R290 (propane) and R600a (isobutane) as natural refrigerants for residential heat pump water heaters

被引:90
|
作者
Nawaz, Kashif [1 ]
Shen, Bo [1 ]
Elatar, Ahmed [1 ]
Baxter, Van [1 ]
Abdelaziz, Omar [1 ]
机构
[1] Oak Ridge Natl Lab, Bldg Equipment Grp, Oak Ridge, TN 37831 USA
关键词
Heat pump; Water heater; Hydrocarbons; Alternative refrigerants; AIR-CONDITIONING SYSTEM; HYDROCARBON MIXTURES; ALTERNATIVE REFRIGERANTS; DOMESTIC REFRIGERATORS; RETROFIT ASSESSMENT; REPLACE HFC-134A; PERFORMANCE; CFC12; DROP;
D O I
10.1016/j.applthermaleng.2017.08.080
中图分类号
O414.1 [热力学];
学科分类号
摘要
Growing awareness of the potential environmental impacts of various refrigerants has led to the phase down of hydrofluorocarbon (HFC) refrigerants and to initiatives replacing HFCs with hydrocarbons or other environmentally friendlier fluids. This study evaluated the performance of R290 (propane) and R600a (isobutane) as substitutes for R134a (a HFC) for heat pump water heating (HPWH). A component-based model (calibrated against the experimental data) was used to predict the performance of the HPWH system. Key performance parameters such as unified energy factor, first hour rating, condenser discharge temperature, thermal stratification in the water tank, and total refrigerant charge were investigated. Analysis results suggest that both alternative refrigerants could provide comparable system performance to that of the baseline system containing R134a, with one caveat. As a drop-in alternative, R290 was found to be a better substitute for R134a, whereas R600a is expected to provide similar performance if the compressor size is increased to provide similar heating capacity. Significant reductions in system charge and lower condenser discharge temperatures were identified as additional benefits. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:870 / 883
页数:14
相关论文
共 50 条
  • [31] 浅谈R290在大冷柜替代R600a的综合优势
    杨海线
    陶成
    高为民
    周翔
    徐建中
    蔡冬华
    日用电器, 2016, (01) : 42 - 44
  • [32] EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE
    Kandhaswamy, Karthikeyan
    Periasamy, Somasundaram
    Mayilsamy, Sivakumar
    Thangavel, Saravanakumar
    THERMAL SCIENCE, 2017, 21 : S515 - S522
  • [33] Thermodynamics studies on VCRS using refrigerant blends of R290, R600A, and R1234ZE
    Ravi, Govarthanan
    Adhimoulame, Kalaisselvane
    MULTISCALE AND MULTIDISCIPLINARY MODELING EXPERIMENTS AND DESIGN, 2024, 7 (05) : 4807 - 4818
  • [34] R744/R290/R600a混合工质热泵循环性能分析
    范晓伟
    徐菂
    王方
    制冷与空调, 2014, 14 (10) : 104 - 108
  • [35] Convective condensation of R600a, R290, R1270 and their zeotropic binary mixtures in horizontal tubes
    Moreira, Tiago Augusto
    Ayub, Zahid H.
    Ribatski, Gherhardt
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 130 : 27 - 43
  • [36] Thermodynamic analysis of the performance of a vapour compression refrigeration system, working with R290 and R600a mixtures
    Bolaji, B. O.
    Huan, Z.
    SCIENTIA IRANICA, 2013, 20 (06) : 1720 - 1728
  • [37] 新型环保混合制冷剂R290/R600a泄漏理论分析
    王青锋
    祁影霞
    曹睿
    王禹贺
    制冷技术, 2017, 37 (05) : 24 - 29
  • [38] Performance evaluation of a vapor injection refrigeration system using mixture refrigerant R290/R600a
    Hallak d'Angelo, Jose Vicente
    Aute, Vikrant
    Radermacher, Reinhard
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 65 : 194 - 208
  • [39] Energy comparison based on experimental results of a cascade refrigeration system pairing R744 with R134a, R1234ze(E) and the natural refrigerants R290, R1270, R600a
    Cabello, R.
    Andreu-Nacher, A.
    Sandhez, D.
    Llopis, R.
    Vidan-Falomir, F.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 148 : 131 - 142
  • [40] Experimental investigation on heat transfer of spray cooling with isobutane (R600a)
    Xu, Hongbo
    Si, Chunqiang
    Shao, Shuangquan
    Tian, Changqing
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 86 : 21 - 27