Development of a Gripper with Variable Stiffness for a CT-Guided Needle Insertion Robot

被引:5
|
作者
Yokouchi, Kento [1 ]
Kamegawa, Tetsushi [2 ]
Matsuno, Takayuki [3 ]
Hiraki, Takao [4 ]
Yamaguchi, Takuya [5 ]
Gofuku, Akio [2 ]
机构
[1] Rexxam Co Ltd, 958 Ikeuchi,Konan Cho, Takamatsu, Kagawa 7611494, Japan
[2] Okayama Univ, Grad Sch Interdisciplinary Sci & Engn Hlth Syst, Kita Ku, 3-1-1 Tsushima Naka, Okayama 7008530, Japan
[3] Okayama Univ, Grad Sch Nat Sci & Technol, Kita Ku, 3-1-1 Tsushima Naka, Okayama 7008530, Japan
[4] Okayama Univ, Med Sch, Dept Radiol, Kita Ku, 2-5-1 Shikata Cho, Okayama 7008558, Japan
[5] Okayama Univ Hosp, Dept Med Technol, Div Radiol, Kita Ku, 2-5-1 Shikata Cho, Okayama 7008558, Japan
关键词
medical robot; CT-guided interventional radiology; needle insertion; gripper with variable stiffness; jamming transition phenomenon; COMPUTED-TOMOGRAPHY GUIDANCE; ABLATION; ACCURACY;
D O I
10.20965/jrm.2020.p0692
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
In recent years, interventional radiology (IR) as a medical procedure has attracted considerable attention. Among the various IR techniques, computed tomography (CT)-guided IR is performed by inserting a specific needle into a lesion under CT guidance, leading to this medical procedure being less invasive. However, as the procedure requires the doctor to be positioned near the CT, radiation exposure may be a major concern. To overcome this problem, we developed a remote-controlled robotic system for needle insertion during CT-guided interventional procedures. The current needle holder for the robot is risky in that it might hurt a patient since a needle is always held firmly even when the patient moves. To solve this problem, we designed and fabricated a gripper with variable stiffness through jamming transition. Subsequently, we conducted experiments to investigate the effect of elements constituting the gripper to improve its performance.
引用
收藏
页码:692 / 700
页数:9
相关论文
共 50 条
  • [41] CT-GUIDED AUTOMATED NEEDLE-BIOPSY OF THE CHEST
    HARAMATI, LB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (01) : 53 - 55
  • [42] Special techniques in CT-guided transthoracic needle biopsy
    Nashed, Z
    Klein, JS
    Zarka, MA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (06) : 1665 - 1668
  • [43] BIOPSY AND DRAINAGE OF INTRACEREBRAL LESIONS BY CT-GUIDED NEEDLE
    SAVITZ, MH
    KATZ, SS
    JIMENEZ, JP
    PECK, HM
    MOUNT SINAI JOURNAL OF MEDICINE, 1983, 50 (04): : 326 - 330
  • [44] Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms
    Dupuy, DE
    Rosenberg, AE
    Punyaratabandhu, T
    Tan, MH
    Mankin, HJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) : 759 - 762
  • [45] CT-GUIDED FINE NEEDLE ASPIRATION OF A PERIAORTIC COLLECTION
    KATZ, BH
    BLACK, RA
    COLLEY, DP
    JOURNAL OF VASCULAR SURGERY, 1987, 5 (05) : 762 - 764
  • [46] CT-GUIDED NEEDLE PUNCTURE OF THE CERVICAL SUBARACHNOID SPACE
    NEGIN, GA
    MURTAGH, FR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (04) : 907 - 908
  • [47] ANGULATED NEEDLE PLACEMENT IN CT-GUIDED PERCUTANEOUS NEEDLE-BIOPSY OF THE THORAX
    YANKELEVITZ, DF
    HENSCHKE, CI
    DAVIS, SD
    CLINICAL IMAGING, 1993, 17 (02) : 124 - 125
  • [48] CT-Guided, Minimally Invasive, Postmortem Needle Biopsy Using the B-Rob II Needle-Positioning Robot
    Martinez, Rosa M.
    Ptacek, Wolfgang
    Schweitzer, Wolf
    Kronreif, Gernot
    Fuerst, Martin
    Thali, Michael J.
    Ebert, Lars C.
    JOURNAL OF FORENSIC SCIENCES, 2014, 59 (02) : 517 - 521
  • [49] Improving puncture accuracy in percutaneous CT-guided needle insertion with wireless inertial measurement unit: a phantom study
    Lin, Chia-Ying
    Tang, Wen-Ruei
    Chiang, Po-Chang
    Lien, Jenn-Jier James
    Tseng, Pei-Yi
    Liu, Yi-Sheng
    Chang, Chao-Chun
    Tseng, Yau-Lin
    EUROPEAN RADIOLOGY, 2023, 33 (05) : 3156 - 3164
  • [50] Needle size in CT-guided transthoracic needle aspiration biopsy: Complications and accuracy
    van Rijn, JC
    Bossuyt, PM
    RADIOLOGY, 2004, 232 (01) : 305 - 305