Restrictive factors of the measurement accuracy to estimate Blood Pressure with Pulse wave Transit Time

被引:0
|
作者
Chen, X. M. [1 ]
Li, Y. B. [1 ]
Zhang, Y. [1 ]
Deng, N. [1 ]
机构
[1] Tsinghua Univ, Inst Microelect, Beijing, Peoples R China
来源
BIOINFORMATICS AND BIOMEDICAL ENGINEERING: NEW ADVANCES | 2016年
关键词
ARRIVAL-TIME;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Pulse wave Transit Time (PTT) is a promising approach to achieve a continuous and non-invasive measurement of Blood Pressure (BP). However, compared with invasive and cuff-based methods, the PTT-based method is not accurate enough for some circumstances. In this paper, its major restrictive factors are investigated. According to the experimental results and analysis, the breathing rhythm and movement of subjects have an adverse impact on the detection of the pulse wave. In order to obtain better signals, noise should be eliminated and the time delay resulting from filters should be considered. The validity of PTT detection is a dominating factor of accuracy as well. Furthermore, the measured PTT is not the real PTT from the physiological perspective, which is mainly due to the acquisition difficulty of the pulse wave from the main artery. Finally, the influence of the regulatory mechanism is also analyzed.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 50 条
  • [41] Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
    Polinski, Artur
    Bujnowski, Adam
    Kocejko, Tomasz
    Wtorek, Jerzy
    2020 13TH INTERNATIONAL CONFERENCE ON HUMAN SYSTEM INTERACTION (HSI), 2020, : 289 - 294
  • [42] Correlation Study Between Blood Pressure And Pulse Transit Time
    Pereira, T.
    Sanches, R.
    Reis, P.
    Pego, J.
    Simoes, R.
    2015 IEEE 4TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2015,
  • [43] Validation of the Inverse Pulse Wave Transit Time Series as Surrogate of Systolic Blood Pressure in MVAR Modeling
    Giassi, Pedro, Jr.
    Okida, Sergio
    Oliveira, Mauricio G.
    Moraes, Raimes
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (11) : 3176 - 3184
  • [44] The key role of pulse wave transit time to predict blood pressure variation during anaesthesia induction
    Hu, Guoqiang
    Chen, Minjuan
    Wang, Xiaodan
    Chen, Lingyang
    Wang, Weijian
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (11)
  • [45] Mechanism affecting relationship between pulse wave transit time and blood pressure in isoflurane anesthetized dogs
    Ochiai, R
    Yamada, T
    Takeda, J
    Sugo, Y
    Soma, T
    Tanaka, R
    ANESTHESIA AND ANALGESIA, 1998, 86 (2S): : U145 - U145
  • [46] A NEW SYSTEM FOR MEASUREMENT OF THE PULSE TRANSIT TIME, THE PULSE WAVE VELOCITY AND ITS ANALYSIS
    Bereksi-Reguig, Anes.
    Bereksi-Reguig, F.
    Ali, A. Nait
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (01)
  • [47] Accuracy of pulse interval timing in ambulatory blood pressure measurement
    Kane, Sarah A.
    Blake, James R.
    McArdle, Frank J.
    Langley, Philip
    Sims, Andrew J.
    SCIENTIFIC REPORTS, 2016, 6
  • [48] Live Demonstration: Pulse Transit Time Measurement on a Modified Weighing Scale for Cuffless Blood Pressure Estimation
    Carek, Andrew M.
    Conant, Jordan
    Inan, Omer T.
    2016 IEEE SENSORS, 2016,
  • [49] A Calibration Method for Cuffless Continuous Blood Pressure Measurement using Gaussian Normalized Pulse Transit Time
    Xu, Yang
    Zhang, Weigong
    Wang, Dong
    Ping, Peng
    2018 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC): DISCOVERING NEW HORIZONS IN INSTRUMENTATION AND MEASUREMENT, 2018, : 152 - 156
  • [50] Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement
    Hoshide, Satoshi
    Yoshihisa, Akiomi
    Tsuchida, Fumihiro
    Mizuno, Hiroyuki
    Teragawa, Hiroki
    Kasai, Takatoshi
    Koito, Hitoshi
    Ando, Shin-ichi
    Watanabe, Yoshihiko
    Takeishi, Yasuchika
    Kario, Kazuomi
    HYPERTENSION RESEARCH, 2022, 45 (06) : 1001 - 1007