Carbon beam dosimetry intercomparison at HIMAC

被引:18
|
作者
Fukumura, A
Hiraoka, T
Omata, K
Takeshita, M
Kawachi, K
Kanai, T
Matsufuji, N
Tomura, H
Futami, Y
Kaizuka, Y
Hartmann, GH
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] Deutsch Krebsforschungszentrum, D-69120 Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 12期
关键词
D O I
10.1088/0031-9155/43/12/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To verify international uniformity in carbon beam dosimetry, an intercomparison programme was carried out at the heavy ion medical accelerator (HIMAC). Dose measurements with ionization chambers were performed for both unmodulated and 6 cm modulated 290 MeV/nucleon carbon beams. Although two different dosimetry procedures were employed, the evaluated values of absorbed dose were in good agreement. This comparison established a common framework for ionization chamber dosimetry between two different carbon beam therapy facilities.
引用
收藏
页码:3459 / 3463
页数:5
相关论文
共 50 条
  • [11] NEUTRON DOSIMETRY INTERCOMPARISON STUDIES
    SIMS, CS
    DICKSON, HW
    DICKSON, HW
    RADIATION PROTECTION DOSIMETRY, 1985, 10 (1-4) : 331 - 340
  • [12] An international neutron dosimetry intercomparison
    Gershenson Radiation Oncology Center, Harper Hospital, Wayne State University, 3990 John R, Detroit, MI 48201, United States
    MED. PHYS., 12 (2103-2104):
  • [13] REPORT ON THE BERKELEY DOSIMETRY INTERCOMPARISON
    LYMAN, JT
    BLATTMAN, H
    FESSENDEN, P
    LAM, KY
    MCDONALD, JC
    SMITH, AR
    VERHEY, L
    MEDICAL PHYSICS, 1980, 7 (04) : 425 - 425
  • [14] A physical dosimetry intercomparison for BNCT
    Riley, KJ
    Binns, PJ
    Greenberg, DD
    Harling, OK
    MEDICAL PHYSICS, 2002, 29 (05) : 898 - 904
  • [15] AN INTERNAL DOSIMETRY INTERCOMPARISON STUDY
    HUI, TE
    LOESCH, RM
    RADDATZ, C
    FISHER, DR
    MCDONALD, JC
    HEALTH PHYSICS, 1994, 67 (03): : 217 - 225
  • [16] INTERNATIONAL NEUTRON DOSIMETRY INTERCOMPARISON
    GEIGER, KW
    PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (02): : 315 - 316
  • [17] INTERNATIONAL INTERCOMPARISON OF NEUTRON DOSIMETRY
    CASWELL, RS
    GOODMAN, LJ
    COLVETT, RD
    RADIATION RESEARCH, 1974, 59 (01) : 174 - 174
  • [18] ''Hot particle'' intercomparison dosimetry
    Kaurin, DGL
    Baum, JW
    Charles, MW
    Darley, DPJ
    Durham, JS
    Scannell, MJ
    Soares, CG
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C28 - C30
  • [19] Dosimetry intercomparison using a 35-keV X-ray synchrotron beam
    Oves, Scott D.
    Hogstrom, Kenneth R.
    Ham, Kyungmin
    Sajo, Erno
    Dugas, Joseph P.
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : S121 - S125
  • [20] International intercomparison for criticality dosimetry:: The case of biological dosimetry
    Roy, L
    Buard, V
    Delbos, M
    Durand, V
    Paillole, N
    Grégoire, E
    Voisin, P
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 471 - 476