Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T

被引:82
|
作者
Fernández-Seara, MA
Wang, Z
Wang, JJ
Rao, HY
Guenther, M
Feinberg, DA
Detre, JA
机构
[1] Univ Penn, Med Ctr, Dept Neurol, Ctr Funct Neuroimaging, Philadelphia, PA 19104 USA
[2] Univ Penn, Med Ctr, Dept Radiol, Philadelphia, PA 19104 USA
[3] Adv MRI Technol, Sebastopol, CA USA
关键词
perfusion MRI; arterial spin labeling; human brain; cerebral blood flow; 3D GRASE imaging;
D O I
10.1002/mrm.20674
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single shot 3D GRASE is less sensitive to field inhomogeneity and susceptibility effects than gradient echo based fast imaging sequences while preserving the acquisition speed. In this study, a continuous arterial spin labeling (CASL) pulse was added prior to the single shot 3D GRASE readout and quantitative perfusion measurements were carried out at 3 T, at rest and during functional activation. The sequence performance was evaluated by comparison with a CASL sequence with EPI readout. It is shown that perfusion measurements using CASL GRASE can be performed safely on humans at 3 T without exceeding the current RF power deposition limits. The maps of resting cerebral blood flow generated from the GRASE images are comparable to those obtained with the 2D EPI readout, albeit with better coverage in the orbitofrontal cortex. The sequence proved effective for functional imaging, yielding time series of images with improved temporal SNR with respect to EPI and group activation maps with increased significance levels. The method was further improved using parallel imaging techniques to provide increased spatial resolution and better separation of the gray-white matter cerebral blood flow maps.
引用
收藏
页码:1241 / 1247
页数:7
相关论文
共 50 条
  • [21] Cerebral perfusion measurements using continuous arterial spin labeling: accuracy and limits of a quantitative approach
    Kimura, H
    Kabasawa, H
    Yonekura, Y
    Itoh, H
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 238 - 247
  • [22] Intra- and Interscanner Reliability and Reproducibility of 3D Whole-Brain Pseudo-Continuous Arterial Spin-Labeling MR Perfusion at 3T
    Wu, Bing
    Lou, Xin
    Wu, Xinhuai
    Ma, Lin
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 402 - 409
  • [23] 3D GRASE arterial spin labelling reveals an inverse correlation of cortical perfusion with the white matter lesion volume in MS
    Amann, Michael
    Achtnichts, Lutz
    Hirsch, Jochen G.
    Naegelin, Yvonne
    Gregori, Johannes
    Weier, Katrin
    Thoeni, Alain
    Mueller-Lenke, Nicole
    Radue, Ernst-Wilhelm
    Guenther, Matthias
    Kappos, Ludwig
    Gass, Achim
    MULTIPLE SCLEROSIS JOURNAL, 2012, 18 (11) : 1570 - 1576
  • [24] Efficient 3D cone trajectory design for improved combined angiographic and perfusion imaging using arterial spin labeling
    Shen, Qijia
    Wu, Wenchuan
    Chiew, Mark
    Ji, Yang
    Woods, Joseph G.
    Okell, Thomas W.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1568 - 1583
  • [25] Robust method for 3D arterial spin labeling in mice
    Chugh, Brige Paul
    Bishop, Jonathan
    Zhou, Yu-Qing
    Wu, Jian
    Henkelman, R. Mark
    Sled, John G.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 98 - 106
  • [26] Evaluation of gray matter perfusion in episodic migraine using voxel-wise comparison of 3D pseudo-continuous arterial spin labeling
    Chen, Zhiye
    Chen, Xiaoyan
    Liu, Mengyu
    Liu, Mengqi
    Ma, Lin
    Yu, Shengyuan
    JOURNAL OF HEADACHE AND PAIN, 2018, 19
  • [27] Evaluation of gray matter perfusion in episodic migraine using voxel-wise comparison of 3D pseudo-continuous arterial spin labeling
    Zhiye Chen
    Xiaoyan Chen
    Mengyu Liu
    Mengqi Liu
    Lin Ma
    Shengyuan Yu
    The Journal of Headache and Pain, 2018, 19
  • [28] Reduction of grey matter perfusion in MS patients with high lesion loads - a quantitative arterial spin labelling study using a 3D GRASE sequence at 1.5T
    Amann, M.
    Achtnichts, L.
    Gregori, J.
    Naegelin, Y.
    Hirsch, J.
    Weier, K.
    Thoeni, A.
    Madoerin, P.
    Radue, E. W.
    Kappos, L.
    Guenther, M.
    Gass, A.
    MULTIPLE SCLEROSIS JOURNAL, 2009, 15 (09) : S213 - S214
  • [29] Multi-phase 3D arterial spin labeling brain MRI in assessing cerebral blood perfusion and arterial transit times in children at 3T
    Hu, Houchun H.
    Rusin, Jerome A.
    Peng, Ruiyue
    Shao, Xingfeng
    Smith, Mark
    Krishnamurthy, Ramkumar
    Selvaraj, Bhavani
    Wang, Danny J. J.
    CLINICAL IMAGING, 2019, 53 : 210 - 220
  • [30] Noncontrast dynamic 3D intracranial MR angiography using pseudo-continuous arterial spin labeling (PCASL) and accelerated 3D radial acquisition
    Wu, Huimin
    Block, Walter F.
    Turski, Patrick A.
    Mistretta, Charles A.
    Rusinak, David J.
    Wu, Yijing
    Johnson, Kevin M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (05) : 1320 - 1326