Simultaneous Determination of Ticagrelor and Its Metabolites in Human Plasma and Urine Using Liquid Chromatography-Tandem Mass Spectrometry

被引:19
|
作者
Zhong, Wanping [1 ,2 ]
Wang, Xipei [2 ]
Tang, Lan [1 ]
Mai, Liping [2 ]
Chen, Xiao-Ping [3 ,4 ]
He, Guodong [2 ]
Zheng, Zhijie [2 ]
Zhong, Shilong [2 ]
机构
[1] Southern Med Univ, Sch Pharmaceut Sci, Guangdong Prov Key Lab New Drug Screening, Guangzhou 510515, Guangdong, Peoples R China
[2] Guangdong Acad Med Sci, Guangdong Cardiovasc Inst, Guangdong Gen Hosp, Med Res Ctr, 106 Zhongshan Rd,Weilun Bldg 1112, Guangzhou 510080, Guangdong, Peoples R China
[3] Cent S Univ, Xiangya Hosp, Dept Clin Pharmacol, Changsha 410008, Hunan, Peoples R China
[4] Cent S Univ, Inst Clin Pharmacol, Pharmacogenet Res Inst, Changsha 410008, Hunan, Peoples R China
关键词
PHARMACODYNAMICS; PHARMACOKINETICS; ANTAGONIST; SAFETY;
D O I
10.1093/jat/bkw039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed and validated a rapid, selective and sensitive method using high-performance liquid chromatography-tandem mass spectrometry (MS) for the quantification of ticagrelor and all of its as-yet-identified metabolites in human plasma and urine. For the analysis of ticagrelor, its metabolites and the internal standard (IS) plasma samples were processed by liquid-liquid extraction using ethyl acetate and urine was processed by protein precipitation. Separations were performed on an Ultimate XB-C-18 column (2.1 mm x 150 mm, 3 mu m), using aqueous ammonium acetate (0.025 mM)/acetonitrile (35 : 65, v:v) as the mobile phase. Ticagrelor and all 11 metabolites were eluted within 4.5 min. Quantification was performed using electrospray ionization, operating in negative ion mode. The ticagrelor and metabolite M8 (AR-C124910XX) responses were optimized at the m/z 521.2 -> 361.2 and m/z 477.2 -> 361.1 transitions, respectively. The assay was validated over the linear range of 0.5-2,000 ng/mL for ticagrelor and M8. The intra- and inter-assay precisions were a parts per thousand currency sign14.6% for ticagrelor and a parts per thousand currency sign14.7% for M8, respectively. The matrix effects of plasma and urine were in the range of 98.3-110.7% for ticagrelor and 102.1-112.3% for M8. The relative quantification of other metabolites was performed by assessing the ratio of metabolite to IS peaks. The newly developed method was successfully used in a pharmacokinetic study characterizing ticagrelor metabolism in human volunteers.
引用
收藏
页码:445 / 453
页数:9
相关论文
共 50 条
  • [31] Determination of allopurinol and oxypurinol in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Liu, Xia
    Ni, Xiao-Jia
    Shang, De-Wei
    Zhang, Ming
    Hu, Jin-Qing
    Qiu, Chang
    Luo, Fu-Tian
    Wen, Yu-Guan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 941 : 10 - 16
  • [32] Simultaneous determination of blonanserin and its metabolite in human plasma and urine by liquid chromatography-tandem mass spectrometry: Application to a pharmacokinetic study
    Wen, Yu-Guan
    Ni, Xiao-Jia
    Zhang, Ming
    Liu, Xia
    Shang, De-wei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 903 : 46 - 52
  • [33] Simultaneous determination of omeprazole and its metabolites (5′-hydroxyomeprazole and omeprazole sulfone) in human plasma by liquid chromatography-tandem mass spectrometry
    Ishii, Mikio
    Sato, Masahiko
    Ogawa, Masayuki
    Takubo, Takatoshi
    Hara, Ken-ichi
    Ishii, Yasuyuki
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (9-12) : 1797 - 1810
  • [34] Simultaneous determination of capecitabine and its three nucleoside metabolites in human plasma by high performance liquid chromatography-tandem mass spectrometry
    Deng, Pan
    Ji, Cheng
    Dai, Xiaojian
    Zhong, Dafang
    Ding, Li
    Chen, Xiaoyan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 989 : 71 - 79
  • [35] Simultaneous determination of glimepiride and its metabolites in human plasma by liquid chromatography coupled to a tandem mass spectrometry
    Kyeumhan Noh
    Eunyoung Kim
    Taecheon Jeong
    MinKyun Na
    Moon-Chang Baek
    Kwang-Hyeon Liu
    Pil-Hoon Park
    Beom Soo Shin
    Wonku Kang
    Archives of Pharmacal Research, 2011, 34 : 2073 - 2078
  • [36] Simultaneous Determination of Glimepiride and its Metabolites in Human Plasma by Liquid Chromatography Coupled to a Tandem Mass Spectrometry
    Noh, Kyeumhan
    Kim, Eunyoung
    Jeong, Taecheon
    Na, MinKyun
    Baek, Moon-Chang
    Liu, Kwang-Hyeon
    Park, Pil-Hoon
    Shin, Beom Soo
    Kang, Wonku
    ARCHIVES OF PHARMACAL RESEARCH, 2011, 34 (12) : 2073 - 2078
  • [37] Simultaneous determination of macitentan and its active metabolite in human plasma by liquid chromatography-tandem mass spectrometry
    Yu, Lixiu
    Zhou, Ying
    He, Xiaomeng
    Li, Huqun
    Chen, Hui
    Li, Weiyong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1002 : 358 - 363
  • [38] Simultaneous determination of hypericin and hyperforin in human plasma with liquid chromatography-tandem mass spectrometry
    Riedel, KD
    Rieger, K
    Martin-Facklam, M
    Mikus, G
    Haefeli, WE
    Burhenne, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 27 - 33
  • [39] Simultaneous determination of metformin and glipizide in human plasma by liquid chromatography-tandem mass spectrometry
    Ding, Cun-Gang
    Zhou, Zhen
    Ge, Qing-Hua
    Zhi, Xiao-Jin
    Ma, Li-Li
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (02) : 132 - 138
  • [40] Simultaneous determination of methylephedrine and noscapine in human plasma by liquid chromatography-tandem mass spectrometry
    Zhu, L
    Chen, XY
    Zhang, YF
    Yu, HL
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (02): : 175 - 182