28] Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of SARS-CoV-2
    Lau, Yee Ling
    Ismail, Ilyiana
    Mustapa, Nur Izati
    Lai, Meng Yee
    Soh, Tuan Suhaila Tuan
    Hassan, Afifah
    Peariasamy, Kalaiarasu M.
    Lee, Yee Leng
    Chong, Yoong Min
    Sam, I-Ching
    Goh, Pik Pin
    PEERJ, 2020, 8
  • [29] Development of a Real-Time Loop-Mediated Isothermal Amplification Method for the Detection of West Nile Virus
    Lee, Jae Woong
    Won, Yu-Jung
    Lee, Sung-Geun
    Paik, Soon-Young
    JUNDISHAPUR JOURNAL OF MICROBIOLOGY, 2020, 13 (10) : 1 - 6
  • [30] Development of a reverse transcription loop-mediated isothermal amplification assay for detection of Porcine teschovirus
    Wang, Bin
    Wang, Yongqiang
    Tian, Zhi-Jun
    An, Tong-Qing
    Peng, Jin-Mei
    Tong, Guang-Zhi
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2011, 23 (03) : 516 - 518