Radiation exposure in nuclear medicine: Real-time measurement

被引:3
|
作者
Sylvain, I
Bok, B [1 ]
机构
[1] Hop Beaujon, Dept Nucl Med, F-92110 Clichy, France
[2] X Bichat Univ, Biophys Lab, F-75018 Paris, France
关键词
dosimetry; exposure; electronic dosimeters; personal monitoring; equivalent dose;
D O I
10.1590/S1516-89132002000500015
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
French regulations have introduced the use of electronic dosimeters for personal monitoring of workers. In order to evaluate the exposure from diagnostic procedures to nuclear medicine staff individual whole-body doses were measured daily with electronic (digital) personal dosimeters during 20 consecutive weeks and correlated with the work load of each day. Personal doses remained always below 20 muSv/d under normal working conditions. Radiation exposure levels were highest to tech staff nurses and stretcher-bearers. The extrapolated annual cumulative doses for all staff remained less than 10% of the maximum legal limit,for exposed workers (2 mSv/yr). Electronic dosimeters are not technically justified for routine survey of staff. The high sensitivity and immediate reading of electronic semiconductor dosimeters may become very useful for exposure control under risky working conditions. It may become an important help for optimising radiation protection.
引用
收藏
页码:111 / 114
页数:4
相关论文
共 50 条
  • [21] Using RADFET for the real-time measurement of gamma radiation dose rate
    Andjelkovic, Marko S.
    Ristic, Goran S.
    Jaksic, Aleksandar B.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (02)
  • [22] REAL-TIME SYNCHROTRON PHASE DETECTION BY THE ELECTROOPTICAL MEASUREMENT OF SYNCHROTRON RADIATION
    OGATA, A
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1993, 32 (3A): : L346 - L348
  • [23] OCCUPATIONAL RADIATION EXPOSURE IN NUCLEAR-MEDICINE
    FRANK, KD
    KUNKEL, R
    MUTH, H
    GLOBEL, B
    HEALTH PHYSICS, 1983, 44 (02): : 192 - 192
  • [24] RADIATION EXPOSURE OF PATIENT IN NUCLEAR-MEDICINE
    DEROO, M
    JOURNAL BELGE DE RADIOLOGIE, 1973, 56 (02): : 175 - 183
  • [25] Measurement of longitudinal nuclear spin relaxation time in NMR gyroscope by real-time monitoring
    Zhang, Yang
    Zheng, Jintao
    Yu, Zaiyang
    Xiong, Zhiqiang
    Wang, Zhiguo
    Luo, Hui
    AIP ADVANCES, 2022, 12 (09)
  • [26] AUDITING REAL-TIME MEASUREMENT
    GARDNER, B
    GLAZEBROOK, TJ
    MORRISON, WR
    RYAN, WH
    WILLIAMS, ML
    AGA 1989 OPERATING SECTION PROCEEDINGS, 1989, : 513 - 519
  • [27] AN EMPHASIS ON REAL-TIME MEASUREMENT
    不详
    MANUFACTURING ENGINEERING, 1982, 89 (05): : 34 - 35
  • [28] Real-time temperature measurement
    Atlas Material Testing Technology LLC, Chicago, IL
    不详
    Finsh. Today, 2008, 2 (28-31):
  • [29] Radiation Exposure Analysis of Female Nuclear Medicine Radiation Workers
    Lee, J.
    Park, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S643 - S643
  • [30] Effect of Real-Time Radiation Dose Feedback on Pediatric Interventional Radiology Staff Radiation Exposure
    Racadio, John
    Nachabe, Rami
    Carelsen, Bart
    Racadio, Judy
    Hilvert, Nicole
    Johnson, Neil
    Kukreja, Kamlesh
    Patel, Manish
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (01) : 119 - 126