Calibration and characterization of trap detector filter radiometers

被引:4
|
作者
Allen, DW [1 ]
Eppeldauer, GP [1 ]
Brown, SW [1 ]
Early, EA [1 ]
Johnson, BC [1 ]
Lykke, KR [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
来源
EARTH OBSERVING SYSTEMS VIII | 2003年 / 5151卷
关键词
trap detector; radiometer; remote sensing;
D O I
10.1117/12.507995
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
We describe the development of a mechanically simple, radiometrically stable transfer radiometer designed for both radiance and irradiance measurements. The filter radiometer consists of a six-element Si trap detector, a temperature stabilized filter wheel with up to 5 filters, and two precision apertures in a Gershun tube arrangement. With the Gershun tube installed, the instrument operates in radiance mode; with the front aperture removed, in irradiance mode. Two trap detector filter radiometers have been designed and built by the National Institute of Standards and Technology (NIST) for use in remote sensing applications. The filter radiometers have been characterized for optical and electrical performance, and have been calibrated for responsivity using both narrow-band, tunable-laser-illuminated and broad-band, lamp-illuminated integrating sphere sources. This paper describes the filter radiometer design, characterization, and deployments for two remote sensing projects.
引用
收藏
页码:471 / 479
页数:9
相关论文
共 50 条
  • [21] Optical trap detector for calibration of optical fiber powermeters: coupling efficiency
    Lehman, JH
    Cromer, CL
    APPLIED OPTICS, 2002, 41 (31) : 6531 - 6536
  • [22] Characterization of errors in the use of integrating-sphere systems in the calibration of scanning radiometers
    Gatebe, Charles K.
    Butler, James J.
    Cooper, John W.
    Kowalewski, Matthew
    King, Michael D.
    APPLIED OPTICS, 2007, 46 (31) : 7640 - 7651
  • [23] Study on calibration method of filter for linear beam smoke detector
    Yao, Yao
    Tian Yuyu
    Peng, Cheng
    AOPC 2022: OPTOELECTRONICS AND NANOPHOTONICS, 2022, 12556
  • [24] Calibration and Analysis of Entry Vehicle Radiometers
    Cruden, Brett A.
    JOURNAL OF SPACECRAFT AND ROCKETS, 2024, 61 (04) : 1133 - 1137
  • [25] Characterization and calibration of a CCD detector for light engineering
    Fiorentin, P
    Iacomussi, P
    Rossi, G
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (01) : 171 - 177
  • [26] Characterization and calibration of a CCD detector for light engineering
    Fiorentin, P
    Iacomussi, P
    Martignon, A
    Rossi, G
    IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 1087 - 1092
  • [27] Advanced calibration method for sun radiometers
    Xu Q.
    Zheng X.
    Zhang W.
    Wang X.
    Guangxue Xuebao/Acta Optica Sinica, 2010, 30 (05): : 1337 - 1342
  • [28] Characterization of a polarization-independent transmission trap detector
    Kubarsepp, T
    Karha, P
    Ikonen, E
    APPLIED OPTICS, 1997, 36 (13): : 2807 - 2812
  • [29] A new calibration technique for interferometric radiometers
    Corbella, I
    Torres, F
    Camps, A
    Bará, J
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES II, 1998, 3498 : 359 - 366
  • [30] ABSOLUTE CALIBRATION OF FIELD REFLECTANCE RADIOMETERS
    JACKSON, RD
    SLATER, PN
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1986, 52 (02): : 189 - 196