Stronger correlation of peak oxygen uptake with distance of incremental shuttle walk test than 6-min walk test in patients with COPD: a systematic review and meta-analysis

被引:18
|
作者
Chae, Ganghee [1 ]
Ko, Eun Jae [2 ]
Lee, Sei Won [1 ]
Kim, Hyun Jung [3 ]
Kwak, Sang Gyu [4 ]
Park, Donghwi [5 ]
Ra, Seung Won [6 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Pulm & Crit Care Med, Coll Med, Seoul, South Korea
[2] Univ Ulsan, Asan Med Ctr, Dept Rehabil Med, Coll Med, Seoul, South Korea
[3] Korea Univ, Coll Med, Inst Evidence Based Med, Dept Prevent Med, Seoul, South Korea
[4] Catholic Univ Daegu, Coll Med, Dept Med Stat, Daegu, South Korea
[5] Univ Ulsan, Coll Med, Ulsan Univ Hosp, Dept Phys Med & Rehabil, 877 Bangeojinsunhwando Ro, Ulsan 44033, South Korea
[6] Univ Ulsan, Coll Med, Ulsan Univ Hosp, Div Pulm Med,Dept Internal Med, 877 Bangeojinsunhwando Ro, Ulsan 44033, South Korea
关键词
Exercise test; Shuttle walk test; Peak oxygen uptake; Chronic obstructive pulmonary disease; Meta-analysis; OBSTRUCTIVE PULMONARY-DISEASE; CARDIOPULMONARY EXERCISE; FUNCTIONAL-CAPACITY; CYCLE ERGOMETRY; 6-MINUTE-WALK; TREADMILL; WORK;
D O I
10.1186/s12890-022-01897-0
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background The 6-min walk test (6MWT) and incremental shuttle walk test (ISWT) are valid and reliable measures to assess exercise capacity of patients with chronic obstructive pulmonary disease (COPD). However, the comparison of correlation between peak oxygen uptake (peak VO2) and 6MWT or ISWT distance has not been investigated. We aimed to investigate the correlation between peak VO2 and 6MWT and ISWT distances in COPD patients through a meta-analysis. Methods We systematically searched MEDLINE, Scopus, Embase, and the Cochrane Library up to June, 2020 for studies comparing the correlation of peak VO2 with either 6MWT or ISWT in COPD patients. Meta-analysis was performed with R software using a fixed-effect model. We compared the correlation coefficient and measured the heterogeneity using I-2 statistics. Results We identified 12 studies involving 746 patients. Meta-analysis showed a significant correlation between peak VO2 and 6MWT and ISWT distances (6MWT: r = 0.65, 95% CI 0.61-0.70; ISWT: r = 0.81, 95% CI 0.74-0.85; p < 0.0001). The heterogeneity was lower in ISWT than in 6MWT (6MWT: I-2 = 56%, p = 0.02; ISWT: I-2 = 0%, p = 0.71). Subgroup analysis showed a higher correlation coefficient in the low exercise capacity group than in the high exercise capacity group in both field tests. Conclusions 6MWT and ISWT significantly correlated with peak VO2. Our findings suggest that ISWT has a stronger correlation with peak VO2 than 6MWT. The exercise capacity in COPD patients may affect the strength of the relationship between peak VO2 and walking distance in both field tests, suggesting the importance of using various exercise tests. Trial registration CRD 42020200139 at crd.york.ac.uk/prospero/
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Evaluation of Exercise 'Field' Tests (6-Min Walk, Shuttle Test, Step Test) in Assessing Exercise Capacity in COPD and Heart Failure Populations: A Systematic Review
    Kazr, M. H.
    Hadi, A. H.
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2016, 87 : S106 - S106
  • [22] Oxygenation state of the calf muscle during the 6-min walk test in patients with COPD
    Kutsuzawa, Tomoko
    Kurita, Daisaku
    Ikeuchi, Mayumi
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [23] Exercise capacity in COPD patients: Which shows greater improvement, the Incremental Shuttle Walk Test or the 6 Minute Walk Test?
    Lynch, S. M.
    Bowen, B. R.
    Henry, M. T.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : S485 - S485
  • [24] A NEW INTEGRATED INDEX OF 6-MIN WALK TEST FOCUSED ON AN IMPACT OF OXYGEN DESATURATION - APPLICATION TO COPD
    Ijiri, N.
    Kanazawa, H.
    Yoshikawa, T.
    Shirai, A.
    Takeda, N.
    Watanabe, T.
    Kamoi, H.
    Hirata, K.
    RESPIROLOGY, 2014, 19 : 114 - 114
  • [25] Replacement of the 6-min walk test with maximal oxygen consumption in the BODE index applied to patients with COPD - An equivalency study
    Cardoso, Fdbio
    Tufanin, Andrea Thomazine
    Colucci, Marcelo
    Nascimento, Oliver
    Jardim, Jose Roberto
    CHEST, 2007, 132 (02) : 477 - 482
  • [26] Peak oxygen uptake during the incremental shuttle walk test in a predominantly female population with Chagas heart disease
    Alves, Rafael
    Lima, Marcia M.
    Fonseca, Cheyenne
    Dos Reis, Rodrigo
    Figueiredo, Pedro H.
    Costa, Henrique
    Kreuser, Lucas
    Nunes, Maria C.
    Ribeiro, Antonio L.
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2016, 52 (01) : 20 - 27
  • [27] Differences in Walking Pattern during 6-Min Walk Test between Patients with COPD and Healthy Subjects
    Annegarn, Janneke
    Spruit, Martijn A.
    Savelberg, Hans H. C. M.
    Willems, Paul J. B.
    van de Bool, Coby
    Schols, Annemie M. W. J.
    Wouters, Emiel F. M.
    Meijer, Kenneth
    PLOS ONE, 2012, 7 (05):
  • [28] Effects of Baduanjin Exercise on lung function and 6 min walk in COPD patients: a systematic review and meta-analysis
    Song, Feiyun
    Ding, Kexin
    Qi, Wei
    Sun, Wen
    Xiang, Heping
    Sun, Mingyun
    Xia, Rui
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [29] The Clinical Impact of 6-Min Walk Test Distance as a Predictor of Complications in Patients Undergoing Major Surgery
    Kassak, Kassem
    Husari, Ahmad
    WORLD JOURNAL OF SURGERY, 2015, 39 (11) : 2845 - 2845
  • [30] The Clinical Impact of 6-Min Walk Test Distance as a Predictor of Complications in Patients Undergoing Major Surgery
    Kassem Kassak
    Ahmad Husari
    World Journal of Surgery, 2015, 39 : 2845 - 2845