Functional brain Imaging using a blood oxygenation sensitive steady state

被引:70
|
作者
Miller, KL
Hargreaves, BA
Lee, J
Ress, D
deCharms, RC
Pauly, JM
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Psychol, Stanford, CA 94305 USA
关键词
BOLD; oxygenation; functional MRI; neuroimaging;
D O I
10.1002/mrm.10602
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Blood oxygenation level dependent (BOLD) functional MRI (fMRI) is an important method for functional neuroimaging that is sensitive to changes in blood oxygenation related to brain activation. While BOLD imaging has good spatial coverage and resolution relative to other neuroimaging methods (such as positron emission tomography (PET)), it has significant limitations relative to other MRI techniques, including poor spatial resolution, low signal levels, limited contrast, and image artifacts. These limitations derive from the coupling of BOLD functional contrast to sources of image degradation. This work presents an alternative method for fMRI that may over-come these limitations by establishing a blood oxygenation sensitive steady-state (BOSS) that inverts the signal from deoxygenated blood relative to the water signal. BOSS fMRI allows the imaging parameters to be optimized independently of the functional contrast, resulting in fewer image artifacts and higher signal-to-noise ratio (SNR). In addition, BOSS fMRI has greater functional contrast than BOLD. BOSS fMRI requires careful shimming and multiple acquisitions to obtain a precise alignment of the magnetization to the SSFP frequency response. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:675 / 683
页数:9
相关论文
共 50 条
  • [41] Imaging putative foetal cerebral blood oxygenation using susceptibility weighted imaging (SWI)
    Yadav, Brijesh Kumar
    Krishnamurthy, Uday
    Buch, Sagar
    Jella, Pavan
    Hernandez-Andrade, Edgar
    Yeo, Lami
    Korzeniewski, Steven J.
    Trifan, Anabela
    Hassan, Sonia S.
    Haacke, E. Mark
    Romero, Roberto
    Neelavalli, Jaladhar
    EUROPEAN RADIOLOGY, 2018, 28 (05) : 1884 - 1890
  • [42] FUNCTIONAL IMAGING OF THE BRAIN USING SUPERCONDUCTING MAGNETOMETRY
    SINGH, KD
    ENDEAVOUR, 1995, 19 (01) : 39 - 44
  • [43] STEADY-STATE MEASUREMENT OF OXYGENATION CAPACITY - DISCUSSION
    ALLEMAN, JE
    WATER SCIENCE AND TECHNOLOGY, 1985, 17 (08) : 1287 - 1287
  • [44] STEADY-STATE MEASUREMENT OF OXYGENATION CAPACITY - REPLY
    不详
    WATER SCIENCE AND TECHNOLOGY, 1985, 17 (08) : 1287 - 1288
  • [45] Detecting microcirculatory changes in blood oxygen state with steady-state free precession imaging
    Dharmakumar, Rohan
    Qi, Xiuling
    Hong, Juimiin
    Wright, Graham A.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) : 1372 - 1380
  • [46] Brain Biometrics of Steady-State Visual Evoked Potential Functional Networks
    Zhang, Yibo
    Shen, Hui
    Li, Ming
    Hu, Dewen
    IEEE TRANSACTIONS ON COGNITIVE AND DEVELOPMENTAL SYSTEMS, 2023, 15 (04) : 1694 - 1701
  • [47] Oscillating steady-state imaging (OSSI): A novel method for functional MRI
    Guo, Shouchang
    Noll, Douglas C.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 698 - 712
  • [48] Blood oxygenation monitoring using hyperspectral imaging after flap surgery
    Calin, Mihaela Antonina
    Boiangiu, Ileana Carmen
    Parasca, Sorin Viorel
    Miclos, Sorin
    Savastru, Dan
    Manea, Dragos
    SPECTROSCOPY LETTERS, 2017, 50 (03) : 150 - 155
  • [49] Myocardial intensity changes associated with flow stimulation in blood oxygenation sensitive magnetic resonance imaging
    Niemi, P
    Poncelet, BP
    Kwong, KK
    Weisskoff, RM
    Rosen, BR
    Brady, TJ
    Kantor, HL
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) : 78 - 82
  • [50] 6 Improved dark blood imaging of the heart using radial balanced steady-state free precession
    Edelman, Robert R.
    Botelho, Marcos
    Pursnani, Amit
    Giri, Shivraman
    Koktzoglou, Ioannis
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18